THS2085 Installation Guide
3-5
Trenton Systems, Inc.
C
ONNECTING
AC
P
OWER
When using the THS2085 with the redundant power supply option, a single-phase power source providing
110-240VAC at 50 to 60Hz must be connected to
each
AC input power outlet located at the rear of the
chassis. The fixed-mount version of the THS2085 just has one AC input power outlet to connected to the
single-phase power source. Power must be available at all available three-pin AC input receptacles located
at the rear of the system. An over-current protection device shall protect each power cord.
To connect AC power to the computer:
1.
Establish a chassis to earth ground connection to the THS2085 chassis.
2.
Connect the AC power cords to all available AC receptacles.
3.
Connect the plug end of the power cords into the main outlets.
NOTE:
The maximum current limits for the +5V, +3.3V and +12V outputs from the system power supply
are 32A, 32A and 65A respectively. The system’s power monitoring circuits will shut the system down if
these maximum current limits are drawn from the power supply.
THS2085-000 with Redundant Power Supply
THS2085-001/002 with Fixed-mount Power Supply