Chassis Specifications 

 

E

NVIRONMENTAL

 

 

Temperature 

 

 

Operating 

5

C to 35

C typical 

 

Storage 

-20

C to 70

        Cold Excursion Temp    

-40

C for up to sixteen hours 

Relative Humidity 

5% to 90%, non-condensing 

 
Specific operating temperature ranges for the THS2085 are dependent on the number of option cards and 
other system components installed.  Extended operating temperature CPUs resulting in a system’s 
achievable operating temperature range higher than what is stated here may be available for use on the 
system host inside the THS2085.  The reverse can also be true in that a system subcomponent could have a 
lower operating temperature range that could lower the system’s overall operating temperature range.  
Contact Trenton for more details.  

E

LECTRICAL

 

Line Voltage 

110-240VAC 

Line Frequency 

50-60Hz 

Power Consumption 

450W typical, 650W max. 

 

P

HYSICAL

 

Approximate Dimensions 
(W x H x D) 

19” x 3.5” x 18.2” 
48.3cm x 8.9cm x 46.2cm 

Net Weight 

23.8 lbs. (10.8 kg) 

(includes chassis, SHB, backplane, and 1U removable PS)

 

 
A

GENCY 

A

PPROVALS

 

UL 

(THS2085-001 system configuration)

 

UL listed product listed in file #E208896-A6-UL dated 
2016-07-26 

Environmental 

(THS2085-001 system configuration)

 

IEC 60721-3-3:2002 including Class 3K3, 3Z3, 3Z4, 
3M4 and 3S2 
IEC 60721-3-2:1997 including Class IE23 and 2M3  

CE – Application of Council Directive:   
         89/336/EEC - EMC Directive 

(THS2085-001 system configuration)

 

IEC 55022: 2008 Class A, IEC 61000-3-2:2014 , IEC 
61000-3-3: 2013, IEC 61000-4-2: 2008,  IEC 61000-4-
3: 2006 + A1: 2007 + A2: 2010,  IEC 61000-4-4: 2012, 
IEC 61000-4-5: 2014, IEC 61000-4-6: 2013,  IEC 
61000-4-8: 2009 & IEC 61000-4-11: 2004 

FCC Class B, Subpart 15 

(THS2085-001 system configuration)

 

EN 55032: 2015 guidelines for Radiated & Conducted 
Emissions 

 

Summary of Contents for HDEC Series

Page 1: ...THS2085 HDEC Series 2U RACKMOUNT COMPUTER No THS2085 xxx Revision A INSTALLATION GUIDE Publication No 8402085 03396...

Page 2: ...ailure is caused by accident acts of God or other causes beyond the control of Trenton Trenton reserves the right to make changes or improvements in any product without incurring any obligation to sim...

Page 3: ...s associated with any particular installation Trenton Systems cannot assume responsibility or liability for actual system use based on the examples and diagrams No patent liability is assumed by Trent...

Page 4: ...R 2 SYSTEM DIMENSIONS LAYOUT 2 1 SYSTEM DIMENSIONS 2 1 CHAPTER 3 INSTALLATION INSTRUCTIONS 3 1 ENVIRONMENTAL CONSIDERATIONS 3 1 RACK MOUNTING 3 1 RACKMOUNT INSTRUCTIONS 3 1 SLIDE RAIL INSTALLATION 3 1...

Page 5: ...ques when moving and installing the system When removing or installing boards and sub components keep these components in their static shielded bag and or packaging until you are ready to for componen...

Page 6: ...S AIRFLOW When installing the chassis ensure that a minimum free air space is available around the system The installation should have a minimum of 4 6 inches 101 152mm behind the chassis and 7 8 inch...

Page 7: ...and power supply combination System Model Number Backplane Model SHB Model Number Description of Backplane SHB and System Power Supply Combination THS2085 000 HDB8227 HEP8225 Backplane 1 SHB Slot and...

Page 8: ...im Line R W DVD 4 67CFM system fans Consult with Trenton for available storage drives and optical media drives compatible with the THS2085 SHB BATTERY CAUTION Risk of explosion if the system host boar...

Page 9: ...al clearance PCI Express option card slot locations THS2085 001 Rear View 2U Fixed mount Power Supply Configuration Front View THS2085 002 Rear View 1U Removable Power Supply Configuration 19 0 48 3cm...

Page 10: ......

Page 11: ...ACKMOUNT INSTRUCTIONS A Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient There...

Page 12: ...are bag number S 047 0 includes 10 mounting rail to computer chassis screws 1 mounting hardware bag number S 017 1 includes 36 rail frame to 19 rack mounting screws 10 nuts 10 flat washer 2 Take one o...

Page 13: ...il mounting hardware 9 The rubber bumper on the outside portion of slide rails are to be located toward the rear of the 19 rack 10 Refer to figure 3 and attach two rail frames each to the outside port...

Page 14: ...he rackmount enclosure You should have another person help you lift and slide the chassis into the enclosure 17 You should hear and audible click when the rail stop hooks on the slide engage with the...

Page 15: ...located at the rear of the system An over current protection device shall protect each power cord To connect AC power to the computer 1 Establish a chassis to earth ground connection to the THS2085 ch...

Page 16: ......

Page 17: ...THS2085 are designed for easy access Make sure you have a front chassis clearance of at least 6 152mm to remove or install system cards COOLING FANS The four 60mm cooling fans of the THS2085 are attac...

Page 18: ...rrent limits for the 5V 3 3V and 12V outputs from the system power supply are 32A 32A and 65A respectively The system s power monitoring circuits will shut the system down if these maximum current lim...

Page 19: ...for more details ELECTRICAL Line Voltage 110 240VAC Line Frequency 50 60Hz Power Consumption 450W typical 650W max PHYSICAL Approximate Dimensions W x H x D 19 x 3 5 x 18 2 48 3cm x 8 9cm x 46 2cm Ne...

Page 20: ......

Page 21: ...THS2085 Installation Guide 6 1 Trenton Systems Inc Chapter6 CertificationDocuments CE Certificate of Compliance...

Page 22: ...THS2085 Installation Guide Trenton Systems Inc 6 2 FCC Part 15 Subpart B Certificate of Compliance...

Reviews: