Product Description 
Scope 

This document describes the functional requirements and software features contained in the 
newly designed 

tres900 Enhanced GEN2 Reader 

hereon

 

known as

 tres900s

. This document 

lists the product specifications, as well as performance, and operational criteria. 

Summary 

The

 tres900

 is the brand name for a new line of 902~928 MHz RFID Readers and Tags. We 

are  a  U.S.  based  company  comprised  of  seasoned  RFID  professionals,  including  engineers, 
marketing, and distribution specialists. We have designed a product line that is ideally suited to 
the parking, supply chain, document tracking, and many other markets. We will be selling our 
products  through  Systems  Integrators,  Distribution  and  OEM  channels.  The 

tres900s

  is 

designed and manufactured in the USA to be an enhance version of the present 

tres900

 GEN2 

UHF Reader.  
The 

tres900s

 is designed to reduce the number of electronic components needed for a traditional 

Product. This is accomplished by using a custom integrated RF IC in place of many individual 
components. The product will offer the following features: 

 

Wiegand Output Format, multiple and custom formats, 3-wire  

 

EMI protected I/O lines, i.e. 2 each for Wiegand Output, 1 each for Trigger Input, 2 each for 
RS232, 2 each for RS485, etc.  

 

Reverse Polarity and Over Voltage protection on the input voltage 

 

Serial RS232 + RS485 Bi-directional, used for configuration and data output 

 

Buffer (100 mS to 60 sec), read tag + output tag + buffer tag, read and output after buffered time 

 

Timer read (10 mS to 1 sec), time between read and output data 

 

Multiple tag reads, single tag process the strongest RSSI read from tags 

 

LED flashing and Audio (Piezo) tone for power on and for a tag read 

 

Ethernet TCP/IP Output, daughter board (optional) 

 

Controller functionality w/relay, Site Code and ID range configurable 

 

SPI Flash IC to restore the program and store valuable settings 

Product Identity 

The 

tres900s 

will be given an engineering part number

.  

This part number prefix will start with 

the prefix number ‘900S’.  The firmware version will be ‘900S.0.0.xx’. Designated as: 

Model # 

Board rev 

Hardware rev  Serial Number 

900S 

xx 

xxxxx 

Reference Documents 

 

TBD 

Revision History 

 

Rev 01 04/13/19 - first draft by Rick L 

 

Rev 02 05/31/19 - changes made after evaluating prototype units 

 

Rev A 06/21/19 - first release after hardware updates and pre-production units 

Summary of Contents for 900s

Page 1: ...tres900s Operations Manual Revision A 6 21 2019 ...

Page 2: ...D INTERFACE 3 SERIAL RS232 RS485 3 TRIGGER MODE 3 POWER REQUIREMENTS 3 RELAY DESCRIPTION 3 SOFTWARE DESCRIPTION 3 OPTION FEATURE 4 DEFAULT TRES900S SETTINGS 4 CONNECTING TO TRES900S 4 WIRING DIAGRAM 4 LED Control 5 RS232 Control 5 RS485 Control 5 Earth 5 Power Connect 5 Relay Control 6 Trigger Control 6 Wiegand Control 6 TRES900S INTERFACE SETUP PROGRAM 6 UPPER LEFT TOOLS 7 CONTROL SECTION 7 Comm ...

Page 3: ...9 Relay 10 INDICATORS 10 LOG WINDOW 10 SPECIFICATIONS 11 READER INSTALLATION GUIDE 11 MOUNTING 11 INSTALLATION OVERVIEW 12 Trigger Function 12 Vertical Plane 12 Tag Vehicle Installation 12 Parallel Surfaces Rule 12 WIEGAND PANEL WIRING 13 SERIAL PORT RS232 WIRING 13 TROUBLESHOOTING GUIDE 13 WIRING GUIDE 14 LIMITED WARRANTY 15 ...

Page 4: ...product will offer the following features Wiegand Output Format multiple and custom formats 3 wire EMI protected I O lines i e 2 each for Wiegand Output 1 each for Trigger Input 2 each for RS232 2 each for RS485 etc Reverse Polarity and Over Voltage protection on the input voltage Serial RS232 RS485 Bi directional used for configuration and data output Buffer 100 mS to 60 sec read tag output tag b...

Page 5: ...t captures and processes tag data These devices are called readers or interrogators Readers are connected to the antenna and are connected to the RFID network infrastructure The Reader provides the energy of which a fraction is used to energize and wake up the tag The reach of the reader is determined by the design of the antenna both Tag and Reader and the power and configuration of the reader Th...

Page 6: ...ice because it also needs to communicate to a PC the setup parameters described later in this document Trigger Mode When the Installer puts the reader in trigger mode the reader will be put into IDLE mode this means the reader will not read and power consumption will be only 20mA Once the trigger is activated Trigger wire to ground it will take 6mS to start reading and outputting tag data again Th...

Page 7: ... Baud rate Protocol CR LF or OSDP and Address Incoming Tag ID output certain Facility Code 1 to 255 26 bit only range tag IDs Relay not Enabled Hold Time 100 mS to 3 seconds Indicators control LED Audio On Off software configurable Log window to monitor tags being read Update Firmware a feature to field flash the firmware Large Tag display window to read tag data at a long distance Default tres900...

Page 8: ... pin 5 of a 9 pin DIN ground RS485 Control This input output lines are used to control or be controlled by and RS485 device Line description 485B normally goes to the T R or 485B line 485A normally goes to the T R or 485A line and the 485 is the Ground line Earth Here you would connect an Earth ground to the reader instead of or still to the back panel of the reader Power Connect This is where you...

Page 9: ...our typical open collector Wiegand output terminals The WIG1 line goes to your DATA 1 D1 terminal on your controller the WIG0 line goes to your DATA 0 D0 terminal and the WIG is the Wiegand ground line tres900s Interface Setup Program In this portion of the document you will learn how to communicate and configure the tres900s Reader Hook up your tres900s and stated in the previous section connect ...

Page 10: ... use to connect to the tres900s here is where you will connect and communicate between your computer and to the tres900s You may first want to do a Device Manager lookup on your computer to see what COM PORT you are using to connect to the reader with Comm Upon power up the tres900s will search for available communication devices Select the appropriate Comm Port device from the drop down menu to c...

Page 11: ...Use RSSI this allows you to power a tag at maximum distance and only read if at a distance set This function is not fully working yet Timed Interval this is where you set the frequency of when you read tags minimum is 100mS and maximum read interval is 5 seconds Trigger Read Delay this is the setting to leave the reader on after the trigger is released minimum setting is 0 seconds and maximum is 1...

Page 12: ...ability to select then add a Facility Code and or ID number s This is where you select and set a facility code and all other facility codes read will be ignored If no facility code is selected all valid IDs will be outputted per user configuration If one Facility Code is selected only this Facility Code will be outputted per user configuration Use Facility Code when this box is selected a facility...

Page 13: ...eceived from the reader Hold Time this is the relay hold time you select between 100 mS 3 seconds When the relay is selected and a valid tag is read this time selection will keep the relay closed for that period of time This is handy when you want to control a device for a longer or shorter period of time after the valid tag is read and manipulated per user configuration Indicators Here is the sec...

Page 14: ...C 2Amp supplied Power Consumption peak 1 5 A max 5VDC 7 5 Watts Size 10 075 diameter 273 05mm x 3 85 thick 97 79mm Work Storage Temperature 4 F to 158 F 20 C to 70 C 40 F to 185 F 40 C to 85 C Certifications FCC Part 15 Subpart C and Canada RSS 210 Working Status Indication Audible Beeper external LED option Extra Features Options Relay External LED Multiple Wiegand Formats OSDP scrambled tag data...

Page 15: ...path Vertical Plane Vertical orientation is adjusted so as to aim the antenna at a spot about twenty feet 6 5 M on the road from the vehicle From this spot forward the detection area will increase as you get closer to the gate Tag Vehicle Installation A vertical orientation is the optimal orientation of the Tag in order of signal response performance If not a windshield tag then install the Tag us...

Page 16: ... tres900 Reader I have is Wiegand or serial or TCP IP Both Reader products have RS232 and one model has Wiegand and one has TCP IP The TCP IP model has a cat 5 cable with an 8 pin connector attached Q Tag data to panel is scrambled or Reader beeping and host not responding One or more of the Reader s wiring connections are incorrect Power down the receiver panel and verify the wiring connections a...

Page 17: ... without undue voltage losses All wire has a certain amount of resistance to the flow of current This resistance causes a drop in the voltage from the source to the load Voltage drops cause inefficiencies The wire sizing guide below provides the minimum wire size needed to limit voltage drops to 10 at a given distance in a 5vDC system POWER WIRE GUAGE W VA Amps 12 AWG 14 AWG 16 AWG 18 AWG 20 AWG 2...

Page 18: ...the Advanced Replacement invoice Repairs TRES liability under this warranty is limited to the repair or replacement of the defective product at the discretion of TRES If the returned product is tested and deemed to be fully functional it will be returned to the customer and a 50 00 evaluation fee will be assessed If the returned product can be repaired and the product is deemed to be covered by wa...