Installation — Continued

Switch Set #2 - Serial Options

1, 2, 3 - Serial Connection Speed Line Settings 

Switches 1, 2, and 3 on switch set #2 are used to set the serial connection speed.  

4800 baud

9600 baud

1200 baud

2400 baud

1 2 3

57600 baud

115200 baud

19200 baud

38400 baud

1 2 3

4.  Enable/Disable Parity

When parity is enabled, an additional bit is added to the
8-bit signal to identify whether the signal is sent
successfully. Use switch 5 to send odd or even signal
parity.

Up - Disable parity.

Down - Enable parity. 

5.  Parity Select

Up - Select odd serial parity.

Down - Select even serial parity.

This switch is inactive if switch 4 is (up).

Disable Parity

Enable Parity

down

up

4

Odd Serial Parity

Even Serial Parity

up

5

down

Troubleshooting

If the Device fails, isolate and correct the failure by determining the answers to the
following questions and then taking the indicated action:

1.

Is the “PWR” LED illuminated?
NO

• Ensure that the power adapter is the proper type of voltage and cycle

frequency for the outlet. 

• Ensure the power adapter is properly installed in the Device and in the

grounded outlet.

• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

YES

• Proceed to step 2.

2.

Is the “LKF” LED illuminated?
NO

• Check the fiber cables for proper connection.
• Verify that the TX and RX cables on the local Device are  connected to the

RX and TX ports, respectively, on the remote Device.

• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

YES

• Proceed to step 3.

3.

Is the “LNK” LED on a T1/E1port

(with a copper cable installed)

illuminated?
NO

• Check the copper cable connected to that T1/E1 port for proper connection. 
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

YES

• Proceed to step 4.

4.

Is the “AIS” LED on a T1/E1 port 

(with a copper cable installed)

illuminated?
YES

• The device connected to the T1/E1 port has failed. Correct the device

failure. 

• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.

NO

• Proceed to step 5.

Summary of Contents for S4TEF10xx-10x

Page 1: ...r Interference by Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference in commercial and or industrial areas When used in a residential area or in an adjacen...

Page 2: ...cal Support Technical support is available 24 hours a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Transition Now Chat live via the Web with Transition Networks Technical Support L...

Page 3: ...m DSX 1 100 ohm 133 266 ft 40 5 81 m 1 2 DS1 100 ohm 0 dB LBO DS1 100 ohm 7 5 dB LBO DSX 1 100 ohm 533 655 ft 162 200 m J1 110 ohm 0 655 ft 0 200 m 3 E1 120 ohm DS1 100 ohm 15 dB LBO DS1 100 ohm 22 5...

Page 4: ...nagement mode See the SNMP section for the commands that are supported via the RS 232 connector up down Enable Disable 9 up down Data port mode Local management mode 10 Troubleshooting Continued 5 Is...

Page 5: ...by determining the answers to the following questions and then taking the indicated action 1 Is the PWR LED illuminated NO Ensure that the power adapter is the proper type of voltage and cycle frequen...

Page 6: ...d temp models 105 106 07 108 Storage Temperature 40 to 85 C 40 to 185 F Humidity 5 to 95 non condensing Warranty Lifetime The information contained in this user s guide is subject to change For the mo...

Page 7: ...e the jumper to the desired position see above 4 Carefully replace the cover on the Device and replace the four 4 screws that secure the cover to the Device Power the Device 1 Connect the barrel conne...

Page 8: ...he cable to the RS 232 port on a computer or other device that is used to collect and display data Cable Specifications Continued T1 E1 Cable Category 3 minimum requirement Connector RJ 48C Electrical...

Page 9: ...ensitivity min 30 0 dBm max 14 0 dBm Link Budget 11 0 dB S4TEF1013 100 105 1300 nm multimode Fiber Optic Transmitter Power min 19 0 dBm max 14 0 dBm Fiber Optic Receiver Sensitivity min 30 0 dBm max 1...

Page 10: ...chassis The SNMP section below lists the commands that can be used to monitor and manage a networked S4TEF10xx 10x Device at a remote location For more details see the C4TEF10xx 10x user s guide on li...