TS-‐NX/CL
INSTALLATION MANUAL
Page 18
TN1
1
st
telephone number
TN2
2
nd
telephone number
TN3
3
rd
telephone number
TN4
4
th
telephone number
TN5
5
th
telephone number
LN1
Input & telephone No. linking for 1
st
alarm input (TN1 –
TN5)
LN2
Input & telephone No. linking for 2
nd
alarm input (TN1
– TN5)
LN3
Input & telephone No. linking for 3
nd
alarm input (TN1
– TN5)
LN4
Input & telephone No. linking for 3
nd
alarm input (TN1
– TN5)
LN5
Periodic test SMS. No. linking (TN1 – TN5)
LN6
SIM card refill. No. linking (TN1 – TN5)
LN7
NAC list. No. linking (TN1 – TN5) (see note)
LN8
Log status. No. linking (TN1 – TN5)
LOT
Time out for GSM connection.
Table 3: Remote alarm reporting parameters
NOTE
When telephone number (calling or messaging TS-NX/CL) is not on the
CLIP list, not acknowledge event occurs (NAC). The telephone number
responsible for this event can be send to TN user for notification.
Example:
♦
Direct programming on the SIM card
TS-NX/CL PROGRAMMING TABLE
SIM CARD PHONE BOOK
Name
Number
Description
TN1
042376678 1st telephone number
LN1
13
Input 1 reports alarm to TN1 & TN3
LN2
1234
Input 2 reports alarm to TN1 & TN2 & TN3 &
TN4
LN7
1
NAC event sent to TN1
LOT
60
Voice connection stay valid for max of 60s,
after this time