Transition Networks CSDTF3011-110 User Manual Download Page 2

CSDTF30xx IN THE NETWORK

NOTE: E1 MEDIA CONVERTERS MUST BE USED IN PAIRS. A TRANSITION
Networks CSDTF30xx stand-alone media converter can be used with another
CSDTF30xx stand-alone media converter, with a SSDTF30xx chassis media
converter, or with a previous model TRANSITION Networks T1/E1 media
converter, such as a C/T1E1-CF-01 or a T1E1-CF-01.

Media converter is framing independent (as ESF vs D4) and supports all
common line codes, (AMI, B8ZS, HDB3). 

All Ones Insertion (AIS) on loss of signal at copper and/or fiber interface. 

TECHNICAL SPECIFICATIONS

Standards

Emissions: CISPR A

E1 Physical Layer: ITU-T, TBR12 British Technical
Publication: PD7024 (NTR4), ANSI, AT&T, ETSI, 
EN 45001

Dimensions

2.9" x 4.8" x 1.4" 

Weight

8 oz (approximate)

Power Consumption

5 watts

Environment

Typical Operating Temperature*: 0°

to 

50°C (32°

to 

122°F )

Storage Temperature:  

-20°

to 

85°C (-4° 

to 

185°F)

Humidity

10-90%, non condensing

Altitude

0-10,000 feet

Warranty

Lifetime

*Operating temperature range for this Slide-In-Module depends on the physical
characteristics and the installation configuration of the TRANSITION Networks
chassis in which this Slide-In-Module will be installed. See the User’s Guide 

for

the chassis in which this Slide-In-Module will be installed

for a discussion of

temperature-related installation constraints. 

CSDTF30xx

11

2

DECLARATION OF CONFORMITY

Name of Mfg:

Transition Networks 

6475 City West Parkway, Minneapolis MN 55344 USA

Model:

CSDTF30xx Series E1 Coax Copper-to-Fiber Media Converter

Part Number:

CSDTF3011-110, CSDTF3012-110, CSDTF3013-110, 
CSDTF3014-110, CSDTF3015-110, CSDTF3022-110

Regulation:

EMC Directive 89/336/EEC

Purpose:  To declare that the

CSDTF30xx

to which this declaration refers is in

conformity with the following standards.

EN 55022:1994; EN 55024:1998; FCC Part 15 Class A; EN 60950 A4:1997; UL 1950

I, the undersigned, hereby declare that the equipment specified above conforms to the above

Directive(s) and Standard(s).

_July 8, 2001_____

Stephen Anderson, Vice-President of Engineering

Date

Summary of Contents for CSDTF3011-110

Page 1: ...es Trademark Notice All registered trademarks and trademarks are the property of their respective owners Copyright Restrictions 2001 TRANSITION Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from TRANSITION Networks Printed in the U S A 33219 A 12 TRANSITION Networks CSDTF30xx 110 s...

Page 2: ...e 0 10 000 feet Warranty Lifetime Operating temperature range for this Slide In Module depends on the physical characteristics and the installation configuration of the TRANSITION Networks chassis in which this Slide In Module will be installed See the User s Guide for the chassis in which this Slide In Module will be installed for a discussion of temperature related installation constraints CSDTF...

Page 3: ...pback switch facilitates installation and network debug procedures The path for the CSDTF30xx loopback is shown TRANSMIT ALL ONES FUNCTION A selectable Transmit All Ones switch on the fiber interface AND on the copper interface allows for insertion of an all ones pattern on the interface whenever signal detect is lost The all ones pattern creates an alarm condition at the equipment connected to th...

Page 4: ...M Fiber Optic Transmitter Power min 14 0 dBm max 12 0 dBm Fiber Optic Receiver Sensitivity min 25 0 dBm max 12 0 dBm Typical Maximum Cable Distance 2 kilometers CSDTF3013 110 850 nM Fiber optic Transmitter Power min 14 0 dBm max 12 0 dBm Fiber optic Receiver Sensitivity min 25 0 dBm max 12 0 dBm Typical Maximum Cable Distance 2 kilometers SINGLEMODE Fiber Optic Cable Recommended 9 µm singlemode fi...

Page 5: ... to media converter by coax cable Contact Technical Support 800 260 1312 YES Contact Technical Support 800 260 1312 Install Slide In Module s CAUTION Wear a grounding device and observe electrostatic discharge precautions when installing Media Converter Slide in Module s in the media conversion center Failure to observe this caution could result in damage to and subsequent failure of the Media Con...

Page 6: ... Copper Steady LED indicates twisted pair copper link is up Flashing LED once second indicates transmitting All Ones AIS on link if fiber link switch selectable is down Flashing LED 5 times second indicates All Ones detected on Link SDF Signal Detect Fiber Steady LED indicates fiber link is up Flashing LED once second indicates transmitting All Ones AIS on link if copper link switch selectable is ...

Reviews: