Cable Diagnostics Test
Tools > Cable Diagnostics
The switch provides a basic cable diagnostic tool in the GUI for verifying the pairs in
copper cabling and estimated distance for troubleshooting purposes.
1. Log into your switch
management page (see “
Access your switch management page
on page 7).
2. Click on
Tools
and click on
Cable Diagnostic
.
3. Click on the
Start
button to run the cable diagnostic.
The results will be displayed in the
Cable Diagnostic Table
.
•
Test Results:
Displays the diagnostic results for each pair in the cable. One of the
following cable status parameters is displayed:
o
Healthy:
There is no problem detected with the cable.
o
Open:
There is an open wire within the cable.
o
Short:
Two wires are shorted together within the cable.
•
Clear:
The
Clear
button can be used to clear the Cable Diagnostic test results.
Enable IEEE 802.3az Power Saving Mode
Tools > IEEE 802.3az EEE
The IEEE 802.3 EEE standard defines mechanisms and protocols intended to reduce the
energy consumption of network links during periods of low utilization, by transitioning
interfaces into a low-power state without interrupting the network connection. The
transmitted and received sides should be IEEE802.3az EEE compliance. By default, the
switch disabled the IEEE 802.3az EEE function. Users can enable this feature via the
IEEE802.3az EEE setting page.
1. Log into your switch
management page (see “
Access your switch management page
on page 7).
2. Click on
Tools
and click on
IEEE 802.3az EEE
3. Click the
IEEE 802.3az EEE Status
drop-down list and select
Enabled
to enable the
power saving feature and click
Apply
to save the settings.