Trenton TTL Series Installation Instructions Manual Download Page 11

NOZZLE SELECTIONS

(FACTORY INSTALLED)

For all applications and refrigerants

RECOMMENDED EXPANSION VALVE SELECTION

MEDIUM TEMPERATURE MODELS

SPORLAN

DANFOSS

For medium temp. R-507, refrigerant designation changes from ‘S’ to ‘P’. 

 

 

  

 

Model TTL

Nozzle

009LE

NA

013LE

NA

017LE

L-1/4

021LE

L-1/3

028LE

L-1/2

033LE

L-1/2

052LE

L-1

066LE

L-1

099LE

L-1 1/2

MODEL

TTL

TD

R404A

R507

R448A

R407A

R407C

  

R22

 

010M

10

TUA-R404A-0-N

TUA-R22-0-N

15

TUA-R404A-1-N

015M

10

TUA-R404A-1-N

TUA-R22-0-N

15

TUA-R404A-2-N

TUA-R22-1-N

020M

10

TUA-R404A-2-N

TUA-R22-1-N

15

TUAE-R404A-3-N

TUAE-R22-2-N

025M

10

TUA-R404A-2-N

TUA-R22-1-N

15

TUAE-R404A-3-N

TUAE-R22-2-N

032M

10

TUAE-R404A-3-N

TUAE-R22-2-N

15

TUAE-R404A-4-N

TUAE-R22-3-N

038M

10

TUAE-R404A-3-N

TUAE-R22-3-N

15

TUAE-R404A-4-N

TUAE-R22-4-N

060M

10

TUAE-R404A-5-N

TUAE-R22-4-N

15

TUAE-R404A-6-N

TUAE-R22-5-N

077M

10

TUAE-R404A-5-N

TUAE-R22-5-N

15

TUAE-R404A-6-N

TUAE-R22-6-N

115M

10

TUAE-R404A-6-N

TUAE-R22-6-N

15

TUAE-R404A-8-N

TUAE-R22-7-N

ALCO

ALL TXV Selections based on 90-100°F liquid.

  

 

MODEL

TTL

TD

R404A

R507

R448A

R407A

R407C

  

R22

 

010M

10

HF-1/8-SC

HF-1/4-HC

15

015M

10

HF-1/8-SC

HF-1/4-HC

15

020M

10

HF-1/8-SC

HF-1/4-HC

15

HF-1/4-SC

025M

10

HF-1/4-SC

HF-1/4-HC

15

032M

10

HFESC-1/4-SC

HFESC-1/4-HC

15

HFESC-1/2-SC

HFESC-1/2-HC

038M

10

HFESC-1/4-SC

HFESC-1/2-HC

15

HFESC-1/2-SC

060M

10

HFESC-1/2-SC

HFESC-1/2-HC

15

HFESC-1-SC

HFESC-1-HC

077M

10

HFESC-1/2-SC

HFESC-1-HC

15

HFESC-1-SC

115M

10

HFESC-1-SC

HFESC-1-HC

15

HFESC-1 1/4-SC

HFESC-1 1/2-HC

MODEL

TTL

TD

R404A

R507

R448A

R407A

R407C

  

R22

 

010M

10

EGS-1/8-C

EGV-1/5-C

15

015M

10

EGS-1/6-C

EGV-1/5-C

15

020M

10

EGS-1/6-C

EGV-1/5-C

15

EGS-1/6-C

EGV-1/3-C

025M

10

EGS-1/6-C

EGV-1/5-C

15

EGV-1/3-C

032M

10

SBFSE-AA-C

SBFVE-AAA-C

15

SBFVE-AA-C

038M

10

SBFSE-AA-C

SBFVE-AAA-C

15

SBFSE-A-C

SBFVE-AA-C

060M

10

SBFSE-A-C

SBFVE-AA-C

15

077M

10

SBFSE-A-C

SBFVE-AA-C

15

SBFVE-A-C

115M

10

SBFSE-A-C

SBFVE-A-C

15

SBFSE-B-C

Model TTL

Nozzle

010MA/ME

NA

015MA/ME

NA

020MA/ME

NA

025MA/ME

NA

032MA/ME

L-1/4

038MA/ME

L-1/3

060MA/ME

L-1/2

077MA/ME

L-3/4

115MA/ME

L-1

TTL

60Hz

For R449A, use R448A data.

For R449A, use R448A data.

For R449A, use R448A data.

23/06/17

T30-TTL-PDI-16

- 11 -

Summary of Contents for TTL Series

Page 1: ...Resources Service Parts Troubleshooting Warranty etc 15 As Built Service Parts List BACK High Medium and Low Temperature Applications 10 F 23 3 C or Above Box Temperature TTL Two Way Low Profile Evapo...

Page 2: ...rage space Dual refrigeration coils and two way air distribution reduces air velocities to minimize product dehydration Air enters through fan and discharges two ways out of each coil side Rugged heav...

Page 3: ...448 554 739 870 1372 1741 2611 R404A R507 850 1250 1700 2100 2800 3300 5200 6600 9900 249 366 498 615 821 967 1524 1934 2901 R22 810 1190 1620 2000 2700 3100 4900 6300 9400 237 348 473 584 780 919 144...

Page 4: ...1 2 1 5 15 70 0 65 0 81 15 60 530 4 6 5 8 15 021LE S1A 1 1 2 1 5 15 70 0 65 0 81 15 60 530 4 6 5 8 15 028LE S1A 1 1 2 1 5 15 70 0 65 0 81 15 60 0 60 0 75 15 30 750 6 5 8 2 15 033LE S1A 1 1 2 1 5 15 70...

Page 5: ...15ME S2A 1 0 7 0 9 15 60 0 24 0 30 15 50 530 2 3 2 9 15 020ME S2A 1 0 7 0 9 15 60 0 24 0 30 15 50 530 2 3 2 9 15 025ME S2A 1 0 7 0 9 15 60 0 24 0 30 15 50 530 2 3 2 9 15 032ME S2A 1 0 7 0 9 15 60 0 24...

Page 6: ...ER PLUGS REFER TO EVAPORATOR DATA PLATE FOR MOTOR QUANTITY MTR FAN TERMINALS MTR FAN MTR FAN SOLENOID VALVE EVAPORATOR NOTE 4 SPACE THERMOSTAT N C NOTE 4 LIQUID LINE 4 GND F FAN MOTOR POWER PLUGS REFE...

Page 7: ...OR EQUIVALENT 1 CIRCUIT 4 2 3 X N NOTE 3 BREAKER TM FUSE OR DEFROST HEATER L1 C T1 CONTACTOR CIRCUIT BREAKER NOTE 3 N GND L1 FUSE OR USING MAXIMUM 15A HEATER OVERCURRENT PROTECTION FOR ALL MODELS WIT...

Page 8: ...WIRING DIAGRAM ELECTRIC DEFROST 230V TTL 60Hz 23 06 17 T30 TTL PDI 16 8...

Page 9: ...8 7 8 479 4 1 2 114 14 1 8 359 17 3 4 451 9 3 4 248 12 6 5 7 020M 3 8 1 2 Flare 18 7 8 479 5 1 2 140 14 1 8 359 17 3 4 451 9 3 4 248 13 7 6 2 025M 3 8 1 2 Flare 18 7 8 479 5 1 2 140 14 1 8 359 17 3 4...

Page 10: ...F 23 5 8 600 C 7 5 8 194 23 3 4 603 DIMENSIONAL DATA 2 3 FAN Inches mm MODEL TTL Suc Conn TXV C D E F APPROX WEIGHT ID Sweat Inlet Size Inches mm Inches mm Inches mm Inches mm Lbs Kgs 060M 1 2 1 2 ODS...

Page 11: ...LL TXV Selections based on 90 100 F liquid MODEL TTL TD R404A R507 R448A R407A R407C R22 010M 10 HF 1 8 SC HF 1 4 HC 15 015M 10 HF 1 8 SC HF 1 4 HC 15 020M 10 HF 1 8 SC HF 1 4 HC 15 HF 1 4 SC 025M 10...

Page 12: ...595 20 3 135 4 940 6 270 9 405 RECOMMENDED EXPANSION VALVE SELECTION MEDIUM TEMPERATURE MODELS SPORLAN R404A MODEL TTL 009L 013L 017L 021L 028L BTUH VALVE BTUH VALVE BTUH VALVE BTUH VALVE BTUH VALVE E...

Page 13: ...laws LOCATION The evaporator is designed to be mounted to the ceiling of the box or cabinet Refrigeration piping and electrical connections are routed to the rear sides through the knock outs The uni...

Page 14: ...ost models AD Multiple fans have a junction terminal box for conduit connections INSTALLATION INSTRUCTIONS CONT D When fan delay thermostats are installed the fans may not start up until the coil temp...

Page 15: ...ng t rp com call 1 844 893 3222 x529 web t rp com parts email parts t rp com call 1 844 893 3222 x501 email orders t rp com call 1 844 893 3222 x501 email shipping t rp com call 1 844 893 3222 x503 TT...

Page 16: ...the manufacturer s policy of continuous product improvement we reserve the right to make changes without notice NATIONAL REFRIGERATION AIR CONDITIONING CANADA CORP 159 Roy Blvd Brantford Ontario Canad...

Reviews: