Install E-FX-HB-xx00 at Site

WARNING: During the site installation, handle the E-FX-HB-xx00 in such a
way that the E-FX-HB-xx00 does not fall. Failure to observe this warning
could result in injury to personnel and/or equipment damage.

NOTE: If E-FX-HB-xx00 is shipped with brackets installed, proceed to step 2.

To install the E-FX-HB-xx00 in 19-inch rack cabinet:

1.

Remove and retain two (2) screws located at front left side and front
right side of E-FX-HB-xx00 chassis. Install right and left front
brackets (provided) on chassis by installing two (2) retained screws
through each bracket into chassis.

2.

Carefully align E-FX-HB-xx00 between 19-inch rack mounting rails.

3.

Install E-FX-HB-xx00 by installing two (2) screws through right front
bracket into rack and two (2) screws through left front bracket into
rack, using clip nuts (NOT provided) to secure, if necessary.

To install the E-FX-HB-xx00 on table or other flat surface:

NOTE: Rubber feet are provided.

1.

Carefully turn E-FX-HB-xx00 to side.

2.

Install four (4) rubber feet:

Separate rubber feet.

Remove protective paper
from adhesive
surface on rubber
foot.

Position and
secure each
rubber foot as
shown.

3.

Return E-FX-HB-xx00 to upright position. 

OPERATION 

Use the status LEDs to monitor E-FX-HB-xx00 operation in the network. 

HUB INDICATORS

P(o)W(e)R

Steady LED indicates E-FX-HB-xx00 is
connected to external AC power.

COL(lision)

Flashing LED indicates network collisions.

G(lobal) F(ault) S(tatus)

Steady LED indicates the presence of a
partitioned or isolated port. (A port is
partitioned automatically after a collision
occurs during 60 or more consecutive
attempts to transmit to the port; a port is
isolated if more then two consecutive false
carrier events are received.) 

NOTE: The hub unpartitions/unisolates the
port when network traffic becomes normal.
The GFS LED remains illuminated until the
partition/isolation condition is corrected.)

B(ack)B(one) & 100BASE-FX INDICATORS

STAT(us)

Steady LED indicates, for each port, a valid
link and no partition or isolation.

Dark LED indicates, for each port, that port
is not linked, is isolated, or is partitioned.

ACT(ivity)

Flashing LED indicates, for each port,
reception of data packet(s).

STAT

PWR

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

1

3

2

1

3

2

STAT

PWR

4

5

7

6

8

9

11

10

12

13

15

14

16

COL

ACT

100BASE-FX

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

ACT

STAT

GFT

BB

Summary of Contents for E-FX-HB-0800

Page 1: ... harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le présent appareil numérique n émet pas de bruits radioélectriques dépassan...

Page 2: ...HB 1600 or E FX HB 0800 to which this declaration refers is in conformity with the following standards EMC CISPR 22 1985 Class A EN 55022 1988 Class A EN 50082 1 1992 EN 60950 A4 1997 IEC 801 2 IEC 801 3 and IEC 801 4 IEC 950 I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s _November 10 1999_____ Stephen Anderson Vice President of...

Page 3: ...times To calculate a collision domain round trip delay in bit times find the longest path between any two terminal devices in the collision domain Calculate the round trip delay by multiplying the length of the cable in meters by the delay per meter in bit times BT then take the sum of all cable delays plus station DTE repeater and multi port media converter port delays If the result is less than ...

Page 4: ...n adapter securely against internal mating E FX HB xx00 component until expansion adapter faceplate is flat against E FX HB xx00 chassis 5 Secure expansion adapter by installing retained screws through expansion adapter into E FX HB xx00 chassis YES Continue at step 7 7 Is one or more of the 100BASE FX STAT us LEDs illuminated continuously YES Continue at step 10 NO Continue at step 8 8 Does one o...

Page 5: ... to restart the initialization process Contact Technical Support 800 260 1312 Optionally Install Backbone Uplink Adapter WARNING Remove AC line cord from power source before installing backbone uplink adaptor in E FX HB xx00 Failure to observe this warning could result in personal injury or death CAUTION Wear a grounding device and observe electrostatic discharge precautions when installing backbo...

Page 6: ...rubber foot Position and secure each rubber foot as shown 3 Return E FX HB xx00 to upright position OPERATION Use the status LEDs to monitor E FX HB xx00 operation in the network HUB INDICATORS P o W e R Steady LED indicates E FX HB xx00 is connected to external AC power COL lision Flashing LED indicates network collisions G lobal F ault S tatus Steady LED indicates the presence of a partitioned o...

Page 7: ... one end of adapter cable to UPPER connector on expansion adapter on lowest hub in stack 3 Install one end of adapter cable to LOWER connector on expansion adapter on next hub in stack 4 Continue steps 2 3 until installation is complete AT FRONT To cascade hubs by installing fiber cables between hubs 1 Locate or build 100BASE FX compliant two stranded fiber cable with appropriate TX to RX connecto...

Page 8: ...cate 100BASE FX uplink adapter installed at E FX HB xx00 back See page 5 2 Locate or build 100BASE FX compliant fiber cable with male two stranded TX to RX connectors at both ends See page 14 3 Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors respectively on E FX HB xx00 100BASE FX uplink adapter 4 Connect male TX and RX cable connectors at other end of ca...

Reviews: