18 Fireplace
Insert
Installation
(for qualified installers only)
© Travis Industries
100-01342
4131101
Surround Panel Installation
Width
Height
Part#
Standard Size
38” (966mm)
25” (635mm)
96100409
The surround panel is installed after the
insert is in place with the flue attached.
Make sure to route the power cord and
rheostat wires through the notch in the
panel.
NOTE: The surround panel is not required.
If the fireplace opening is small enough, you
may wish to use the face only (see
dimensions below).
Face Removal
WARNING
: Unplug or disable power
to the appliance prior to removing the
face.
1) Open the door and lift it off its
hinges.
2) Pull the bypass all the way
forward. Unscrew the bypass rod
from the bypass yoke (make sure
to detach the handle and rod as
one piece).
3) Unscrew the air control rod from
the air control.
4) The face uses hooks to hang in
place. Lift the face up and pull
back to remove. Take care to
prevent damage to the wiring
(disconnect if necessary).
See the instructions included with the
face for full details.
FACE SIZING: 30” Wide, 21.5” Tall
When installing, lift the panel over this flange.