Transition Networks CPSMP-120 User Manual Download Page 2

CPSMP-120

2

24-hour Technical Support: 

1-800-260-1312

-- International: 

00-1-952-941-7600

CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing or servicing the power supply module.  Failure to
observe this caution could result in damage to, and subsequent failure of, the
power supply module.

CPSMP-120 in the 13-Slot Chassis

The CPSMP-120 power supply module may replace an existing CPSMP-120
module or be installed in the second installation slot (see drawing below) of the

CPSMC1300-100

13-slot chassis to become the optional, redundant power

supply.

NOTE:

The CPSMP-120 power supply module may also be installed as the

redundant power supply in 

either 

DC-powered 13-slot chassis:

CPSMC1310-100 (48-VDC chassis)

CPSMC1320-100 (24-VDC chassis)

For more information, see the user’s guide for the CPSMC13xx-100 13-slot
chassis on-line at:  www.transition.com.

AC Power

Supply

I

0

Second

Installation Slot

3

[email protected]

-- Click the 

“Transition Now”

link for a live Web chat.

WARNING: Do not connect the power supply module to the external power
source before installing it into the chassis.  Failure to observe this caution could
result in equipment damage and/or personal injury or death.

Install the CPSMP-120

CAUTION:  Ensure that the power supply module has been disconnected
from the external power source and the module’s On/Off switch has been
set to “0”.  Failure to observe this caution could result in damage to, and
subsequent failure of, the power supply module.

NOTE:

The CPSMP-120 power supply module may be “hot swapped” (i.e.,

installed in the chassis while the chassis is in operation) 

provided the module

to be installed has been disconnected from its external power source and the
module’s On/Off switch has been set to “0”.

To install the CPSMP-120 power supply module into the CPSMC13xx-100
chassis:

1.

Loosen the screw that secures the protective plate to the chassis and pull
the plate away from the chassis.

2.

Ensure the On/Off switch on the power supply module is set to 

“0”

.

3.

Carefully slide the power supply module into the installation slot,
aligning the module with the installation guides.  

4.

Ensure that the power supply module is firmly seated inside the chassis.

5.

Rotate the attached panel fastener screw clockwise to secure the power
supply module to the chassis.

I

0

I

0

I

0

Panel
Fastener
Screw

Summary of Contents for CPSMP-120

Page 1: ...the power supply module to supply power to the chassis and any installed modules A panel fastener screw that secures the power supply module to the chassis A power LED indicator A handle for installing and removing the power supply module to from the chassis A fuse installed in a fuse holder An external power connector that supplies power from a standard AC wall outlet I 0 I 0 Power LED On Off Swi...

Page 2: ...nal power source before installing it into the chassis Failure to observe this caution could result in equipment damage and or personal injury or death Install the CPSMP 120 CAUTION Ensure that the power supply module has been disconnected from the external power source and the module s On Off switch has been set to 0 Failure to observe this caution could result in damage to and subsequent failure...

Page 3: ...connect the power supply module to the external power source before installing it into the chassis Failure to observe this caution could result in equipment damage and or personal injury or death Replace the CPSMP 120 CAUTION Ensure that the power supply module has been disconnected from the external power source and the module s On Off switch has been set to 0 Failure to observe this caution coul...

Page 4: ...MP 120 power supply module may be hot swapped i e serviced while the chassis is in operation provided the module to be serviced has been disconnected from its external power supply and the module s On Off switch has been set to 0 To replace the fuse in the CPSMP 120 power supply module 1 Ensure the On Off switch on the power supply module is set to 0 2 Disconnect the the male end of the AC power c...

Page 5: ...l be installed For the most up to date information on the CPSMP 120 power supply module view the user s guide on line at www transition com 9 techsupport transition com Click the Transition Now link for a live Web chat Troubleshooting If the power supply module fails isolate and correct the failure by determining the answers to the following questions and then taking the indicated action 1 Is the ...

Page 6: ... Mark1 FCC Regulations This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and use...

Page 7: ...ir respective owners Copyright Restrictions 2001 2004 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the U S A 33209 C ...

Reviews: