WIRING DIAGRAM

ELECTRIC DEFROST - 230V

TTL

60Hz

23/06/17

T30-TTL-PDI-16

- 8 -

Summary of Contents for TTL Series

Page 1: ...Resources Service Parts Troubleshooting Warranty etc 15 As Built Service Parts List BACK High Medium and Low Temperature Applications 10 F 23 3 C or Above Box Temperature TTL Two Way Low Profile Evapo...

Page 2: ...rage space Dual refrigeration coils and two way air distribution reduces air velocities to minimize product dehydration Air enters through fan and discharges two ways out of each coil side Rugged heav...

Page 3: ...448 554 739 870 1372 1741 2611 R404A R507 850 1250 1700 2100 2800 3300 5200 6600 9900 249 366 498 615 821 967 1524 1934 2901 R22 810 1190 1620 2000 2700 3100 4900 6300 9400 237 348 473 584 780 919 144...

Page 4: ...1 2 1 5 15 70 0 65 0 81 15 60 530 4 6 5 8 15 021LE S1A 1 1 2 1 5 15 70 0 65 0 81 15 60 530 4 6 5 8 15 028LE S1A 1 1 2 1 5 15 70 0 65 0 81 15 60 0 60 0 75 15 30 750 6 5 8 2 15 033LE S1A 1 1 2 1 5 15 70...

Page 5: ...15ME S2A 1 0 7 0 9 15 60 0 24 0 30 15 50 530 2 3 2 9 15 020ME S2A 1 0 7 0 9 15 60 0 24 0 30 15 50 530 2 3 2 9 15 025ME S2A 1 0 7 0 9 15 60 0 24 0 30 15 50 530 2 3 2 9 15 032ME S2A 1 0 7 0 9 15 60 0 24...

Page 6: ...ER PLUGS REFER TO EVAPORATOR DATA PLATE FOR MOTOR QUANTITY MTR FAN TERMINALS MTR FAN MTR FAN SOLENOID VALVE EVAPORATOR NOTE 4 SPACE THERMOSTAT N C NOTE 4 LIQUID LINE 4 GND F FAN MOTOR POWER PLUGS REFE...

Page 7: ...OR EQUIVALENT 1 CIRCUIT 4 2 3 X N NOTE 3 BREAKER TM FUSE OR DEFROST HEATER L1 C T1 CONTACTOR CIRCUIT BREAKER NOTE 3 N GND L1 FUSE OR USING MAXIMUM 15A HEATER OVERCURRENT PROTECTION FOR ALL MODELS WIT...

Page 8: ...WIRING DIAGRAM ELECTRIC DEFROST 230V TTL 60Hz 23 06 17 T30 TTL PDI 16 8...

Page 9: ...8 7 8 479 4 1 2 114 14 1 8 359 17 3 4 451 9 3 4 248 12 6 5 7 020M 3 8 1 2 Flare 18 7 8 479 5 1 2 140 14 1 8 359 17 3 4 451 9 3 4 248 13 7 6 2 025M 3 8 1 2 Flare 18 7 8 479 5 1 2 140 14 1 8 359 17 3 4...

Page 10: ...F 23 5 8 600 C 7 5 8 194 23 3 4 603 DIMENSIONAL DATA 2 3 FAN Inches mm MODEL TTL Suc Conn TXV C D E F APPROX WEIGHT ID Sweat Inlet Size Inches mm Inches mm Inches mm Inches mm Lbs Kgs 060M 1 2 1 2 ODS...

Page 11: ...LL TXV Selections based on 90 100 F liquid MODEL TTL TD R404A R507 R448A R407A R407C R22 010M 10 HF 1 8 SC HF 1 4 HC 15 015M 10 HF 1 8 SC HF 1 4 HC 15 020M 10 HF 1 8 SC HF 1 4 HC 15 HF 1 4 SC 025M 10...

Page 12: ...595 20 3 135 4 940 6 270 9 405 RECOMMENDED EXPANSION VALVE SELECTION MEDIUM TEMPERATURE MODELS SPORLAN R404A MODEL TTL 009L 013L 017L 021L 028L BTUH VALVE BTUH VALVE BTUH VALVE BTUH VALVE BTUH VALVE E...

Page 13: ...laws LOCATION The evaporator is designed to be mounted to the ceiling of the box or cabinet Refrigeration piping and electrical connections are routed to the rear sides through the knock outs The uni...

Page 14: ...ost models AD Multiple fans have a junction terminal box for conduit connections INSTALLATION INSTRUCTIONS CONT D When fan delay thermostats are installed the fans may not start up until the coil temp...

Page 15: ...ng t rp com call 1 844 893 3222 x529 web t rp com parts email parts t rp com call 1 844 893 3222 x501 email orders t rp com call 1 844 893 3222 x501 email shipping t rp com call 1 844 893 3222 x503 TT...

Page 16: ...the manufacturer s policy of continuous product improvement we reserve the right to make changes without notice NATIONAL REFRIGERATION AIR CONDITIONING CANADA CORP 159 Roy Blvd Brantford Ontario Canad...