Setting Up the Web Server 

1.

 

Select 

Menu

 button 

OK(M/

)

 to select the 

Comm Menu

 

2.

 

If there is an Admin user defined, it will prompt you to login with an Admin account. You login using the 
identification defined for an Admin User (ID or scan card, and/or scan the fingerprint). The default admin 
password is 54321. 

3.

 

Select 

Menu

 button 

OK(M/

)

 to select 

Add a Web Setup

 

4.

 

Enter the webserver address (IP mode) or as a URL (URL mode). Change the WebServer spin control using 
the left and right arrows to change the value. At ‘WebServer’, enter the TCS Push server host address 
(IPmode) or URL address.  
You need to enter the server IP address for example in SaaS 

http://174.129.220.45/iclock/

, the IP address 

should be 174.129.220.45. 
 

Summary of Contents for US10C

Page 1: ...Administrator Manual US10C Time Clock Enterprise Time Attendance and Workforce Management February 2020 Version 1 0 1...

Page 2: ...ts under copyright no part of this document may be reproduced in whole or in part without the express written permission of TreeRing Workforce Solutions Inc Unless otherwise noted the example companie...

Page 3: ...I FI Static Information Setup 8 Wired Connection 8 Adding Users for the US10C ID Clocks 9 Tips to Punch In Out 12 Clocking In and Out 12 Setting Up the Web Server 14 Setting up the Device in Time Cloc...

Page 4: ...0C Ethernet Clock with Proximity Badge Reader US10C ID Ethernet Clock with Proximity Badge Reader and Biometric Fingerprint Reader The device supports all standard TreeRing Time punch types up to 10 d...

Page 5: ...nch break Lunch In Press when returning from lunch Note If a Minimum Lunch Time is configured for your organization and you try to punch in for a Lunch Return before that time is up you will be preven...

Page 6: ...nt on several factors including router capabilities office physical operating environment interference and device Note Do not plug the WIFI device into an Ethernet port Doing so will disable the WIFI...

Page 7: ...Press the Menu button OK M 4 Select Wireless 5 Press the Menu button OK M 6 Select your Wireless Network 7 Press the Menu button OK M 8 The Password Setup screen will appear 9 If you have your USB Dri...

Page 8: ...Clock 10 Use the navigation keys to select Load Password If the USB device loads the password correctly you will see your network password hidden in the text field 11 Save the password into the device...

Page 9: ...sfully connecting to your wireless network you should see one of the following icons in the top right hand corner of your main screen These icons indicate the strength of your wireless signal 13 Go ba...

Page 10: ...7 Administrator Manual US10C Time Clock Note A reboot may be required after this step...

Page 11: ...the Comm Menu 2 Select WIFI Setup 3 Navigate to IP Address and switch it to Manu short for manual 4 Navigate to Point IP and press the Menu button OK M 5 Enter the IP Addr NetMask and Gateway 6 Press...

Page 12: ...ers to be defined with up to three possible identifications Proximity card RFID Card Fingerprint s Password With advanced configuration of the clock users can be required to provide multiple authentic...

Page 13: ...OK M 7 Press Menu button OK M to enroll another finger or ESC to return to the previous menu PWD is not used at this time You can record up to 10 unique fingerprints 8 Select a finger with the most v...

Page 14: ...core on the fingerprint reader during enrollment 11 Enter employee card ID number under ID NO 12 Scroll down to the Enroll FP button and press Menu button OK M 13 When prompted scan your finger If the...

Page 15: ...ayed on the screen The time of day is displayed on a clock in the center of the screen with the date and day of week shown below The punch type selection is changed by scrolling with the or keys throu...

Page 16: ...tabase from enroll and or template sync download US10C ID or validation download US10C w validation enabled the device will display Not Enrolled Note If you are prompted to select a department use the...

Page 17: ...can card and or scan the fingerprint The default admin password is 54321 3 Select Menu button OK M to select Add a Web Setup 4 Enter the webserver address IP mode or as a URL URL mode Change the WebSe...

Page 18: ...Check the desired punch types Time Clock Options and Timezone Offset Since the clock communicates with the server every 30 seconds the Communication Threshold should be set to a small value like 5 min...

Page 19: ...p up boxes remain on the display before timing out and closing Most prompts and messages can be closed immediately by pressing the ESC key 12 Press Save Changes Fingerprint thresholds should be left a...

Page 20: ...display Digital 0 Black background digital time date with punch mode buttons Digital time date no buttons Digital 3 to 99 Slide show background with punch mode buttons Digital time date no buttons Ro...

Page 21: ...further information Click the Save Changes button below the tabs to save your changes Utilizing TCS Events TCS utilizes the following events to communicate with the US10C US10C ID Event Name Purpose...

Page 22: ...19 Administrator Manual US10C Time Clock Getting Assistance Contact our Technical Support Department with questions and troubleshooting assistance at 1 855 861 4381 option 2 or support treeringws com...

Reviews: