background image

FAULT ISOLATION and CORRECTION

If the E-FX-HB-xx00 fails, isolate and correct the fault by determining the
answers to the following questions and then taking the indicated action:

1.

Is the P(o)W(e)R LED on the E-FX-HB-xx00 illuminated?
NO

Is the power cord properly installed in the E-FX-HB-xx00 and in the
grounded AC outlet?

Does the grounded AC outlet provide power?

Contact Technical Support: (800) 260-1312.

YES

Continue at step 2.

2.

Is a backbone uplink adapter installed at E-FX-HB-xx00 back? 
NO

Continue at step 7.

YES

Continue at step 3.

3.

Is the B(ack)B(one) STAT(us) LED illuminated continuously?
YES

Continue at step 7.

NO

Continue at step 4.

4.

Does the B(ack)B(one) STAT(us) LED blink on and off?
YES

Ensure that backbone uplink adapter is firmly connected.

Check backbone uplink cables for proper cabling and connection(s).

Ensure that device at remote end of network link is powered.

Contact Technical Support: (800) 260-1312.

NO

Continue at step 5.

5.

Is the B(ack)B(one) STAT(us) LED dark?
YES

The port is partitioned or isolated; investigate the device at the far
end of the link.

Contact Technical Support: (800) 260-1312.

NO

Continue at step 6.

6.

Is the B(ack)B(one) ACT(ivity) LED illuminated?
NO

Disconnect and reconnect the backbone cable to restart the
initialization process.

Restart the attached network device to restart the initialization
process.

Contact Technical Support: (800) 260-1312.

Optionally Install Backbone Uplink Adapter

WARNING: Remove AC line cord from power source before installing
backbone uplink adaptor in E-FX-HB-xx00. Failure to observe this warning
could result in personal injury or death.

CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing backbone uplink adaptor in the E-FX-HB-xx00.
Failure to observe this caution could result in damage to, and subsequent
failure of, backbone uplink adaptor.

To install the backbone uplink adapter in the E-FX-HB-xx00:

1.

Locate backbone uplink adapter plate at back of E-FX-HB-xx00.

2.

Remove backbone uplink adapter plate by using flatblade
screwdriver to remove two (2) screws that secure backbone uplink
adapter plate to back of E-FX-HB-xx00.

NOTE: Retain screws for step 5. (Optionally discard backbone
uplink adapter plate.)

3.

Carefully slide backbone uplink adapter, component side up, into
installation space revealed by removal of backbone uplink adapter
plate.

CAUTION: Do NOT force connection. Failure to observe this caution

could result in equipment damage and subsequent failure.

4.

Press component on backbone uplink adapter securely against
internal mating E-FX-HB-xx00 component until backbone uplink
adapter faceplate is flat against E-FX-HB-xx00 back.

5.

Secure backbone uplink adapter by installing retained screws
through backbone uplink adapter into E-FX-HB-xx00 chassis back.

Backbone Uplink Adapter Plate

Summary of Contents for E-FX-HB-0800

Page 1: ... harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassan...

Page 2: ...HB 1600 or E FX HB 0800 to which this declaration refers is in conformity with the following standards EMC CISPR 22 1985 Class A EN 55022 1988 Class A EN 50082 1 1992 EN 60950 A4 1997 IEC 801 2 IEC 801 3 and IEC 801 4 IEC 950 I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s _November 10 1999_____ Stephen Anderson Vice President of...

Page 3: ...times To calculate a collision domain round trip delay in bit times find the longest path between any two terminal devices in the collision domain Calculate the round trip delay by multiplying the length of the cable in meters by the delay per meter in bit times BT then take the sum of all cable delays plus station DTE repeater and multi port media converter port delays If the result is less than ...

Page 4: ...n adapter securely against internal mating E FX HB xx00 component until expansion adapter faceplate is flat against E FX HB xx00 chassis 5 Secure expansion adapter by installing retained screws through expansion adapter into E FX HB xx00 chassis YES Continue at step 7 7 Is one or more of the 100BASE FX STAT us LEDs illuminated continuously YES Continue at step 10 NO Continue at step 8 8 Does one o...

Page 5: ... to restart the initialization process Contact Technical Support 800 260 1312 Optionally Install Backbone Uplink Adapter WARNING Remove AC line cord from power source before installing backbone uplink adaptor in E FX HB xx00 Failure to observe this warning could result in personal injury or death CAUTION Wear a grounding device and observe electrostatic discharge precautions when installing backbo...

Page 6: ...rubber foot Position and secure each rubber foot as shown 3 Return E FX HB xx00 to upright position OPERATION Use the status LEDs to monitor E FX HB xx00 operation in the network HUB INDICATORS P o W e R Steady LED indicates E FX HB xx00 is connected to external AC power COL lision Flashing LED indicates network collisions G lobal F ault S tatus Steady LED indicates the presence of a partitioned o...

Page 7: ... one end of adapter cable to UPPER connector on expansion adapter on lowest hub in stack 3 Install one end of adapter cable to LOWER connector on expansion adapter on next hub in stack 4 Continue steps 2 3 until installation is complete AT FRONT To cascade hubs by installing fiber cables between hubs 1 Locate or build 100BASE FX compliant two stranded fiber cable with appropriate TX to RX connecto...

Page 8: ...cate 100BASE FX uplink adapter installed at E FX HB xx00 back See page 5 2 Locate or build 100BASE FX compliant fiber cable with male two stranded TX to RX connectors at both ends See page 14 3 Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors respectively on E FX HB xx00 100BASE FX uplink adapter 4 Connect male TX and RX cable connectors at other end of ca...