THS2085 Installation Guide
5-1
Trenton Systems, Inc.
Chapter 5 -
Chassis Specifications
E
NVIRONMENTAL
Temperature
Operating
5
C to 35
C typical
Storage
-20
C to 70
C
Cold Excursion Temp
-40
C for up to sixteen hours
Relative Humidity
5% to 90%, non-condensing
Specific operating temperature ranges for the THS2085 are dependent on the number of option cards and
other system components installed. Extended operating temperature CPUs resulting in a system’s
achievable operating temperature range higher than what is stated here may be available for use on the
system host inside the THS2085. The reverse can also be true in that a system subcomponent could have a
lower operating temperature range that could lower the system’s overall operating temperature range.
Contact Trenton for more details.
E
LECTRICAL
Line Voltage
110-240VAC
Line Frequency
50-60Hz
Power Consumption
450W typical, 650W max.
P
HYSICAL
Approximate Dimensions
(W x H x D)
19” x 3.5” x 18.2”
48.3cm x 8.9cm x 46.2cm
Net Weight
23.8 lbs. (10.8 kg)
(includes chassis, SHB, backplane, and 1U removable PS)
A
GENCY
A
PPROVALS
UL
(THS2085-001 system configuration)
UL listed product listed in file #E208896-A6-UL dated
2016-07-26
Environmental
(THS2085-001 system configuration)
IEC 60721-3-3:2002 including Class 3K3, 3Z3, 3Z4,
3M4 and 3S2
IEC 60721-3-2:1997 including Class IE23 and 2M3
CE – Application of Council Directive:
89/336/EEC - EMC Directive
(THS2085-001 system configuration)
IEC 55022: 2008 Class A, IEC 61000-3-2:2014 , IEC
61000-3-3: 2013, IEC 61000-4-2: 2008, IEC 61000-4-
3: 2006 + A1: 2007 + A2: 2010, IEC 61000-4-4: 2012,
IEC 61000-4-5: 2014, IEC 61000-4-6: 2013, IEC
61000-4-8: 2009 & IEC 61000-4-11: 2004
FCC Class B, Subpart 15
(THS2085-001 system configuration)
EN 55032: 2015 guidelines for Radiated & Conducted
Emissions