20
EN
minipool
Phantom
PR1
Alarms
ALARMS
NOTIFICATIONS
Screen
displayed
DESCRIPTION OF THE PROBLEM
POSSIBLE SOLUTIONS
Ll
Water level alarm
(notification)
Problem description:
the notification is activated if the water level in-
side the compensation tank is below the minimum for more than three
seconds. The display will show the message "LL" alternating with the
temperature, the functions remain enabled, the system will start filling
the minipool to restore the levels (see paragraph on minipool filling on
page15 (Phantom PRO) or page21 (Phantom SPA)
The notification is activated when a number of people leave the bathtub
at the same time (the system automatically restores the level by activat-
ing the fill function).
FER
Water level
sensors alarm
(alarm)
Problem description:
the alarm is activated if there is a malfunction of
the level sensors, especially when the system detects the maximum level
but not the minimum level.
Solutions:
try to reset the system by switching off the pool for about 30
seconds. If the alarm does not reset contact the Manufacturer.
Al1
Water fill timeout
alarm
(alarm)
Problem description
: the alarm is activated when filling is in progress,
if the minimum level is not reached within 90 minutes from the start of
the filling.
Solutions:
The alarm resets only by switching off the minipool and turn-
ing it back on after about 30 seconds.
The main causes of what has been described are attributable to:
1
Water supply closed or blocked (make sure the valves are open and the
solenoid valves are not dirty).
2
Water supply with low pressure (make sure that the minipool's sup-
ply pressure is between 1.5 and 3 bar).
3
Leaks in the bathtub's pipes (make sure that there are no leaks in
the bathtub).
If the minipool does not reactivate after checking these possible problems
(after having reset the control unit by disconnecting and reconnecting the
power supply), contact the Manufacturer to request assistance.
Al2
Water level time-
out alarm
(alarm)
Problem description:
the alarm is activated when the maximum level is
not reached within 30 minutes from the minimum to the maximum sen-
sor both during the filling phase and during the recovery of the water
level in the tank.
Solutions:
The alarm resets only by switching off the minipool and turn-
ing it back on after about 30 seconds.
The main causes of what has been described are attributable to:
1
Water supply closed or blocked (make sure the valves are open and the
solenoid valves are not dirty).
2
Water supply with low pressure (make sure that the minipool's sup-
ply pressure is between 1.5 and 3 bar).
3
Leaks in the bathtub's pipes (make sure that there are no leaks in
the bathtub).
4
Check that there are no water leaks in the drain of the minipool
(make sure that there is no dirt in the drain valves).
Al3
Emptying timeout
alarm
(alarm)
Problem description:
when the minipool is being emptied, if the mini-
mum level is not reached within 120 min the system stops, the display
shows the fixed message "Al3".
Solutions:
1
make sure that the drain is not obstructed and that the drain valves
open correctly.
2
Try switching off the minipool and then on again after about 30
seconds.
If the alarm does not reset contact the Manufacturer.