background image

2

SGETF10xx-1xx

24-hour Technical Support: 1-800-260-1312   International: 00-1-952-941-7600    

Part Number

Port One - Copper Port Two - Single Fiber-Optic

SGETF1029-110

RJ-45 1000Base-T
100 m 

(328 ft)*

SC, 1000Base-LX, 1310 TX/1550 RX 
single mode, 20 km 

(12.4 miles)*

SGETF1029-111

RJ-45 1000Base-T
100 m 

(328 ft)

*

SC, 1000Base-LX, 1550 TX/1310 RX 
single mode, 20 km 

(12.4 miles)*

SGETF1029-112

RJ-45 1000Base-T
100 m 

(328 ft)*

SC, 1000Base-LX, 1310 TX/1550 RX 
single mode, 40 km 

(24.8 miles)*

SGETF1029-113

RJ-45 1000Base-T
100 m 

(328 ft)*

SC, 1000Base-LX, 1550 TX/1310 RX 
single mode, 40 km 

(24.8 miles)*

SGETF1029-116

RJ-45 1000Base-T
100 m 

(328 ft)*

SC, 1000Base-LX, 1510 TX/1590 RX 
single mode, 80 km 

(49.7 miles)*

SGETF1029-117

RJ-45 1000Base-T
100 m 

(328 ft)*

SC, 1000Base-LX, 1590 TX/1510 RX 
single mode, 80 km 

(49.7 miles)*

The SGETF1029-11x and the SGETF1029-11x are to be installed in
the same network, where one is the local converter and the other
is the remote converter.

* Typical maximum cable distance. Actual distance is dependent upon the physical

characteristics of the network installation 

(TX = transmit, RX = receive).

*Typical maximum cable distance. Actual distance is dependent upon the physical
characteristics of the network.

Note:

Third-party Multi-Source Agreement (MSA) compliant Small Form Factor

Pluggables (SFPs) can also be used in the SGETF1040-110.

Sold separately, the following SFP transceiver modules for port two are compatible
with the SGETF1040-110 converter and are available from Transition Networks. 

SGETF1040-110 Descriptions

TN-SFP-SX

LC, 1000Base-SX, 850 nm multimode, 220-550 mm 

(720-1804 ft)

*

TN-SFP-SXD

LC, 1000Base-SX, 850 nm multimode, 220-550 mm 

(720-1804 ft)

*

TN-SFP-LX1

LC, 1000Base-LX, 1310 nm single mode, 10 km 

(6.2 miles)

*

TN-SFP-LX3

LC, 1000Base-LX, 1310 nm single mode, 30 km 

(18.8 miles)

*

TN-SFP-LX5

LC, 1000Base-LX, 1550 nm single mode, 50 km 

(31.2 miles)

*

TN-SFP-LX8

LC, 1000Base-LX, 1550 nm single mode, 80 km 

(50.0 miles)

*

TN-SFP-LX12

LC, 1000Base-LX, 1550 nm single mode, 120 km 

(74.6miles)

*

Part Number

Port One - Copper Port Two - Single Fiber-Optic

SGETF1040-110

RJ-45 1000Base-T
100 m 

(328 ft)*

Open slot for SFP modules

[email protected] -- Click the “Transition Now” link for a live Web chat.

3

Installation 

Set the 6-position switch

The 6-position switch is located on

the side of the media
converter.  

Use a small flat blade
screwdriver to set the
recessed switches.  

All switches are shown in the
default position, UP.  

Note:

Switch positions S2 and S3 work together to configure the media converter
for Pause conditions. 

S1

Remote-Fault Detection
up

Disabled

down

Enable 

S2 & S3 work in combination 

Pause
10 sw position 2 up and 3 down: 

Symmetric

01 sw position 2 down and 3 up: 

Asymmetric

11 sw positions 2 and 3 up:  Pause is OFF 

(default position)

00 sw positions 2

and 3 down: 

Symmetric and Asymmetric

S4

Transparent Link Pass-Through
up

Enable Link Pass-Through

down

Disable Link Pass-Through

S5

Fiber Auto-Negotiation
up

Disable Fiber Auto-Negotiation for the fiber link 
(

default setting)

down

Enable Fiber Auto-Negotiation for the fiber link

S6

Loop Back
up

Disable RX/TX signal loop back 

(default setting)

down

Enable RX/TX signal loop back 

2. Pause (symmetric) 

3. Pause (asymmetric) 

4. Transparent Link Pass-Through

5. Auto-Negotiation

1. Remote Fiber Fault Detect 

6. Loop Back

Summary of Contents for SGETF1013-110

Page 1: ...ation 3 Operation 7 Cable Specifications 9 Technical Specifications 11 Troubleshooting 12 Contact Us 13 Compliance Information 15 Part Number Port One Copper Port Two Duplex Fiber Optic SGETF1013 110...

Page 2: ...00Base SX 850 nm multimode 220 550 mm 720 1804 ft TN SFP SXD LC 1000Base SX 850 nm multimode 220 550 mm 720 1804 ft TN SFP LX1 LC 1000Base LX 1310 nm single mode 10 km 6 2 miles TN SFP LX3 LC 1000Base...

Page 3: ...Once the twisted pair interface has a link at the highest common capability it passes the result to the fiber interface 4 The fiber interfaces then start advertising these capabilities At this point...

Page 4: ...n the network PWR Power ON Connected to external AC power LKF Fiber link ON Fiber Connection RXC Copper receive Flashing Receiving data on the copper link ON Copper Link connection Duplex ON Full Remo...

Page 5: ...egment This type of diagnostic test can only be performed from the local to the remote device with loop back enabled on the remote device SNMP Note SNMP is not supported in the SGETF10xx 1xx converter...

Page 6: ...HDBK 217F 1 345 000 hours Bellcore7 V5 0 Operating Temp Tmra 0 C to 50 C 32 F to 122 F Storage Temp 15 C to 65 C 5 F to 149 F Humidity 10 to 90 non condensing Altitude 0 to 10 000 feet Warranty Lifet...

Page 7: ...is disabled DIP switch 5 in the UP position Contact Tech Support 1 800 260 1312 Int l 00 1 952 941 7600 YES Proceed to step 4 4 Is the RXC copper receive LED flashing NO If there is activity on the 10...

Page 8: ...l apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent appareil num...

Page 9: ...the property of their respective owners Copyright restrictions 2003 2005 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic ele...

Reviews: