Gas/Pellet Remote Thermostat
SKU 99300689
Page 3 of 8
3/7/12 - 17601682
© Travis Industries, Inc.
Gas Fireplace Receiver Placement
Place the receiver on the fireplace base near the front of the fireplace. Route the receiver wires to a location
near the on/off switch. Route the power cord to a location near the power inlet (see “Power Cord Adapter
Installation” below).
FOR THE 21 TRV:
Remove the control cover and place the receiver to the right of the gas control valve.
WARNING
: Make sure the power cord and receiver
wires do not contact the blower (if applicable) or firebox
(or other hot surface). Use lock-ties if necessary.
Place the receiver in a location
near the front of the fireplace.
Power Cord Adapter Installation
On newer gas appliances power may be drawn directly from the appliance AC circuit. Connect the receiver
power cord to the power cord adapter then attach to the power harness on the appliance (see illustration
below). If using a blower you will need to disconnect the blower power lead and attach it to the power cord
adapter.
Power Adapter
(included with remote)
Ground
120 VAC
Power In
Optional
Blower
Lead
6V AC Adapter for
Fireplace Burner Control
Remote Receiver
Accent
Light Lead