background image

TS-­‐NX/CL   

INSTALLATION   MANUAL

   

   

Page   50   

TS-NX/CL PROGRAMMING TABLE 

Name 

Default Value 

Short Description 

TZEA 

Time zone end interval 

BTN1 

Empty 

Button 2, Telephone number 1 

BTN2 

Empty 

Button 2, Telephone number 2 

BTN3 

Empty 

Button 2, Telephone number 3 

BTN4 

Empty 

Button 2, Telephone number 4 

BTN5 

Empty 

Button 2, Telephone number 5 

RTNB 

25 

Ring time, Button 2 

SDNB 

DTMF number to send 

SDDB 

Delay for DTMF to send 

TZSB 

Time zone start interval 

TZEB 

Time zone end interval 

 

 

 

 

Table 22: TS-NX/CL default settings.  

 

Summary of Contents for TS-NX/CL

Page 1: ...TS NX CL GSM DOOR ENTRY UNIT W CODELOCK Installation Manual ...

Page 2: ......

Page 3: ...DE 34 9 9 CLIP 35 9 10 EVENT LOGING 38 9 11 SPECIAL SMS COMMANDS 39 10 PRINT OUT OF THE PARAMETERS 41 10 1 RECEIVE ALL PARAMETERS PALL 41 10 2 CHECK SW REVISION PSW 41 10 3 CHECK SIGNAL QUALITY PSQ 41 10 4 RECEIVE TELEPHONE NUMBERS PTN 41 10 5 RECEIVE LINKS PLN 41 10 6 RECEIVE INPUT PARAMETERS PIN 42 10 7 RECEIVE INPUT FILTER VALUE PID 42 10 8 RECEIVE OUTPUT FILTER VALUE POD 42 10 9 RECEIVE DELAY ...

Page 4: ...0 18 STATE OF THE CREDIT FOR THE PREPAID CARD 44 10 19 STATE OF THE OUTPUTS PORC 44 10 20 MANUAL GSM MODULE RETARD MRES 44 10 21 RECEIVE STATUS OF INPUTS INS 45 10 22 RECEIVE TS NX CL LOG 45 11 CHANGING PARAMETERS USING THE SMS COMMANDS 46 12 DEFAULT SETTINGS ON TS NX CL 48 13 PARAMETERS PRINT OUT COMMANDS 51 14 TECHNICAL SPECIFICATIONS 52 ...

Page 5: ...TS NX CL INSTALLATION MANUAL Page 4 Figures Figure 1 TS NX CL Connection diagram 12 Figure 2 Input Connection diagram 15 Figure 3 Output Connection diagram 20 ...

Page 6: ...parameters 24 Table 11 Credit example 24 Table 12 Set up parameters 29 Table 13 Set up parameters example 30 Table 14 Message parameters 31 Table 15 Message parameters example 32 Table 16 Intercom parameters 34 Table 17 Intercom parameters example 34 Table 18 Entering PIN code parameters 30 Table 19 Entering PIN code example 30 Table 20 CLIP parameters 31 Table 21 CLIP parameters example 334 Table...

Page 7: ...tible to interference which could affect performance SWITCH OFF IN HOSPITALS Follow any restrictions Switch the unit off near medical equipment SWITCH OFF IN AIRCRAFT Follow any restrictions Wireless devices can cause interference in aircraft SWITCH OFF WHEN REFUELING Do not use the unit at a refueling point Do not use near fuel or chemicals SWITCH OFF NEAR BLASTING Follow any restrictions Do not ...

Page 8: ...rcom communication system that is designed to ensure low cost reliable and single box solution for intercom application It is designed for unlimited range wire free GSM intercom and CLIP support In addition TS NX CL supports alarm detection stay alive messages credit detection etc ...

Page 9: ...ll support 2 alarm inputs 2 additional on extension connector 2 outputs relay supported Up to 100 telephone numbers for CLIP support Programming by USB SIM Key editor Download programming by SMS command Anti tampering input Applications Single box wire free intercom solution Remote gate opener CLIP Simple alarm support ...

Page 10: ... you insert the SIM Connect inputs and outputs to TS NX CL Connect the antenna to antenna connector Connect power cable to TS NX CL device Connect device to source power supply voltage Wait until LED3 display is turned ON green and LED1 blue starts flashing This is set in around 1 minute TS NX CL unit is now ready to operate IMPORTANT Before sending any SMS commands to TS NX CL device TS NX CL mus...

Page 11: ...al Red LED LED2 When LED 2 is ON the unit has a problem with a GSM network connection or the GSM part of the unit is out of order In this case immediately call the service Yellow LED LED3 Short flashing indicates that the GSM module is ON but it is not yet connected on the GSM network After connection yellow led is flashing with short pulse ON and a long pulse OFF ...

Page 12: ...a stored in the phone book memory By sending this SMS to TS NX CL all programmed parameters and numbers are cleared SDCLR After sending SMS you should wait at least 60 second for the command to be executed NOTE By sending this command to the TS NX CL all programmed data are erased from the SIM card including SMS messages After the device will start it will be configured with factory defaults ...

Page 13: ...TS NX CL INSTALLATION MANUAL Page 12 7 CONNECTION DIAGRAM Before connection the TS NX CL please take a look at connection diagram Figure 1 TS NX CL Connection diagram ...

Page 14: ...TS NX CL INSTALLATION MANUAL Page 13 ...

Page 15: ...to your personal GSM phone Add programming parameters in SIM Card Phone Book You can program TS NX CL remotely by SMS command You can program TS NX CL with USB key and SIM manager You can program TS NX CL with direct USB connection with the use of configuration software running on PC NOTE To receive configuration software for PC please contact your local distributor ...

Page 16: ...elations needed for alarm to be trigged The second section is used to report alarm 9 1 1 ALARM TRIGGERING Parameters are used to control filter the triggering of the alarm inputs 9 1 1 1 IN parameter Alarm input can be on only used as normal open N O triggered with GND When you need the input feedback information it is possible to receive SMS when input returns from alarm to normal position To rec...

Page 17: ...operation for input 4 ID1 Input time integration delay on input 1 ID2 Input time integration delay on input 2 ID3 Input time integration delay on input 3 ID4 Input time integration delay on input 4 DD1 Time delay for alarm reporting on input 1 DD2 Time delay for alarm reporting on input 2 DD3 Time delay for alarm reporting on input 3 DD4 Time delay for alarm reporting on input 4 Table 1 IN ID and ...

Page 18: ...r reporting alarm events 9 1 2 1 TN parameter Telephone numbers for remote alarm reporting are listed as TN parameters Remote alarm reporting on TS NX CL is done via SMS messages 9 1 2 2 LN parameter This parameter is used to link alarm event from inputs or any other source to the telephone numbers from TN list 9 1 2 3 LOT parameter LOT parameter is used to define the time control for voice calls ...

Page 19: ...7 NAC list No linking TN1 TN5 see note LN8 Log status No linking TN1 TN5 LOT Time out for GSM connection Table 3 Remote alarm reporting parameters NOTE When telephone number calling or messaging TS NX CL is not on the CLIP list not acknowledge event occurs NAC The telephone number responsible for this event can be send to TN user for notification Example Direct programming on the SIM card TS NX CL...

Page 20: ... activate 1 or deactivate 0 the output There is a special case when the user can select for first digit output selection number 0 In this case all outputs control by the same time Combination must be pressed in 2s interval and must be 3s apart to be valid NOTE TS NX CL must be in voice connection to support DTMF output control Example DTMF combination Description 00 Deactivate ALL outputs 01 Activ...

Page 21: ...ehavior OS 0 Disabled OS 1 Bi stable toggle mode OS xxx Mono stable pulse mode duration in seconds Typical connection for the output Figure 3 Output Connection diagram 9 2 2 OD parameter OD parameter is used to link the alarm event directly to output 9 2 3 OP1 OP2 parameters Parameters are used to invert the polarity of the outputs 0 normal 1 inverted ...

Page 22: ...rameters Example Direct programming on the SIM card TS NX CL PROGRAMMING TABLE SIM CARD PHONE BOOK Name Number Description OS1 1 Bistable toggle mode OS2 14 Monostable pulse mode 14s pusle OD1 1 Input 1 activates output 1 OD4 2 Input 2 activates output 2 OP1 1 Output 1 inverted Table 7 Output management parameters example Remote programming by SMS OS1 1 OS2 14 OD1 1 OD4 2 OP1 1 9 3 SECURITY LEVEL ...

Page 23: ...parameter TN1 has access to unit SL 2 Numbers stored under parameters TN1 to TN2 have access to unit SL 3 Numbers stored under parameters TN1 to TN3 have access to unit SL 4 Numbers stored under parameters TN1 to TN4 have access to unit SL 5 Numbers stored under parameters TN1 to TN5 have access to unit Table 8 SL parameter Example Direct programming on the SIM card TS NX CL PROGRAMMING TABLE SIM ...

Page 24: ...edit and time validity checking different parameters are used 9 4 1 1 LCV and SCV parameter LCV is used to set the limit for low credit event If the credit on prepaid SIM cards falls below this limit SMS is send SCV the period of valid operating time varies with different GSM network providers The value can be programmed from 1 to 360 days The default value does not presume any kind of expiry warn...

Page 25: ...e in days CC1 Credit number for credit check universally used CC2 Credit number for credit check dedicated for Italian TIM mobile provider CC3 Credit number for credit check dedicated for Italian Vodafone mobile provider CREF String for parsing replay message from CC1 number CVODA String for parsing replay message from CC2 number CTIM String for parsing replay message from CC3 number Table 10 Prep...

Page 26: ...TS NX CL INSTALLATION MANUAL Page 25 ...

Page 27: ...ameter is used to synchronise TS NX CL clock to GSM network clock User must enter here the number of the TS NX CL SIM card Telephone number of TS NX CL device 9 5 4 RAN parameter Parameter is used to provide support for auto answer options for TS NX CL device The number defines the numbers of rings needed for TS NX CL device to answer the incoming call The incoming number must be on the TN list fo...

Page 28: ...TT 0 this function is disabled 9 5 7 MNF parameter When it is necessary to fix the GSM network to one provider the user can use the MNF parameter The MNF parameter switches automatic network searching to manual Example MCC MNC code for Simobil is 29340 Mobitel is 29341 TIM is 22201 and Vodafone Italy is 22210 More information about national MCC MNC codes can be acquired at http www activexperts co...

Page 29: ... device 9 5 12ADF parameter Parameter is used to define voice refresh function to prevent blocking of SIM in some networks 9 5 13LNG parameter LNG parameter switches between the preprogrammed languages 0 English 1 Italian 2 Slovenian 3 Croatian 4 Dutch 5 German 6 Spanish 9 5 14BUZ parameter Parameter is used to control buzzer functionality on TS NX CL Buzzer is used to audio support some events on...

Page 30: ...rol for automatic system restart ADF Auto dial functionality Call TN1 LNG Language selection BUZ Buzzer control Table 12 Set up parameters Example Direct programming on the SIM card TS NX CL PROGRAMMING TABLE SIM CARD PHONE BOOK Name Number Description HTN 0 Hidden telephone number of the TS NX CL device MNF 29340 Manual fixing of the GSM provider Simobil LNG 1 Switch on Italian language MIC 2 Mic...

Page 31: ...TS NX CL INSTALLATION MANUAL Page 30 Table 13 Set up parameters example Remote programming by SMS HTN 0 MFN 29340 LNG 1 MIC 2 SPK 20 TST 24 BUZ 0 ESC 2 ...

Page 32: ...e message is stored in the SIM phone book so you should add any number for correct operation 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 0 U S E R L O C A T I O N 1 I N P U T 1 2 I N P U T 2 3 I N P U T 3 4 I N P U T 4 NOTE Message should not be longer than 14 characters Space is also counted as one character 9 6 1 Table of parameters Name Comment 0 User location same for all alarm messages 1 Input 1 s...

Page 33: ... supporting up to 8 call buttons The current version is equipped with 1 or 2 call buttons so only E GROUP and F GROUP are used and described in this manual 9 7 1 xTN1 to xTN5 parameters Parameters are the call numbers for intercom application 9 7 2 RTNx parameter Parameter defines the ring time time out RTNx timer is started when the call button is pressed If the RTNx timer expires before the GSM ...

Page 34: ...tionality 24h time format 9 7 4 2 TZEx parameter Parameter is used to configure the end time for the time zone functionality 24h time format 9 7 5 Table of parameters Name Comment ATN1 Button 1 Telephone number 1 ATN2 Button 1 Telephone number 2 ATN3 Button 1 Telephone number 3 ATN4 Button 1 Telephone number 4 ATN5 Button 1 Telephone number 5 RTNA Button 1 time out control for voice connection SDN...

Page 35: ... 1 RTNA 30 Button 1 time out control for voice connection Table 17 Intercom parameters example Remote programming by SMS ATN1 040713470 ATN2 38643364850 BTN1 040123585 RTNA 30 9 8 DIRECT ACCESS BY ENTERING PIN CODE The user may control the predefined outputs by entering the PIN codes PIN code from 1 to 10 PIN1 to PIN10 will activate Output 1 PIN codes from 11 to 20 PIN11 to PIN20 will activate Out...

Page 36: ... PIN code parameters Example Direct programming on the SIM card TS PROGRAMMING TABLE SIM CARD PHONE BOOK Name Number Description PIN1 3369 Pin code 1 PIN12 1234 Pin code 2 Table 19 Entering PIN code example Remote programming by SMS PIN1 3369 PIN12 1234 NOTE PINx codes must be 4 digits long and must start with number greater or equal 1 9 9 CLIP CLIP is used to provide the free of charge options to...

Page 37: ...4 CLP1 CLP100 parameter Set of telephone number which can control the output The number not on CLP list is not able to control the output using clip functionality 9 9 5 Table of parameters Name Comment CLPEN Enable CLIP functionality CLPOU Control output pin when CLIP event CLPI CLIP input activation condition CLP1 CLIP number 1 CLP100 CLIP number 100 Table 20 CLIP parameters Example Direct progra...

Page 38: ...ption CLPEN 1 Enable CLIP functionality CLPOU 2 CLIP control output 2 CLPI 0 No input activation condition CLP1 040414414 CLIP number 1 CLP2 042340880 CLIP number 2 Table 21 CLIP parameters example Remote programming by SMS CLPEN 1 CLPOU 2 CLPI 0 CLP1 040414414 CLP2 042340880 ...

Page 39: ...S NX CL User can select between nonvolatile memory on TS NX CL or select USB to transfer events directly via USB to PC LOGI 0 Logging is OFF LOGI 1 Logging in internal memory LOGI 2 Logging to USB interface 9 10 3ALC parameter Parameter is used to control behavior when log on TS NX CL is full User can select between auto log clear or manual clear of log ALC 0 Automatically delete buffer when memor...

Page 40: ...s auto cleared when full Table 19 LOG parameters example Remote programming by SMS LOGN 5 LOGI 0 ALC 1 9 11 SPECIAL SMS COMMANDS These commands can only be issued only over SMS message and are used to control some special functions of TS NX CL device 9 11 1ORC command Command is used to control outputs directly via SMS message 9 11 2SDCLR command To clear all data on SIM card SDCLR command is used...

Page 41: ...e Comment ORC1 Control of output 1 ORC2 Control of output 2 SDCLR Delete all SIM content LCRL Delete log on TS NX CL device MRES Manual reset of GSM module SSRES Manual reset of TS NX CL device Table 20 SMS commands Example Remote programming by SMS SMS commad Description ORC1 1 Activate output 1 ORC2 0 Deactivate output 2 SDCLR Clear all data on SIM LCLR Delete log on TS NX CL device MRES Manual ...

Page 42: ...command to TS NX CL you receive SMS messages with current SW version running on TS NX CL device PSW 10 3 CHECK SIGNAL QUALITY PSQ By sending this command to TS NX CL you receive SMS messages with signal quality TS NX CL device is connected to network PSQ 10 4 RECEIVE TELEPHONE NUMBERS PTN By sending this command to TS NX CL you receive SMS message with all currently programmed telephone numbers TN...

Page 43: ...UE POD By sending this command to TS NX CL you receive SMS message with all currently programmed direct output links OD1 OD5 POD 10 9 RECEIVE DELAY BEFORE DIAL VALUE PDD By sending this command to TS NX CL you receive SMS message with all currently programmed Input filters DD1 DD4 PDD 10 10 RECEIVE ACCESS TELEPHONE NUMBERS PSL By sending this command to TS NX CL you receive SMS message with progra...

Page 44: ...ameters TST MNF PPA 10 14 RECEIVE CREDIT PARS PARAMETERS PCREF By sending this command to TS NX CL you receive SMS message with all currently programmed credit parse parameters CREF CVODA PCREF 10 15 RECEIVE ALL CLIP PARAMETERS PCLP By sending this command to TS NX CL you receive SMS message with all currently programmed CLIP functionality related parameters CLPEN CLPOU CLPI CLPx PCLP NOTE User ca...

Page 45: ...ers BTN1 BTN2 BTN3 BTN4 BTN5 RTNB SDNB SDDB TZSB TZEB PDEB 10 18 STATE OF THE CREDIT FOR THE PREPAID CARD By sending this command to TS NX CL you receive SMS message with Credit amount on your prepaid SIM card PCCX Where X is the number of programmed prepaid card provider 10 19 STATE OF THE OUTPUTS PORC By sending this command to TS NX CL you receive SMS message with current outputs state PORC 10 ...

Page 46: ...u receive SMS message with current input state INS 10 22 RECEIVE TS NX CL LOG By sending this command to TS NX CL you receive SMS message with log on TS NX CL device PLOG NOTE User can use PLOG x y to define the number of logs to be printed x start event y end event Example PLOG 1 30 Prints first 30 log events ...

Page 47: ...ike to enter telephone numbers in to TS NX CL you can use the following example TN1 040713470 TN2 38643364850 If you would like to receive confirmation SMS write before SMS command TN1 040713470 TN2 38643364850 Return SMS from TS NX CL is TN1 040713470 TN2 38643364850 NOTE You can use the same programming procedure for all parameters It is also possible to change different parameters with one SMS ...

Page 48: ...TALLATION MANUAL Page 47 Send SMS message to TS NX CL telephone number and in a few seconds you receive SMS message from TS NX CL The sentence of the SMS must be the same as the one you have sent to TS NX CL before ...

Page 49: ...y Input 1 link to tel numbers LN2 1 Input 2 link to tel numbers LN3 Empty Input 3 link to tel numbers LN4 1 Input 4 link to tel numbers LN5 Empty Periodic SMS text link to tel numbers LN6 Empty SIM card refill link to tel numbers LN7 Empty NAC link to tel numbers LN8 Empty LOG full link to tel numbers ID1 1 Input 1 delay filter on input ID2 120 Input 2 delay filter on input ID3 1 Input 3 delay fil...

Page 50: ...events for printing out LOGI 0 Log interface ALC 1 Automatic log clear ADF 90 Auto dial functionality Call TN1 ARST 0 Automatic reset timeout CREF EUR Parse text contact support CTIM EURO Parse text contact support CVODA DISPON E Parse text contact support OP1 1 Output invert 1 OP2 1 Output invert 2 BUZ 1 Buzzer control SPO 1 SIM card starting position CLPEN 1 Enable CLIP functionality CLPOU 1 Con...

Page 51: ...elephone number 1 BTN2 Empty Button 2 Telephone number 2 BTN3 Empty Button 2 Telephone number 3 BTN4 Empty Button 2 Telephone number 4 BTN5 Empty Button 2 Telephone number 5 RTNB 25 Ring time Button 2 SDNB 0 DTMF number to send SDDB 0 Delay for DTMF to send TZSB 0 Time zone start interval TZEB 0 Time zone end interval Table 22 TS NX CL default settings ...

Page 52: ...Prints SL parameter POS Prints OSx parameters P Prints x parameters PPA Prints various setup parameters PCLP Prints CLIP parameters PLOG Prints log of the TS NX CL PCREF Prints credit pars parameters PCN Prints credit request numbers PCC1 Prints credit for TS NX CL universal request PCC2 Prints credit for TS NX CL TIM Italy PCC3 Prints credit for TS NX CL VODAFONE Italy PWG Prints Wiegand paramete...

Page 53: ...ransmitting mode 250mA Current consumption idle mode 80mA Quad band GSM module 850 900 1800 1900 MHz PCB dimensions 106 89 mm Unit dimensions 290 116 56 mm Call buttons 1 or 2 External Antenna SMA 1 Weight 1500 gr Alarm inputs 2 Alarm outputs relay 2 12V DC Aux Power Supply output Y max 100 mA 12 24V AC DC Power Supply input Y Anti tamper protection optional ...

Page 54: ...HE GOODS EXPRESS OR IMPLIED INCLUDING WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE BUYER MAKES NO RELIANCE ON ANY REPRESENTATION OF TRANSMITTER SOLUTIONS EXPRESS OR IMPLIED WITH REGARD TO THE GOODS AND ACCEPTS THEM AS IS WHERE IS TRANSMITTER SOLUTIONS SELLS THE GOODS TO BUYER ON CONDITION THAT TRANSMITTER SOLUTIONS WILL HAVE NO LIABILITY OF ANY KIND AS A RESULT OF TH...

Reviews: