6
Routine Maintenance
Care of the Display Canopy (required as needed)
Cleaning the Condenser (required approx. every 90-days)
1. Disconnect power supply.
2. Remove the screws securing canopy brackets (see
fig. 1).
3. Lift curved canopy section(s) towards front, out of
mounting bar bracket, and up and away from the
cabinet (see fig. 2).
NOTE
On 78” units the two canopy sections are
connected by a plastic H-Channel.
4. Lift out canopy side pieces.
5. Wash all canopy parts in hot, soapy water.
6. Allow to air dry and wipe away any water spots using
a clean, dry cloth.
7. Reassemble by reversing steps 1 thru 4.
Cleaning the condenser is critical to insuring proper
performance and long compressor life.
1. Disconnect power supply.
2. Open the compressor access door.
3. Vacuum or brush coil fins clear of any dust or debris
present.
4. Close the compressor access door.
5. Restore power.
WARNING!
Use of ammonia or ammonia containing cleaners, such
as windex, will blur and/or craze the plexiglass canopy.
fig. 1
fig. 2
fig. 1
fig. 2