Stove
Installation
(for qualified installers only)
13
© Travis Industries
100-01165
4110919
Insert with Direct
Connection (Z.C.
Fireplace)
NOTE
:
Direct connections require
installation of an airtight
block-off plate or damper
adapter (see "Block-off
Plate Installation" on page
11).
NOT ALLOWED IN
CANADA
Figure 10
Block-off plate or
damper adapter
Stainless steel
chimney connector
must Extend 1' past
the block-off plate.
Combustible Mantle
See the section
"Insert Placement
Requirements" for
minimum clearances
and hearth required.
Surround Panels
NOTE: This installation may be
used with a masonry or zero
clearance fireplace. This
illustration depicts a zero
clearance insert, all requirements
in the section "Zero Clearance
Fireplace Requirements" must be
fulfilled prior to installation.
Z.C. (Metal) firebox
Optional
Telescoping Legs
No modification to the firebox
of the z.c. fireplace is allowed.
Damper must
be removed