Transition Networks S4TEF10xx-10x User Manual Download Page 7

14

S4TEF10xx-10x

7

24-Hour Technical Support: 1-800-260-1312  International: 00-1-952-941-7600 

[email protected] -- Click the “Transition Now” link for a live Web chat.

Installation — Continued

Hardware/Software Jumper

The 3-pin header (J11) is inside is located near the back end of the upper circuit
board. 

Hardware

The Device mode is determined by the switch
settings .

Software

The Device mode is determined by the most-
recently saved, on-board microprocessor
settings.

H

J11

S

H

S

J11

1

2

3

1

2

3

Pins

Hardware Mode

Software Mode

To set the jumper:

1.

Using a small screwdriver, remove the
four (4) screws that secure the cover
and carefully remove the cover from
the Device.

2.

Locate the 3-pin header (J11).

3.

Using small needle nose pliers or
similar device, move the jumper to the
desired position (

see above).

4.

Carefully replace the cover on the
Device and replace the four (4) screws
that secure the cover to the Device.

Power the Device 

1.

Connect the barrel connector on the power adapter to the Device’s power port

(located on the back of the Device)

2.

Connect the power adapter plug to AC power.

3.

Verify that the Device is powered by observing the illuminated LED power
indicator light.

Note:

For DC power, consult the user’s guide for the Transition Networks
SPS1872-xx DC external power supply.

Cable Specifications — Continued                                                                                                    

RS-232 Cable 

(included)

Connectors:

6-pin DIN and DB-9

Gauge:

24 to 22 AWG

Attenuation: 

20 dB/1000 ft. @ 10 MHz

Differential characteristic impedance:

100 ohm +/- 10% @ 10 MHz

Maximum cable distance:

<10 ft 

(3.2 m)

@ 56 kb/s or higher

1

2

3

4

5

6

7

8

9

3

2

1

4

6

5

 Signal Ground  3 & 5

 Transmit Signal  1

Receive signal  2

Clear to send  9

2   Receive Data

7   Request Data

3   Transmit Data

5   Signal Ground

DIN 6-Pin

DB-9

Summary of Contents for S4TEF10xx-10x

Page 1: ...r Interference by Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference in commercial and or industrial areas When used in a residential area or in an adjacen...

Page 2: ...cal Support Technical support is available 24 hours a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Transition Now Chat live via the Web with Transition Networks Technical Support L...

Page 3: ...m DSX 1 100 ohm 133 266 ft 40 5 81 m 1 2 DS1 100 ohm 0 dB LBO DS1 100 ohm 7 5 dB LBO DSX 1 100 ohm 533 655 ft 162 200 m J1 110 ohm 0 655 ft 0 200 m 3 E1 120 ohm DS1 100 ohm 15 dB LBO DS1 100 ohm 22 5...

Page 4: ...nagement mode See the SNMP section for the commands that are supported via the RS 232 connector up down Enable Disable 9 up down Data port mode Local management mode 10 Troubleshooting Continued 5 Is...

Page 5: ...by determining the answers to the following questions and then taking the indicated action 1 Is the PWR LED illuminated NO Ensure that the power adapter is the proper type of voltage and cycle frequen...

Page 6: ...d temp models 105 106 07 108 Storage Temperature 40 to 85 C 40 to 185 F Humidity 5 to 95 non condensing Warranty Lifetime The information contained in this user s guide is subject to change For the mo...

Page 7: ...e the jumper to the desired position see above 4 Carefully replace the cover on the Device and replace the four 4 screws that secure the cover to the Device Power the Device 1 Connect the barrel conne...

Page 8: ...he cable to the RS 232 port on a computer or other device that is used to collect and display data Cable Specifications Continued T1 E1 Cable Category 3 minimum requirement Connector RJ 48C Electrical...

Page 9: ...ensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dB S4TEF1013 100 105 1300 nm multimode Fiber Optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivity min 30 0 dBm max 1...

Page 10: ...chassis The SNMP section below lists the commands that can be used to monitor and manage a networked S4TEF10xx 10x Device at a remote location For more details see the C4TEF10xx 10x user s guide on li...

Reviews: