5
EN
2
CHECKING MINIPOOL INTEGRITY
After having removed the minipool from the packing, check its integrity.
Check:
• That there is no visible structural damage.
• That there are no cracks in the surface of the minipool or in the outer covering (cracks due to incorrect transport or
support are not covered by the warranty).
• The correct position of the sleeves and pipes.
• That any ties are not loosened.
If you notice any anomalies, do not proceed with the installation but rather promptly contact the Manufacturer.
Preliminary operations
1
PREPARATIONS AND CHOICE
OF POSITION
The pre-installation sheet supplied at the time
of purchase provides all the information neces-
sary for a correct preparation of the installation
environments.
Before installing the minipool, check that everything
has been prepared.
Find below a quick checklist, for
complete information always refer to the pre-installation
sheet.
Check that:
• A platform or a recess (in the case of recessed installa-
tions) of reinforced concrete, with a minimum thickness
of 10 cm, has been created, perfectly flat and suitable
for supporting the weight of the minipool and the
people within.
• Ø15 cm vents have been installed to ensure proper
ventilation of the technical compartment
• Drainage grating around the perimeter has been in-
stalled to help preserve the equipment and the struc-
ture (even for indoor installations).
• Non-slip flooring has been installed in the area around
the minipool.
• For a recessed installation, a technical inspection port
measuring at least 50 cm wide has been prepared on
all sides of the minipool.
• The connections to the water supply and electrical grid
have been made in compliance with current regulations
in force in the country of installation.
• A drain, a gate valve (to shut off the supply water) and
drain valves have been installed (to empty the bathtub
at the end of the season).
• A water softener has been installed (upstream of the
minipool) if the water has a high degree of hardness.
• For outdoor recessed versions, the walls have been
insulated to protect against the cold.
More information
OUTDOOR INSTALLATION
Preparations
: in cold areas, to avoid possible damage
due to freezing, it is recommended to provide valves
for the total drainage of the pipes, to be positioned at
their lowest point.
To run the pipes and electric cables from the main elec-
trical panel to the minipool underground ducts must
be used and adequately protected against freezing by
using insulation. It is also recommended to add drain-
age points in them to prevent standing water.
Choice of position
: take into account the proximity of
trees or hedges, and note that debris (e.g., leaves) can
cause damage to the equipment over time that is not
covered by warranty and make maintenance more ex-
pensive and frequent. It is also recommended to always
install flooring around the minipool, possibly anti-slip.
INDOOR INSTALLATION
Preparations
: in the area used to access the minipool
it is recommended to install anti-slip flooring. The
evaporation of water in the minipool in the presence
of high internal temperatures can generate very high
levels of humidity in the environment.
To avoid this problem, provide good natural or forced
ventilation in the installation environment and, if nec-
essary, a dehumidification system. Damage caused by
this phenomenon is not covered by the manufacturer
warranty.
Choice of position
: Always take into account the size
of the minipool: narrow passages, doors and steps can
be an obstacle to its transport to the desired place.
minipool