treesse Phantom PR1 Installation Manual Download Page 5

5

EN

2

CHECKING MINIPOOL INTEGRITY

After having removed the minipool from the packing, check its integrity.

Check:
•  That there is no visible structural damage.
•  That there are no cracks in the surface of the minipool or in the outer covering (cracks due to incorrect transport or 

support are not covered by the warranty).

•  The correct position of the sleeves and pipes.
•  That any ties are not loosened.

If you notice any anomalies, do not proceed with the installation but rather promptly contact the Manufacturer.

Preliminary operations

1

PREPARATIONS AND CHOICE 

OF POSITION

The pre-installation sheet supplied at the time 

of purchase provides all the information neces-

sary for a correct preparation of the installation 

environments.

Before installing the minipool, check that everything 

has been prepared.

 Find below a quick checklist, for 

complete information always refer to the pre-installation 
sheet.
Check that:
•  A platform or a recess (in the case of recessed installa-

tions) of reinforced concrete, with a minimum thickness 
of 10 cm, has been created, perfectly flat and suitable 
for supporting the weight of the minipool and the 
people within.

•  Ø15 cm vents have been installed to ensure proper 

ventilation of the technical compartment

•  Drainage grating around the perimeter has been in-

stalled to help preserve the equipment and the struc-
ture (even for indoor installations).

•  Non-slip flooring has been installed in the area around 

the minipool.

•  For a recessed installation, a technical inspection port 

measuring at least 50 cm wide has been prepared on 
all sides of the minipool.

•  The connections to the water supply and electrical grid 

have been made in compliance with current regulations 
in force in the country of installation.

•  A drain, a gate valve (to shut off the supply water) and 

drain valves have been installed (to empty the bathtub 
at the end of the season).

•  A water softener has been installed (upstream of the 

minipool) if the water has a high degree of hardness.

•  For outdoor recessed versions, the walls have been 

insulated to protect against the cold.

More information

OUTDOOR INSTALLATION

Preparations

: in cold areas, to avoid possible damage 

due to freezing, it is recommended to provide valves 
for the total drainage of the pipes, to be positioned at 
their lowest point.
To run the pipes and electric cables from the main elec-
trical panel to the minipool underground ducts must 
be used and adequately protected against freezing by 
using insulation. It is also recommended to add drain-
age points in them to prevent standing water.

Choice of position

: take into account the proximity of 

trees or hedges, and note that debris (e.g., leaves) can 
cause damage to the equipment over time that is not 
covered by warranty and make maintenance more ex-
pensive and frequent. It is also recommended to always 
install flooring around the minipool, possibly anti-slip.

INDOOR INSTALLATION

Preparations

: in the area used to access the minipool 

it  is  recommended  to  install  anti-slip  flooring.  The 
evaporation of water in the minipool in the presence 
of high internal temperatures can generate very high 
levels of humidity in the environment.
To avoid this problem, provide good natural or forced 
ventilation in the installation environment and, if nec-
essary, a dehumidification system. Damage caused by 
this phenomenon is not covered by the manufacturer 
warranty.

Choice of position

:  Always take into account the size 

of the minipool: narrow passages, doors and steps can 
be an obstacle to its transport to the desired place.

minipool

 

Phantom

Summary of Contents for Phantom PR1

Page 1: ...Phantom PR1 SP1 minipool Installation manual...

Page 2: ...ead this manual carefully before installing it The Treesse team is always available for any information or request for assistance that may be required during installation GRUPPO TRE S s p a Telephone...

Page 3: ...___11 WATER HARDNESS__________________________________________________________________________11 WATER ALKALINITY_________________________________________________________________________11 5 ELECTRICA...

Page 4: ...follow the information provided in this manual can cause damages injuries or fatal accidents and null and void the warranty During the installation of the minipool do not place objects inside it even...

Page 5: ...ith current regulations in force in the country of installation A drain a gate valve to shut off the supply water and drain valves have been installed to empty the bathtub at the end of the season A w...

Page 6: ...desired place of installation Movement must be carried out using personal protective equipment e g gloves safety shoes etc and taking all the necessary safety precau tions for those involved and to no...

Page 7: ...ce If it was not possible to provide a technical inspec tion port on all sides of the minipool a pneu matic lift is available OPTIONAL to be request ed from the Manufacturer in order to simplify futur...

Page 8: ...efore installation it is recommended to carefully read the safety warnings at the beginning of this manual and to always operate in perfect physical and mental condition The installer qualified and au...

Page 9: ...ection to an exchanger optional if present see following page The following pages will provide detailed explanations of how to perform these preparations EXAMPLES OF OUTDOOR INDOOR MINIPOOL INSTALLATI...

Page 10: ...0 40 I N O U T I N O U T IN OUT OUT IN Electrical connection Circulator not supplied Exchanger not supplied Room for the electrical con nections The exchanger means the device that heats water in this...

Page 11: ...of alkalinity range between 80 mg L and 125 mg L 8 F 12 5 F Values outside of this range can more easily cause variations of the pH Instead alkalinity within the range noted makes it possible to buff...

Page 12: ...d If the minipool is installed outdoors provide an adequate thermal insulation of the pipes It is the plumber s responsibility to choose the type of materials to be used Connect the drain of the floor...

Page 13: ...reaking capacity equal to 60A or in any case adequate for the absorption of the bathtub Controlled by a differential switch no larger than 30mA The control unit s power supply cable must be of the H05...

Page 14: ...l codes and that they can guarantee a perfect seal verification to be carried out after filling the minipool Electrical connections are made correctly in accordance with local and national codes and t...

Page 15: ...L2 maximum level will be triggered stopping Before filling once again check the quality of the water supply This is very important for the well being of the users and for the long life of the minipool...

Page 16: ...lpool function stops the key returns to white and the temperature is shown again on the display If not switched off manually the function stops auto matically after 20 minutes 4 WATER TEMPERATURE ADJU...

Page 17: ...is automati cally activated to drain the airpool system pipes During emptying of the minipool the only enabled function is chromatherapy To stop the emptying test disconnect the power supply to the b...

Page 18: ...is suspended and heating and filtering is re enabled and will be reactivated 10 minutes after the last user function has been switched off If the temperature set point is changed during the SILENCE fu...

Page 19: ...the Manufacturer FLO No flow alarm notification Problem description the notification protects the heater and the recirculation pump from running in the event of potential danger It is activated when...

Page 20: ...olenoid valves are not dirty 2 Water supply with low pressure make sure that the minipool s sup ply pressure is between 1 5 and 3 bar 3 Leaks in the bathtub s pipes make sure that there are no leaks i...

Page 21: ...21 EN minipool Phantom PR1 Notes Notes...

Page 22: ...tes 1 MINIPOOL FILLING Filling is carried out by following the figures on the side follow the instructions for your keypad Filling takes place from the bottom of the bathtub and once it has finished t...

Page 23: ...he bathtub in sequence in the presence of the owner to verify proper operation WATER TEMPERATURE ADJUSTMENT Pressing the or keys will vary the setting of the water temperature by 0 5 C the standard va...

Page 24: ...u must turn off and reactivate the function Hold the Light key for two seconds to turn off the function If not switched off manually the function stops automatically after three hours The function can...

Page 25: ...till active then press the key emptying in progress is indicated by the flashing blue key The emptying of the minipool can be activated at any time Emptying lasts about 120 minutes and for the entire...

Page 26: ...thtub and switch it on again after 30 seconds If the problem persists verify that the connection with the control unit is correct and has not been tampered with Otherwise contact the Manufacturer Fl N...

Page 27: ...functions remain enabled the system will start filling the minipool to restore the level see the section on filling the minipool on page 15 ZEN ACTIVE PR1 or page19 ZEN ACTIVE SP1 The notification is...

Page 28: ...seals are worn Check the tightness or replace the seals The water of the minipool does not become clear Most likely the pH of the water supply is incorrect and so algae grows For more information see...

Page 29: ...29 EN Mount the wood or laminate resin panels as shown in the figures below Decorative panels 2 3 1 1 3 2 minipool Phantom...

Page 30: ...seful if the minipool is installed outdoors In this case it might be useful to anchor it with lashing straps in order to prevent the wind from moving it or blowing it off Covering Maximum care has bee...

Page 31: ...31 EN minipool Phantom Notes Notes...

Page 32: ...tom installation PR1 SP1 Edition 05 2020 www gruppotreesse it GRUPPO TRE S s p a 01036 Nepi VT Italy S S Cassia km 36 400 Settevene industrial area tel 39 0761 527242 fax 39 0761 527223 info gruppotre...

Reviews: