background image

CPSMP-120

6

24-hour Technical Support: 

1-800-260-1312

-- International: 

00-1-952-941-7600

Replace the CPSMP-120 -- 

Continued

6.

Carefully slide the replacement power supply module into the installation
slot, aligning the module with the installation guides.  

7.

Ensure that the power supply module is firmly seated inside the chassis.

8.

Rotate the attached panel fastener screw clockwise to secure the power
supply module to the chassis.

9.

See the “Connect to External Power” section (page 4) for instructions on
re-connecting the power supply module to the external power source.

I

0

I

0

Panel
Fastener
Screw

7

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

Replace the Fuse

CAUTION:  Ensure that the power supply module has been disconnected
from the external power source and the module’s On/Off switch has been
set to “0”.  Failure to observe this caution could result in damage to, and
subsequent failure of, the power supply module.

NOTE:

The CPSMP-120 power supply module may be “hot swapped” (i.e.,

serviced while the chassis is in operation) 

provided the module to be serviced

has been disconnected from its external power supply and the module’s
On/Off switch has been set to “0”.

To replace the fuse in the CPSMP-120 power supply module:

1.

Ensure the On/Off switch on the power supply module is set to 

“0”

.

2.

Disconnect the the male end of the AC power cord from the AC rack or
wall socket.

3.

Disconnect the female end of the AC power cord from the external power
connector.

4.  From the inside edge of the power receptacle, insert a small flat blade

screwdriver into the groove on the front, inside edge of the fuse holder
and carefully pry the fuse holder from the power supply module.

5.

Carefully remove the fuse from the fuse holder.

6.

Install a 

same size and rating

replacement fuse in the fuse holder.

7.

Return the fuse holder and fuse to the installation position in the power
supply module. Snap the fuse holder into place.

8.

See the “Connect to External Power” section (page 4) for instructions on
re-connecting the power supply module to the external power source.

Power

LED

On/Off

Switch

I

0

I

0

Fuse Holder

Fuse

Summary of Contents for CPSMP-120

Page 1: ...the power supply module to supply power to the chassis and any installed modules A panel fastener screw that secures the power supply module to the chassis A power LED indicator A handle for installing and removing the power supply module to from the chassis A fuse installed in a fuse holder An external power connector that supplies power from a standard AC wall outlet I 0 I 0 Power LED On Off Swi...

Page 2: ...nal power source before installing it into the chassis Failure to observe this caution could result in equipment damage and or personal injury or death Install the CPSMP 120 CAUTION Ensure that the power supply module has been disconnected from the external power source and the module s On Off switch has been set to 0 Failure to observe this caution could result in damage to and subsequent failure...

Page 3: ...connect the power supply module to the external power source before installing it into the chassis Failure to observe this caution could result in equipment damage and or personal injury or death Replace the CPSMP 120 CAUTION Ensure that the power supply module has been disconnected from the external power source and the module s On Off switch has been set to 0 Failure to observe this caution coul...

Page 4: ...MP 120 power supply module may be hot swapped i e serviced while the chassis is in operation provided the module to be serviced has been disconnected from its external power supply and the module s On Off switch has been set to 0 To replace the fuse in the CPSMP 120 power supply module 1 Ensure the On Off switch on the power supply module is set to 0 2 Disconnect the the male end of the AC power c...

Page 5: ...l be installed For the most up to date information on the CPSMP 120 power supply module view the user s guide on line at www transition com 9 techsupport transition com Click the Transition Now link for a live Web chat Troubleshooting If the power supply module fails isolate and correct the failure by determining the answers to the following questions and then taking the indicated action 1 Is the ...

Page 6: ... Mark1 FCC Regulations This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and use...

Page 7: ...ir respective owners Copyright Restrictions 2001 2004 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the U S A 33209 C ...

Reviews: