Revision A
6/21/2019
tres900s Operations Manual
Page
9
Wiegand Section
This is where you can modify your Wiegand settings. You normally would
not need to modify the Wiegand settings, but if you are running longer cable,
then you may have to. To modify the Wiegand timing, go to the Wiegand
Setting section of the Setup Software, then select the desired timing
parameters.
Output Mode,
you have the options of select to output both Wiegand and Serial or just the serial
data.
Output Buffer,
this allows you to select a Wiegand buffer from 100 mS…60 seconds. That
means, when the
tres900s
reads the first tag, this tag will be outputted thru either or both
Wiegand and serial, then store this tag into the buffer for time selected or until another valid tag
is read. If another tag is read before the timer times out, this tag data will be outputted, the buffer
will be reset, and this tag will be the new stored tag.
Pulse Width
, this allows you to modify the Wiegand Pulse Width, the specification is 20 µSec
to 100 µSec
Pulse Period
, this allows you to modify the Wiegand Pulse Period, the specification is 200 µSec
to 20000 µSec
IDs Section
In this section of the software, you will have the ability to select then add a
Facility Code and/or ID number(s). This is where you select and set a facility
code and all other facility codes read will be ignored. If no facility code is
selected, all valid IDs will be outputted per user configuration. If one Facility Code is selected,
only this Facility Code will be outputted per user configuration.
Use Facility Code
, when this box is selected, a facility code will be used to output only the
facility code selected. This means that you can read other tags with a different facility code and
they will not be outputted to your device. If you select the relay option, later in this document,
then only when this facility code is read, the relay will engage.
Facility Code
, here you will select the facility code
you want to output only. When you select between
0...255, only a tag read with this site code will be
outputted thru the Wiegand port. You can use the up
down scroll option or you can just enter the facility
code you want. Remember to send your changes to
the reader by using the ‘Send to reader’ option.
Tag IDs
, this is where you add, modify and delete ID
numbers. See larger picture on the right. First you
select the
Add
button on the right of the popup box
and another popup box will be displayed.
You can enter a single number or a range of numbers. The single number can be entered by just
entering a number in the highlighted box