Modellbau Lindinger GmbH
Alte-Post-Str. 14 A-4591 Molln e-Mail:
www.lindinger.at
VELINEON POWER SYSTEM • 1
VxL-3s Setup and Operation
VxL-3s LEd codes and Protection Modes
•
Solid Green
: VXL-3s power on light. Low-Voltage Detection is ON (LiPo setting).
•
Solid Red
: VXL-3s power on light. Low-Voltage Detection is OFF (NiCad/NiMH setting).
•
Fast Blinking Red
: Thermal Shutdown Protection Stage 1. If the motor has lower than normal power and the
VXL-3s is hot, the VXL-3s has entered
Stage 1 Thermal Shutdown Protection
to guard against overheating caused
by excessive current flow. If the motor has no power and the VXL-3s is very hot, the VXL-3s has entered
Stage 2
Thermal Shutdown Protection
and has automatically shut down. Let the VXL-3s cool. Make sure your model is
properly geared for the conditions.
•
Slow Blinking Red
(with Low-Voltage Detection on): The VXL-3s has entered
Low-Voltage Protection
. When
the battery voltage begins to reach the minimum recommended discharge voltage threshold for LiPo battery
packs, the VXL-3s will limit the power output to 50% throttle. When the battery voltage attempts to fall below the
minimum threshold, the VXL-3s will shut down all motor output. The LED on the speed control will slowly blink
red, indicating a low voltage shutdown. The VXL-3s will stay in this mode until a fully charged battery is connected.
•
Alternating; Blinks Red then Green
: If the motor has no power, the VXL-3s has entered
Over Voltage Protection
.
If a battery with too high voltage is used, the VXL-3s will go into a failsafe mode.
Warning
: If input voltage exceeds
approximately 20-volts, the ESC may be damaged. Do not exceed 12.6 maximum peak input voltage.
•
Blinking Green
: The VXL-3s is indicating the transmitter Throttle Trim is incorrectly set. Adjust the Throttle Trim to
the middle “0” setting.