To change the master code 

 0  New code  #  New code # 

The master code can be 6 to 8 digits long 

Setting the working mode: 

Set valid card only users 

Set valid card 

and

 PIN users 

Set valid card 

or

 PIN users 

       

 3   0   #

   

Entry is by card only

 

 3   1   #

   

Entry is by card 

and

 PIN together

 

 3   2   #

   

Entry is by either card 

or

 PIN (default)

 

To add a user in either card or PIN mode, i.e. in the 3   2   #  mode. (Default setting) 

To add a 

Pin

 user 

1  User ID number  #  PIN #  

The ID number is any number between 1 & 1500. The 

PIN is any four digits between 0000 & 9999 with the 

exception of 1234 which is reserved. Users can be added 

continuously without exiting programming mode as 

follows: 

1    User ID no 1 #    PIN # User ID no 2 #    PIN # 

To delete a 

PIN

 user 

2  User ID number  #   

Users can be deleted continuously without exiting 

programming mode 

To change the 

PIN

 of a PIN user   

(This step must be done out of 

programming mode) 

 *  ID number #  Old PIN #  New PIN #  New PIN # 

To add a 

card

 user (Method 1) 

This is an easy way to enter the individual 

cards using ID number auto generation. 

1  Read Card  # 

Cards can be added continuously without exiting 

programming mode 

To add a 

card

 user (Method 2) 

This is the alternative way to enter the 

individual card using User ID Allocation. 

In this method a User ID is allocated to a 

card. Only one user ID can be allocated 

to a single card. 

1  ID number  # Card  #   

 

To add a 

series cards

 users – 

Block 

Enrollment 

 

5  ID number  #  8 digits Card number  # Card 

quantity  #  

Card quantity is between 1-1500. Of the 8 digits card 

number, for HID card, they are the 3 digits of a facility 

code and 5 digits of a serial number; for EM card, they 

are the last 8 digits on the card.   

Summary of Contents for BC-2010

Page 1: ...Model BC 2010 HID EM Keypad Reader Controller User Manual...

Page 2: ...be logged in To change the master code 0 New code New code The master code can be 6 to 8 digits long To add a PIN user 1 User ID number PIN The ID number is any number between 1 1500 The PIN is any f...

Page 3: ...ehouses laboratories banks and prisons 4 Features z Strong Zinc Alloy Electroplated anti vandal case z Full programming from the keypad z 1500 uses supports Card PIN Card PIN z Can be used as a stand...

Page 4: ...d Interface Wiegand 26 bit Wiring Connections Electric Lock Exit Button DOTL External Alarm Dimensions L128 x W82 x H28 mm Net Weight 500 g Gross Weight 700 g 6 Installation z Remove the back cover fr...

Page 5: ...Input Black GND 0V DC Regulated Power Input Blue NO Relay output NO Purple COM Relay output COM Orange NC Relay output NC Connection Diagram Notes BC 2010 uses a standard 10 pin connector J1 The diag...

Page 6: ...mper alarm will operate 10 Sound and Light indication Operation Status Red Light Green Light Yellow Light Buzzer Power on Bright Short Ring Stand by Bright Press keypad Short Ring Operation successful...

Page 7: ...ID number Users can be deleted continuously without exiting programming mode To change the PIN of a PIN user This step must be done out of programming mode ID number Old PIN New PIN New PIN To add a...

Page 8: ...rd a PIN as follows Read card 1234 PIN PIN To change a PIN in card and PIN mode Method 1 Note that this is done outside programming mode so the user can undertake this themselves Read Card Old PIN New...

Page 9: ...t closed properly the inside buzzer and alarm output will both operate The Alarm Output time is adjustable between 0 3 minutes with the default being 1 minute To disable door open detection Factory de...

Page 10: ...BC 2010 operating as a Controller In this mode the BC 2010 supports a Wiegand 26 bit input so an external Wiegand device with a 26 bit output can be connected to the Wiegand input terminals on the BC...

Page 11: ...r one for entry and the other for exit Either device acts as the controller and reader at the same time Users can be enrolled on either of the devices In this mode the user capacity for one door can b...

Page 12: ...received including interference that may cause undesired operation NOTE 1 Any changes or modifications not expressly approved by the manufacturer could void the user s authority to operate the equipm...

Reviews: