background image

StackMaster™ TX12

12

3

100BASE-TX 12-Port Stackable Hub

5. MAINTENANCE

WARNING: DO NOT, UNDER ANY CIRCUMSTANCES,
open and attempt to repair the StackMaster TX12 100BASE-
TX 12-Port Stackable Hub.  Failure to observe this warning
could result in personal injury or death from electrical
shock.

NOTE: Failure to observe the above warning will immediately void
the warranty.

Fault Isolation

If two network devices fail to communicate through the
StackMaster TX12, consider the following:

Are the LEDs described in the previous section functioning
properly?

Do network devices have Link Integrity enabled?

Do network devices communicate when the StackMaster
TX12 is not installed between them? 

Is flat or “silver satin” wire used in site internal wiring?

Are internal wiring patch cords, punch down blocks, and
wall jacks properly pinned or configured?

Are network interface cards properly configured?

Technical Support Contact

For assistance in fault isolation and in maintaining the StackMaster
TX12 100BASE-TX 12-Port Stackable Hub, contact: 

Technical Support

(800) 260-1312

or your local distributor.

StackMaster TX12 Connectors and Status 
Indicators

RJ-45 Connectors

Twelve (12) 100BASE-TX RJ-45 connectors are located at the front of
the StackMaster TX12. The RJ-45  jacks support connection to
Category 5 shielded or unshielded 100 ohm twisted pair 100BASE-TX
cable. 

SCSI Connectors

Two (2) SCSI connectors are located at the back of the StackMaster
TX12 for optionally cascading hubs. 

Power Connector

An external power connector is located at the back of the StackMaster
TX12. 

Status LEDs

Status LEDs are located at the front of the StackMaster TX12.

P

OWER

Illuminated green:  Hub powered ON.

U

TILIZATION

Iilluminated green 1%, 8%, 16%, 32%, or 64%
network activity

C

OLLISION

Illuminated amber: Collision detected during data
transmission on ANY port.

L

INK

/A

CTIVITY

Illuminated green: Port link established.
Flashing green: Data being received.

E

RROR

Flashing yellow: Error detected on port.
Illuminated yellow: Port partitioned and isolated.

Summary of Contents for SMHB-E-TX-12

Page 1: ...Class 1 stacked Class 2 unstacked Physical Dimensions 17 x 10 x 1 8 438 mm x 255 mm x 45 mm Shipping Weight 9 lbs 4 1 kg Input Power Internal universal input 100 240VAC 50 60 Hz 53W AC Input Cord TN...

Page 2: ...permission from TRANSITION Networks Trademark Notice All registered trademarks and trademarks are the property of their respective owners Der Anschluss dieses Ger tes an ein ffentlickes Telekommunika...

Page 3: ...e limited collision domain in 100BASE X use the shortest cables possible to make a connection between any two devices Where collisions are not a consideration full duplex longer cable may be possible...

Page 4: ...ct tort or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to a customer or any third par...

Page 5: ...ERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS FOR A PARTICULAR...

Page 6: ...Contact For assistance in fault isolation and in maintaining the StackMaster TX12 100BASE TX 12 Port Stackable Hub contact Technical Support 800 260 1312 or your local distributor StackMaster TX12 Con...

Page 7: ...ed ERROR Flashing yellow Error detected on port OR port partitioned and isolated 2 SITE CONSIDERATIONS The site for the StackMaster TX12 hub must provide AC power outlet for each hub Adequate ventilat...

Page 8: ...ter TX12 Link Integrity cannot be disabled All devices connected to the StackMaster TX12 MUST have link functions enabled To install the StackMaster TX12 Unpack the StackMaster TX12 Hub Install StackM...

Page 9: ...TX12 between the 19 inch rack mounting rails at the installation position 3 Install two screws through right front bracket and two screws through left front bracket using clip nuts if necessary Connec...

Page 10: ...aster TX12 hub as shown above 5 Continue connecting SCSI cables by repeating steps 3 and 4 until the entire StackMaster TX12 stack is cascaded NOTE The open SCSI connectors at the top and bottom of th...

Reviews: