6.8 System Event Log
This page allows the user to decide whether to send the system event log, and select the
mode which the system event log will be sent to client only, server only, or both client
and server. What kind of event log will be issued to the client/server depends on the
selection on the
Event Configuration
tab. There are five types of event—Device Cold
Start, Device Warm Start, Authentication Failure, X-Ring Topology Change, and Port
Event—available to be issued as the event log.
6.8.1 Syslog Configuration
Syslog Client Mode:
Select the system log mode—
Client Only
,
Server Only
, or
Both
. ‘Client Only’ means the system event log will only be sent to this interface of the
switch, but on the other hand ‘Server Only’ means the system log will only be sent to
the remote system log server with its IP assigned. If the mode is set in ‘Both’, the
system event log will be sent to the remote server and this interface.
System Log Server IP Address:
When the ‘Syslog Mode’ item is set as Server
Only/Both, the user has to assign the system log server IP address to which the log
will be sent.
Click
Reload
to refresh the event log displaying area.
Click
Clear
to clear all the current event logs.
Make sure the selected mode is correct, and click
Apply
to have the setting take
effect.