Transition Networks S4TEF10xx-10x User Manual Download Page 3

18

S4TEF10xx-10x

3

24-Hour Technical Support: 1-800-260-1312  International: 00-1-952-941-7600 

[email protected] -- Click the “Transition Now” link for a live Web chat.

Installation — Continued

Configuration Switches

The S4TEF10xx-10x Device has two (2) sets of configuration switches.  

Set #1  sets the T1/E1 options.

Set #2 sets the serial options.

Use a flat blade screwdriver to set the switches as shown:

Switch Set #1 - T1/E1 Options

1, 2, 3, 4 - Line Settings 

Switches 1, 2, 3, and 4 are used to setup the line settings for the T1/E1 ports.  The
selected setting applies to all four (4) T1/E1 channels.

Side View

10-Switch Set 1 (upper)  T1/E1 options

10-Switch Set 2 (lower) Serial Options

Key:

up

down

DSX-1, 100 ohm, 266-399 ft. (81-122 m)

DSX-1, 100 ohm, 399-533 ft. (122-162 m)

DSX-1, 100 ohm, 0-133 ft. (0-40.5 m)

DSX-1, 100 ohm, 133-266 ft. (40.5-81 m)

1 2

DS1, 100 ohm, 0 dB LBO

DS1, 100 ohm, -7.5 dB LBO

DSX-1, 100 ohm, 533-655 ft. (162-200 m)

J1, 110 ohm, 0-655 ft. (0-200 m)

3

E1, 120 ohm

DS1, 100 ohm, -15 dB LBO

DS1, 100 ohm, -22.5 dB LBO

4

1 2 3 4

Troubleshooting — Continued

6.

Is data transfer failing on the fiber port?
YES

• Verify the local fiber connection by starting a remote fiber loop-back:

- HW mode: set the remote Device to fiber loop-back.
- SW mode: enter the remote fiber loop-back command. 

• Use a bit error test unit to run a bit error test.

• Verify the remote fiber connection by starting a local fiber loop-back:

- HW mode: set the local Device to fiber loop-back.
- SW mode: enter the remote fiber loop-back command.

• Use a bit error test unit to run a bit error test.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

NO

• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

r

e

p

p

o

C

r

e

b

i

F

r

e

p

p

o

C

Remote

Device

Local

Device

r

e

p

p

o

C

r

e

b

i

F

r

e

p

p

o

C

Remote

Device

Local

Device

Summary of Contents for S4TEF10xx-10x

Page 1: ...r Interference by Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference in commercial and or industrial areas When used in a residential area or in an adjacen...

Page 2: ...cal Support Technical support is available 24 hours a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Transition Now Chat live via the Web with Transition Networks Technical Support L...

Page 3: ...m DSX 1 100 ohm 133 266 ft 40 5 81 m 1 2 DS1 100 ohm 0 dB LBO DS1 100 ohm 7 5 dB LBO DSX 1 100 ohm 533 655 ft 162 200 m J1 110 ohm 0 655 ft 0 200 m 3 E1 120 ohm DS1 100 ohm 15 dB LBO DS1 100 ohm 22 5...

Page 4: ...nagement mode See the SNMP section for the commands that are supported via the RS 232 connector up down Enable Disable 9 up down Data port mode Local management mode 10 Troubleshooting Continued 5 Is...

Page 5: ...by determining the answers to the following questions and then taking the indicated action 1 Is the PWR LED illuminated NO Ensure that the power adapter is the proper type of voltage and cycle frequen...

Page 6: ...d temp models 105 106 07 108 Storage Temperature 40 to 85 C 40 to 185 F Humidity 5 to 95 non condensing Warranty Lifetime The information contained in this user s guide is subject to change For the mo...

Page 7: ...e the jumper to the desired position see above 4 Carefully replace the cover on the Device and replace the four 4 screws that secure the cover to the Device Power the Device 1 Connect the barrel conne...

Page 8: ...he cable to the RS 232 port on a computer or other device that is used to collect and display data Cable Specifications Continued T1 E1 Cable Category 3 minimum requirement Connector RJ 48C Electrical...

Page 9: ...ensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dB S4TEF1013 100 105 1300 nm multimode Fiber Optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivity min 30 0 dBm max 1...

Page 10: ...chassis The SNMP section below lists the commands that can be used to monitor and manage a networked S4TEF10xx 10x Device at a remote location For more details see the C4TEF10xx 10x user s guide on li...

Reviews: