background image

-

 3 

-

LED Indicators

1

5

The function of each LED is described in the table below

Green

Power 1 is off

Off

Power 1 is on, and device is functioning normally

PWR1

Green

Power 2 is off

Off

Power 2 is on, and device is functioning normally

PWR2

Green

System fail, fail LED will also be turned on

Off

System is running normal

STATE

Green

OT Defense console sync is disabled

Off

OT Defense Console Sync (ODC) is enabled and ODC is connected

MGMT

Green

High-Availability feature is tunred off

Off

High-Availability feature is tunred on

HA

Green

Hardware or system fault

Off

LED will be turned on when USB is plugged in

USB

Red

System is running normal

Off

System fail which includes hardware and software

Fail

Reset type

Description

Press and hold the reset button for 2 to 10 seconds. The STATE LED

will begin to blink on a 1-second pattern, which means the system is

rebooting.

Press and hold the reset button for more than 10 seconds. The STATE

LED will begin to blink every half-second, which means the system is

resetting itself to factory defaults.

Reboot System

Restore Factory 

Default Settings

Reset to factory default setting

1

6

The reset button for the EdgeIPS Pro-2096 is located on the front panel.

SECURED BY

SLOT1

SLOT3

SLOT2

SLOT4

1-2

3-4

5-6

7-8

9-10

11-12

BP

1

2

3

4

PORT

5

6

7

8

9

10

11

12

13-14

15-16

17-18

19-20

21-22

23-24

13

14

15

16

17

18

19

20

21

22

23

24

1-2

3-4

5-6

7-8

9-10

11-12

BP

1

2

3

4

PORT

5

6

7

8

9

10

11

12

13-14

15-16

17-18

19-20

21-22

23-24

13

14

15

16

17

18

19

20

21

22

23

24

1-2

3-4

5-6

7-8

9-10

11-12

BP

1

2

3

4

PORT

5

6

7

8

9

10

11

12

13-14

15-16

17-18

19-20

21-22

23-24

13

14

15

16

17

18

19

20

21

22

23

24

1-2

3-4

5-6

7-8

9-10

11-12

BP

1

2

3

4

PORT

5

6

7

8

9

10

11

12

13-14

15-16

17-18

19-20

21-22

23-24

13

14

15

16

17

18

19

20

21

22

23

24

PWR1

PWR2

STATE

MGMT

HA

USB

FAIL

RESET

MGMT

HA

MR

OIOI

SECURED BY

SLOT1

SLOT3

1-2

3-4

5-6

7-8

9-10

11-12

BP

1

2

3

4

PORT

5

6

7

8

9

10

11

12

13-14

15-16

17-18

19-20

21-22

23-24

13

14

15

16

17

18

19

20

21

22

23

24

BP

PORT

1-2

3-4

5-6

7-8

9-10

11-12

BP

1

2

3

4

PORT

5

6

7

8

9

10

11

12

13-14

15-16

17-18

19-20

21-22

23-24

13

14

15

16

17

18

19

20

21

22

23

24

BP

PORT

PWR1

PWR2

STATE

MGMT

HA

USB

FAIL

RESET

MGMT

HA

MR

OIOI

-

 2 

-

Summary of Contents for EdgelIPS Pro-2096

Page 1: ...1 22 23 24 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 10 11 12 BP 1 2 3 4 PORT 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 13 14 15 16 17 18 19 20 21 22 23 24 1 2 3 4 5 6 7 8 9 1...

Page 2: ...n 53 or above Safari version 10 1 or above Google Chrome version 63 or above Laptop with Ethernet Port RJ 45 Type User Name admin Password txone Deployment Scenario and System Operation Mode 4 Deploym...

Page 3: ...stem is resetting itself to factory defaults Reboot System Restore Factory Default Settings Reset to factory default setting 1 6 The reset button for the EdgeIPS Pro 2096 is located on the front panel...

Page 4: ...096 when you take it out of the box If you need to reattach the Rail attachment plate to the EdgeIPS Pro 2096 make sure the stiff metal spring is oriented towards the top as shown in the following pic...

Page 5: ...5 Step4 Step5 Step6 Release safety lock before mounting Push the safety lock forward to secure Retainer is in fully open position Press trigger down to release the slides from locking 4...

Page 6: ...to 240 AC power cord to the power socker which is connected to the EdgeIPS Pro device If the power is supplied properly the Power LED will glow steadily The power input location and pin definition ar...

Page 7: ...o 192 168 127 100 After that connect the PC and EdgeIPS Pro 2096 using an Ethernet cable Open a web browser on your PC and type https 192 168 127 254 into the address bar A pop up window will open to...

Page 8: ...management IP address for EdgeIPS Pro Confiture GatewayAddress of the EdgeIPS Pro Gateway Configure DNS setting of the EdgeIPS Pro DNS Configure Network VLAN ID of the device Network VLAN ID Use the...

Page 9: ...hardware bypass enabled Turn on RED Port Pair hardware bypass disabled Right LED 1 Gbps LINK ACT on 1 Gbps link Port Pair hardware bypass normal Turn on Green No Light The EdgeIPS Pro appliance cannot...

Page 10: ...iewing messages during the boot sequence or for debugging system boot issues To connect the console cable remove the protective cover on the port Serial Console Port Cable Pinouts The initial configur...

Reviews: