background image

INSTALLATION

(continued)

Install Cable

FIBER

1.

Locate or build fiber cables that are compliant with specifications
on page __, with male two-stranded TX to RX connectors installed
at both ends.

2.

Connect cable with connector installed at TX location on media
converter to RX location on attached device.

3.

Connect cable with connector installed at RX location on media
converter to TX location on attached device.

COPPER

E1 75 OHM (COAX CONNECTOR)

NOTE: Ground coax segment to earth ground at one end.

Locate or build coax cables  that are compliant with specifications
on page 10.

Connect BNC connector at one end of cable to media converter.

Connect BNC connector at other end of cable to network
equipment.

Power the Slide-In-Module Media Converter

NOTE: The Slide-In-Module is powered through the media conversion
center.

OPERATION 

Status LEDs

Use the status LEDs to monitor media converter operation in the network. 

SDC

Signal Detect/Copper

- Steady LED indicates twisted-pair

copper link is up.

Flashing LED (once/second)
indicates transmitting All Ones
(AIS) on link if 

fiber

link (switch

selectable) is down.

Flashing LED (5 times/second) indicates All Ones detected on
Link.

SDF

Signal Detect/Fiber

- Steady LED indicates fiber link is up.

Flashing LED (once/second) indicates transmitting All Ones
(AIS) on link if 

copper

link (switch selectable) is down.

Flashing LED (5 times/second) indicates All Ones detected on
Link.

P(o)W(e)R

Steady green LED indicates connection to external AC power.

Using SNMP*

Use SNMP at an attached terminal or at a remote location to:

Monitor media converter by monitoring:

Media Converter Power

Fiber Link Status

Copper Link Status

Hardware Switch settings

AIS detected on Fiber

AIS detected on Copper

Enter network commands that:

Enable/disable Loop-back on Fiber 

Enable/disable Transmit All Ones on Fiber when Copper is down 

Enable/disable Transmit All Ones on Copper when Fiber is down

Power Down Media Converter. 

*See the on-line documentation that comes with TRANSITION Networks
FocalPoint

software for applicable commands and usage.

CSDTF30xx

7

Summary of Contents for CSDTF3011-110

Page 1: ...es Trademark Notice All registered trademarks and trademarks are the property of their respective owners Copyright Restrictions 2001 TRANSITION Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S A 33219 A 12 TRANSITION Networks CSDTF30xx 110 s...

Page 2: ...e 0 10 000 feet Warranty Lifetime Operating temperature range for this Slide In Module depends on the physical characteristics and the installation configuration of the TRANSITION Networks chassis in which this Slide In Module will be installed See the User s Guide for the chassis in which this Slide In Module will be installed for a discussion of temperature related installation constraints CSDTF...

Page 3: ...pback switch facilitates installation and network debug procedures The path for the CSDTF30xx loopback is shown TRANSMIT ALL ONES FUNCTION A selectable Transmit All Ones switch on the fiber interface AND on the copper interface allows for insertion of an all ones pattern on the interface whenever signal detect is lost The all ones pattern creates an alarm condition at the equipment connected to th...

Page 4: ...M Fiber Optic Transmitter Power min 14 0 dBm max 12 0 dBm Fiber Optic Receiver Sensitivity min 25 0 dBm max 12 0 dBm Typical Maximum Cable Distance 2 kilometers CSDTF3013 110 850 nM Fiber optic Transmitter Power min 14 0 dBm max 12 0 dBm Fiber optic Receiver Sensitivity min 25 0 dBm max 12 0 dBm Typical Maximum Cable Distance 2 kilometers SINGLEMODE Fiber Optic Cable Recommended 9 µm singlemode fi...

Page 5: ... to media converter by coax cable Contact Technical Support 800 260 1312 YES Contact Technical Support 800 260 1312 Install Slide In Module s CAUTION Wear a grounding device and observe electrostatic discharge precautions when installing Media Converter Slide in Module s in the media conversion center Failure to observe this caution could result in damage to and subsequent failure of the Media Con...

Page 6: ... Copper Steady LED indicates twisted pair copper link is up Flashing LED once second indicates transmitting All Ones AIS on link if fiber link switch selectable is down Flashing LED 5 times second indicates All Ones detected on Link SDF Signal Detect Fiber Steady LED indicates fiber link is up Flashing LED once second indicates transmitting All Ones AIS on link if copper link switch selectable is ...

Reviews: