TRANSTEK TeleCuff Gen 2 User Manual Download Page 4

6

5

CAUTION

INTRODUCTION

INTRODUCTION

* The device contains sensitive electronic components.To avoid measurement errors, avoid taking blood 

pressure measurements near a strong electromagnetic field radiated interference signal or electrical fast 

transient/burst signal.

mains.Do not position the equipment so that it is difficult to reach or disconnect.

* Wireless communication equipment, such as wireless home network devices, mobile phones, cordless 

measurements. A minimum distance of 1 foot (30 cm) should be kept from such devices during a 

telephones and their base stations,walkie-talkies may cause interference that may affect the accuracy of

measurement.

* You can use this device to take your own measurement, no third-party operator is required.

* Please use the device under the environment which is provided in the user manual. Otherwise, the 

performance and lifetime of the device will be impacted and reduced.

* The device may require up to 30 minutes to warm up / cool down from the minimum / maximum storage 

temperature before it is ready for use.

* Warning: Do not touch output of the batteries/adapter and the user simultaneously.

* Adapter is specified as a part of ME EQUIPMENT.

* Warning: The power cord is considered the disconnect device for isolating this equipment from supply 

* Warning: Do not use this device if you are allergic to polyester, nylon, or plastic. 

* Warning: Only use accessories approved by manufacturer. Using unapproved accessories might cause 

damage to the unit and injure users.

* Warning: If you experience discomfort during a measurement, such as pain in the arm or other complaints, 

* No calibration is required within two years of reliable service. 

* Do not attempt to repair the unit yourself if it malfunctions. Only have repairs carried out by authorized 

service centers.

of use,by retesting the requirements in limits of the error of the cuff pressure indication and air leakage 

press the Power button immediately to release the air from the cuff.

* At the request of authorized service personnel, circuit diagrams, component part lists, descriptions, and 

calibration procedures will be made available by the manufacturer or distributor.

* It is recommended that the performance should be checked after repair, maintenance, and every two years 

(testing at least at 50 mmHg and 200 mmHg).

* Warning: Do not use the device while under maintenance, or being serviced.

dust and direct sunlight. Never place any heavy objects on it.

strangulation if used improperly.

Do not use alcohol, benzene, or other harsh chemicals.

Do not wash teh cuff in a washing machine or dishwasher!

typical service life is 10000 times.

*Make sure the rubber tube of the cuff is not squeezed,stretched,or kinked during storage.

*Warning:Keep the device,cuff,and batteries away from children as they may pose a risk of choking or

* Dispose of accessories, detachable parts, and the device according to the local guidelines. 

* The service life of the cuff may vary by the frequency of washing,skin condition,and storage state.The

* This device is intended for indoor use.

* This device is portable, but it is not intended for use during patient transport.

* This device is not suitable for continuous monitoring during medical emergencies or operations.

* This device is intended for no-invasive measuring and monitoring of arterial blood pressure. It is not intended 

for use on extremities other than the arm, or for any purpose other than obtaining a blood pressure 

measurement.

* This device is for adults. Do not use this device on neonates or infants. Do not use it on children unless 

otherwise instructed by a medical professional.

*The effectiveness of this device has not been established for use:

   -on the women in pregnant, including pre-eclamptic, patients,

   -on patients with implanted, electrical devices, such as cardiac pacemakers, defibrillators,

   -on users with common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation,

   -on users with peripheral arterial disease,

 * Do not apply the cuff on an arm that has an intravenous drip or a blood transfusion attached.

 * Warming: Do not kink,fold,stretch,compress,or otherwise deform the tube during measuring, as the cuff

   -on users undergoing intravascular therapy, or with arteriovenous (AV) shunt.

Consult a medical professional before use.

* Do not use this device for diagnosis or treatment of any health problem or disease. Contact your physician if 

you have or suspect any medical problem. Do not change your medications without the advice of your 

physician or health care professional.

* If you are taking medication, consult your physician to determine the proper time to measure your blood 

pressure.

* This device may be used only for the intended use described in this manual, the manufacturer shall have no 

liability for any incidental, consequential, or special damages caused by misuse or abuse.

* Report any unexpected operation or events to the manufacturer.

pressure might continuously increase, which could prevent blood  flow and result injury.

* Warning: Taking blood pressure measurements too frequently could disrupt blood circulation and cause 

injuries.

for irritation.

treatment, i.e. intra-vascular access or intra-vascular therapy or an arteriovenous (A-V) shunt, which could 

disrupt blood circulation and cause injuries.

could temporarily stop functioning if you try to use them at the same time.

* Please check that the operation of the device do not result in prolonged impairment of patient blood 

circulation. 

constant pressure >15 mmHg for more than 3 minutes) might lead to bruising and discolored skin.

* Warning: Do not use this device with high-frequency (HF) surgical equipment at the same time.

* Warning: This device is not AP/APG equipment. Do not use the  device where flammable anesthetic are

present, or in environments mixture with air of with oxygen or nitrous oxide.

*Do not place the cuff on the arm on the same side of a mastectomy(especially when lymph nodes have been

removed).it is recommended to take measurements on the unaffected side.

*Do not wrap the cuff on the same arm to which another monitoring device is applied.One or both devices

CAUTION

Summary of Contents for TeleCuff Gen 2

Page 1: ...0 Guangdong Transtek Medical Electronics Co Ltd Zone A No 105 Dongli Road Torch Development District 528437 Zhongshan Guangdong China User Manual Pro Cellular Blood Pressure Monitor TMB 2092 G TeleCu...

Page 2: ...c pressure What is the standard blood pressure classi cation Why does my blood pressure uctuate throughout the day Is the result the same if measuring on the righe arm ABOUT BLOOD PRESSURE TROUBLESHOO...

Page 3: ...vice Date of Manufacture Recyclable Indicates the need for the user to consult the instructions for use for important cautionary information such as warnings and precautions that cannot for a variety...

Page 4: ...ency of washing skin condition and storage state The This device is intended for indoor use This device is portable but it is not intended for use during patient transport This device is not suitable...

Page 5: ...nt icon loose when measuring will appear if the cuff is not wrapped or wrapped too Cuff wearing detection icon Indicates the current measurement mode is Triple Mode and which measurement progress it i...

Page 6: ...e the AC adapter authorized by the manufacturer Please unplug the adapter to depart from the using utility power when you nish the measurement 6V 1A Do not use new and used batteries together Do not u...

Page 7: ...w rst Note B turned off If unsuccessful the monitor will stop searching and enter the standby mode This device is equipped with function of Measurement Reminder Contact Customer Support to enable or d...

Page 8: ...ill appear on the LCD Adjust the zero point In ating and measuring Display the measured result When the TRIPLE MODE button is located on OFF the monitor is under the Single Measurement mode When the m...

Page 9: ...start the second measurement after 60 seconds 3 Then it will repeat the steps to nish the third measurement When three measurements are done the LCD will display the average of 3 readings Tip If the m...

Page 10: ...dry place and avoid the sunshine Avoid intense shaking and collisions Using wet cloths to remove dirt Avoid washing the cuff Avoid touching water clean it with a dry cloth in case Avoid dusty and uns...

Page 11: ...e range Please note that only a physician can tell whether your blood pressure value has reached a dangerous point Blood Pressure Category Normal Elevated High Blood Pressure Hypertension Stage 1 High...

Page 12: ...K THIS REMEDY No power Low Battery Error message Display can not light up Batteries are exhausted Replace with new batteries Install the batteries or plug in the adapter properly Replace with new batt...

Page 13: ...ressure 0mmHg 299mmHg SYS 60 mmHg 230 mmHg DIA 40 mmHg 130 mmHg Pulse value 40 199 beat minute Device Classi cation Expected Lifetime Battery Powered Mode Internally Powered ME Equipment AC Adaptor Po...

Page 14: ...45 90 135 180 225 270 and 315 0 UT 1 cycle and 70 UT 25 30 cycles Single phase at 0 0 UT 250 300 cycle Conduced RF IEC61000 4 6 3 V 0 15 MHz 80 MHz 6 V in ISM and amateur radio bands between 0 15 MHz...

Page 15: ...TE Band 13 17 Pulse modulation 217 Hz GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 Pulse modulation 18 Hz GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulation 217 Hz Bluetoot...

Reviews: