background image

INSTALLATION 

Optionally Install Expansion Adapter

WARNING: Remove AC line cord from power source before installing
expansion adaptor in E-FX-HB-xx00. Failure to observe this warning could
result in personal injury or death.

CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing Expansion Adapter in the E-FX-HB-xx00. Failure
to observe this caution could result in damage to, and subsequent failure of,
Expansion Adapter.

To install the expansion adapter in the E-FX-HB-xx00:

1.

Locate expansion adapter plate at back of E-FX-HB-xx00.

2.

Remove expansion adapter plate by using flatblade screwdriver to
remove two (2) screws that secure expansion adapter plate to back
of E-FX-HB-xx00.

NOTE: Retain screws for step 5. (Optionally discard expansion
adapter plate.)

3.

Carefully slide expansion adapter, component side up, into
installation space revealed by removal of expansion adapter plate.

CAUTION: Do NOT force the connection. Failure to observe this

caution could result in equipment damage and subsequent failure.

4.

Press component on expansion adapter securely against internal
mating E-FX-HB-xx00 component until expansion adapter faceplate
is flat against E-FX-HB-xx00 chassis.

5.

Secure expansion adapter by installing retained screws through
expansion adapter into E-FX-HB-xx00 chassis.

YES

Continue at step 7.

7.

Is one (or more) of the 100BASE-FX STAT(us) LEDs illuminated
continuously?
YES

Continue at step 10

NO

Continue at step 8.

8.

Does one (or more) of the 100BASE-FX STAT(us) LEDs blink on
and off?
YES

Check fiber cables for proper connection.

Verify that TX and RX cables on E-FX-HB-xx00 are connected to RX
and TX ports, respectively, on terminal device. (See page 9.)

Ensure that terminal device(s) is/are powered.

Contact Technical Support: (800) 260-1312.

NO

Continue at step 9.

9.

Is one (or more) of the 100BASE-FX STAT(us) LEDs dark?
YES

The port is (or ports are) partitioned; investigate the attached
terminal device(s).

Contact Technical Support: (800) 260-1312.

NO

Continue at step 10.

10.

Is one (or more) of the 100BASE-FX ACT(ivity) LEDs
illuminated?
YES

The port is (or ports are) operational and receiving data.

NO

Disconnect and reconnect the 100BASE-FX cable to restart the
initialization process.

Restart the terminal device(s) to restart the initialization process.

Contact Technical Support: (800) 260-1312.

Expansion Adapter Plate

Summary of Contents for E-FX-HB-0800

Page 1: ... harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassan...

Page 2: ...HB 1600 or E FX HB 0800 to which this declaration refers is in conformity with the following standards EMC CISPR 22 1985 Class A EN 55022 1988 Class A EN 50082 1 1992 EN 60950 A4 1997 IEC 801 2 IEC 801 3 and IEC 801 4 IEC 950 I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s _November 10 1999_____ Stephen Anderson Vice President of...

Page 3: ...times To calculate a collision domain round trip delay in bit times find the longest path between any two terminal devices in the collision domain Calculate the round trip delay by multiplying the length of the cable in meters by the delay per meter in bit times BT then take the sum of all cable delays plus station DTE repeater and multi port media converter port delays If the result is less than ...

Page 4: ...n adapter securely against internal mating E FX HB xx00 component until expansion adapter faceplate is flat against E FX HB xx00 chassis 5 Secure expansion adapter by installing retained screws through expansion adapter into E FX HB xx00 chassis YES Continue at step 7 7 Is one or more of the 100BASE FX STAT us LEDs illuminated continuously YES Continue at step 10 NO Continue at step 8 8 Does one o...

Page 5: ... to restart the initialization process Contact Technical Support 800 260 1312 Optionally Install Backbone Uplink Adapter WARNING Remove AC line cord from power source before installing backbone uplink adaptor in E FX HB xx00 Failure to observe this warning could result in personal injury or death CAUTION Wear a grounding device and observe electrostatic discharge precautions when installing backbo...

Page 6: ...rubber foot Position and secure each rubber foot as shown 3 Return E FX HB xx00 to upright position OPERATION Use the status LEDs to monitor E FX HB xx00 operation in the network HUB INDICATORS P o W e R Steady LED indicates E FX HB xx00 is connected to external AC power COL lision Flashing LED indicates network collisions G lobal F ault S tatus Steady LED indicates the presence of a partitioned o...

Page 7: ... one end of adapter cable to UPPER connector on expansion adapter on lowest hub in stack 3 Install one end of adapter cable to LOWER connector on expansion adapter on next hub in stack 4 Continue steps 2 3 until installation is complete AT FRONT To cascade hubs by installing fiber cables between hubs 1 Locate or build 100BASE FX compliant two stranded fiber cable with appropriate TX to RX connecto...

Page 8: ...cate 100BASE FX uplink adapter installed at E FX HB xx00 back See page 5 2 Locate or build 100BASE FX compliant fiber cable with male two stranded TX to RX connectors at both ends See page 14 3 Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors respectively on E FX HB xx00 100BASE FX uplink adapter 4 Connect male TX and RX cable connectors at other end of ca...

Reviews: