100BASE-TX 12-Port Stackable Hub

4. OPERATION

The StackMaster TX12 normally requires no intervention beyond
occasionally monitoring  the Power and Status LEDs.

Status LEDs

Status LEDs are located at the front of the StackMaster TX12.

P

OWER

Illuminated green:  Hub powered ON.

U

TILIZATION

Iilluminated green 1%, 8%, 16%, 32%, or 64%
network activity

C

OLLISION

Illuminated amber: Collision detected during
data transmission on ANY port.

L

INK

/A

CTIVITY

Illuminated green: Port link established.
Flashing green: Data being received.

E

RROR

Flashing yellow: Error detected on port. OR
port partitioned and isolated.

2. SITE CONSIDERATIONS

The site for the StackMaster TX12 hub must provide:

AC power outlet for each hub

Adequate ventilation

Standard environmental conditions

Isolation from electrical noise, including radio transmitters
and broadband amplifiers, motors, high power electrical
lines, or fluorescent light fixtures.

Additionally: 

The twisted pair cables should not run in the same conduit
with power line cables

Phone lines should be separated from data cables

Flat or “silver satin” wires should not be used.

And: 

Since the StackMaster TX12 functions as an Ethernet
Repeater, the entire installation should comply with the IEEE
Ethernet 802.3 specification.

Summary of Contents for SMHB-E-TX-12

Page 1: ...Class 1 stacked Class 2 unstacked Physical Dimensions 17 x 10 x 1 8 438 mm x 255 mm x 45 mm Shipping Weight 9 lbs 4 1 kg Input Power Internal universal input 100 240VAC 50 60 Hz 53W AC Input Cord TN...

Page 2: ...permission from TRANSITION Networks Trademark Notice All registered trademarks and trademarks are the property of their respective owners Der Anschluss dieses Ger tes an ein ffentlickes Telekommunika...

Page 3: ...e limited collision domain in 100BASE X use the shortest cables possible to make a connection between any two devices Where collisions are not a consideration full duplex longer cable may be possible...

Page 4: ...ct tort or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to a customer or any third par...

Page 5: ...ERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS FOR A PARTICULAR...

Page 6: ...Contact For assistance in fault isolation and in maintaining the StackMaster TX12 100BASE TX 12 Port Stackable Hub contact Technical Support 800 260 1312 or your local distributor StackMaster TX12 Con...

Page 7: ...ed ERROR Flashing yellow Error detected on port OR port partitioned and isolated 2 SITE CONSIDERATIONS The site for the StackMaster TX12 hub must provide AC power outlet for each hub Adequate ventilat...

Page 8: ...ter TX12 Link Integrity cannot be disabled All devices connected to the StackMaster TX12 MUST have link functions enabled To install the StackMaster TX12 Unpack the StackMaster TX12 Hub Install StackM...

Page 9: ...TX12 between the 19 inch rack mounting rails at the installation position 3 Install two screws through right front bracket and two screws through left front bracket using clip nuts if necessary Connec...

Page 10: ...aster TX12 hub as shown above 5 Continue connecting SCSI cables by repeating steps 3 and 4 until the entire StackMaster TX12 stack is cascaded NOTE The open SCSI connectors at the top and bottom of th...

Reviews: