FIRST RUN

With the bathtub full, recirculation active and ozone ac-
tive, start in sequence all the functions of the bathtub in 
the presence of the owner to verify proper operation:

1

 BLOWER

 

The minipool can be equipped with a blower motor 
that drives the nozzles on the bottom;  

 

Pressing the 

1

 key starts the nozzles on the seat  

(default duration 20 minutes). 

 

The blower function on the seat can be started even 

if the whirlpool is running.

 When the 

1

 key is pressed again, the blower func-

tion stops, the key returns to white and the tempera-
ture is shown again on the display.

 

If not stoppedmanually , the function stops automati-
cally after 20 minutes.

2

  PERIMETRAL PLUS WHIRLPOOL

 

Pressing the 

2

 key activates the 

PLUS whirlpool 

function on the lumbar area

 and the corresponding 

key turns blue.

 The 

 icon appears on the display for six seconds 

and then is replaced by the temperature. When the 

key is pressed again, the whirlpool function stops, the 

key returns to white and the temperature is shown 

again on the display.

 

If not switched off manually, the function stops auto-
matically after 20 minutes. 

3

  PERIMETER WHIRLPOOL (BACK AND LEGS) 

 The whirlpool is divided into two areas: one on the 

back and one on the legs.

The functions can only be activated when the 

water  level  is  sufficient.  When  EMPTYING,  the 

whirlpool is deactivated.

 

Pressing the 

3

 key activates the 

whirlpool function 

on the back and legs

 and the corresponding key 

turns blue. The 

 icon appears on the display for 

six seconds and then is replaced by the temperature. 

When the key is pressed again, the whirlpool function 

stops, the key returns to white and the temperature 

is shown again on the display.

 

If not switched off manually, the function stops auto-
matically after 20 minutes.

4

  WATER TEMPERATURE ADJUSTMENT 

 

When one of the two keys 

+

 or 

-

 is pressed once, 

the display shows the current setting (default 35°C) and 
the two keys are illuminated with a strong blue light.

 

From the second press on, the displayed value is 
increased or decreased by one degree at a time 
depending on the key pressed (range from 15°C to 
40°C). 

 

After six seconds of inactivity with the keys or if an-

other key is pressed, the adjustment function will end 

and the two keys will return to white, memorising the 

First run

new setting. 

 

The  function  will  activate  the  heater  (flashing  degree 
character) with the objective of heating and maintaining 
the water temperature at the set value (+/- 0.5°C).

5

 CHROMATHERAPY 

 

Pressing the light 

5

 key will activate a sequence of 

16 colours that will vary in an automatic intermittence 
(for 2 hours by default): 

the light 

5

 key and the 

+

 

and 

-

 keys turn blue and the symbol 

+

 will ap-

pear on the display for 6 seconds. 

 

During this time you can press the 

+

 or 

-

 key to 

manually select a colour that you want to remain fixed: 

the light key 

5

 will remain blue, while the 

+

 and 

-

 

keys will turn white again:  at this time it is no longer 

possible to change colour.

 

To once again manually select the colour, press the 
light key 

5

 again and select the desired colour within 

six seconds with the 

+

 or 

-

 key.

 

Once you have selected a fixed colour, to return to the 
automatic sequence you must turn off and reactivate 
the function. 

 

To stop the function hold the 

 key pressed for 

about three seconds. The key will turn white again 

and the temperature will reappear on the display.



OK

OK

3”

1

7

8

9

10

2

5

3

6

4

Submenu 

page

Main page

Summary of Contents for Phantom PR1

Page 1: ...Phantom PR1 SP1 minipool Installation manual...

Page 2: ...ead this manual carefully before installing it The Treesse team is always available for any information or request for assistance that may be required during installation GRUPPO TRE S s p a Telephone...

Page 3: ...___11 WATER HARDNESS__________________________________________________________________________11 WATER ALKALINITY_________________________________________________________________________11 5 ELECTRICA...

Page 4: ...follow the information provided in this manual can cause damages injuries or fatal accidents and null and void the warranty During the installation of the minipool do not place objects inside it even...

Page 5: ...ith current regulations in force in the country of installation A drain a gate valve to shut off the supply water and drain valves have been installed to empty the bathtub at the end of the season A w...

Page 6: ...desired place of installation Movement must be carried out using personal protective equipment e g gloves safety shoes etc and taking all the necessary safety precau tions for those involved and to no...

Page 7: ...ce If it was not possible to provide a technical inspec tion port on all sides of the minipool a pneu matic lift is available OPTIONAL to be request ed from the Manufacturer in order to simplify futur...

Page 8: ...efore installation it is recommended to carefully read the safety warnings at the beginning of this manual and to always operate in perfect physical and mental condition The installer qualified and au...

Page 9: ...ection to an exchanger optional if present see following page The following pages will provide detailed explanations of how to perform these preparations EXAMPLES OF OUTDOOR INDOOR MINIPOOL INSTALLATI...

Page 10: ...0 40 I N O U T I N O U T IN OUT OUT IN Electrical connection Circulator not supplied Exchanger not supplied Room for the electrical con nections The exchanger means the device that heats water in this...

Page 11: ...of alkalinity range between 80 mg L and 125 mg L 8 F 12 5 F Values outside of this range can more easily cause variations of the pH Instead alkalinity within the range noted makes it possible to buff...

Page 12: ...d If the minipool is installed outdoors provide an adequate thermal insulation of the pipes It is the plumber s responsibility to choose the type of materials to be used Connect the drain of the floor...

Page 13: ...reaking capacity equal to 60A or in any case adequate for the absorption of the bathtub Controlled by a differential switch no larger than 30mA The control unit s power supply cable must be of the H05...

Page 14: ...l codes and that they can guarantee a perfect seal verification to be carried out after filling the minipool Electrical connections are made correctly in accordance with local and national codes and t...

Page 15: ...L2 maximum level will be triggered stopping Before filling once again check the quality of the water supply This is very important for the well being of the users and for the long life of the minipool...

Page 16: ...lpool function stops the key returns to white and the temperature is shown again on the display If not switched off manually the function stops auto matically after 20 minutes 4 WATER TEMPERATURE ADJU...

Page 17: ...is automati cally activated to drain the airpool system pipes During emptying of the minipool the only enabled function is chromatherapy To stop the emptying test disconnect the power supply to the b...

Page 18: ...is suspended and heating and filtering is re enabled and will be reactivated 10 minutes after the last user function has been switched off If the temperature set point is changed during the SILENCE fu...

Page 19: ...the Manufacturer FLO No flow alarm notification Problem description the notification protects the heater and the recirculation pump from running in the event of potential danger It is activated when...

Page 20: ...olenoid valves are not dirty 2 Water supply with low pressure make sure that the minipool s sup ply pressure is between 1 5 and 3 bar 3 Leaks in the bathtub s pipes make sure that there are no leaks i...

Page 21: ...21 EN minipool Phantom PR1 Notes Notes...

Page 22: ...tes 1 MINIPOOL FILLING Filling is carried out by following the figures on the side follow the instructions for your keypad Filling takes place from the bottom of the bathtub and once it has finished t...

Page 23: ...he bathtub in sequence in the presence of the owner to verify proper operation WATER TEMPERATURE ADJUSTMENT Pressing the or keys will vary the setting of the water temperature by 0 5 C the standard va...

Page 24: ...u must turn off and reactivate the function Hold the Light key for two seconds to turn off the function If not switched off manually the function stops automatically after three hours The function can...

Page 25: ...till active then press the key emptying in progress is indicated by the flashing blue key The emptying of the minipool can be activated at any time Emptying lasts about 120 minutes and for the entire...

Page 26: ...thtub and switch it on again after 30 seconds If the problem persists verify that the connection with the control unit is correct and has not been tampered with Otherwise contact the Manufacturer Fl N...

Page 27: ...functions remain enabled the system will start filling the minipool to restore the level see the section on filling the minipool on page 15 ZEN ACTIVE PR1 or page19 ZEN ACTIVE SP1 The notification is...

Page 28: ...seals are worn Check the tightness or replace the seals The water of the minipool does not become clear Most likely the pH of the water supply is incorrect and so algae grows For more information see...

Page 29: ...29 EN Mount the wood or laminate resin panels as shown in the figures below Decorative panels 2 3 1 1 3 2 minipool Phantom...

Page 30: ...seful if the minipool is installed outdoors In this case it might be useful to anchor it with lashing straps in order to prevent the wind from moving it or blowing it off Covering Maximum care has bee...

Page 31: ...31 EN minipool Phantom Notes Notes...

Page 32: ...tom installation PR1 SP1 Edition 05 2020 www gruppotreesse it GRUPPO TRE S s p a 01036 Nepi VT Italy S S Cassia km 36 400 Settevene industrial area tel 39 0761 527242 fax 39 0761 527223 info gruppotre...

Reviews: