background image

CFETF10xx-205

4

24-hour Technical Support: 1-800-260-1312   International: 00-1-952-941-7600 

[email protected] -- Click the “Transition Now” link for a live Web chat.

13

Installation 

-- Continued

Set the AutoCross™ Jumper

When the AutoCross feature is activated, it allows either straight-through or
crossover cables to be used when connecting to 100Base-TX devices.
AutoCross determines the characteristics of the connection and automatically
configures the unit to link up, regardless of the cable configuration.

The jumper is located on the circuit board labeled “D” and “E”.

Use small needle-nose pliers to remove and position the jumper.    

Disable

Either straight-through or crossover

twisted-pair copper cable must be
installed, according to the site
requirements.

Enable

The media converter connects

automatically to either straight-through or
crossover twisted-pair copper cable.

NOTE:

AutoCross is enabled by default.” Transition networks recommends

leaving the jumper in the “enable” position.

Install the media converter

CAUTION:  

Wear a grounding device and observe electrostatic discharge

precautions when installing the CFETF10xx-205 media converter. Failure to
observe this caution could result in damage to or  failure of, the media converter.

1.

Carefully slide the media converter into the  slot, aligning it with the slot
guides.  

2.

Ensure that the converter is firmly seated into the slot.

3.

Push in and rotate the attached panel fastener screw clockwise to secure
the converter to the chassis.

 Me

d

ia Conve

rt

e

r

Poin

t

 

S

y

st

em Cha

ss

i

s

Panel Fa

st

ene

r

S

lo

t

D

Enable Au

t

oC

r

o

ss

Di

s

able Au

t

oC

r

o

ss

E

D

E

Troubleshooting

If the media converter fails, isolate and correct the failure by determining the
answers to the following questions and then taking the indicated action:

1.

Is the PWR LED on the media converter illuminated?
NO

Is the media converter installed properly in the chassis?

Is the power cord properly installed in the chassis and at the external
power source?

Does the external power source provide power?

Contact Technical Support: 1-800-260-1312 

(Int’l: 00-1-952-7600)

.

YES

Proceed to step 2.

2.

Is the LKC LED on the media converter illuminated?
NO

Check the twisted-pair cables for proper connection.

Contact Technical Support: 1-800-260-1312

(Int’l: 00-1-952-7600).

YES

Proceed to step 3.

3.

Is the LKF LED on the media converter illuminated?
NO

Check the fiber cables for proper connection.

Verify that the TX and RX cables on the media converter are
connected to the RX and TX ports, respectively, on the other device.

Contact Technical Support: 1-800-260-1312 

(Int’l: 00-1-952-7600)

.

YES

Proceed to step 4.

4.

Is the RXC LED on the media converter flashing?
NO

If there is no activity on the 100Base-TX port, proceed to step 5.

If there is activity on the 100Base-TX port, disconnect and reconnect
the 100Base-TX cable to restart the initialization process.

Restart the workstation to restart the initialization process.

Contact Technical Support: 1-800-260-1312

(Int’l: 00-1-952-7600)

.

YES

Proceed to step 5.

5.

Is the RXF LED on the media converter flashing?
NO

If there is activity on the 100Base-FX port, disconnect and reconnect
the 100Base-FX cable to restart the initialization process.

Verify that the TX and RX cables on the media converter are
connected to the RX and TX ports, respectively, on the other device.

Restart the workstation to restart the initialization process.

Contact Technical Support: 1-800-260-1312 

(Int’l: 00-1-952-7600)

.

YES

Contact Technical Support: 1-800-260-1312 (Int’l: 00-1-952-7600).

Summary of Contents for CFETF1011-205

Page 1: ...5 RJ 45 100 m 328 ft SC 1310 nm single mode 20 km 12 4 miles CFETF1015 205 RJ 45 100 m 328 ft SC 1310 nm single mode 40 km 24 9 miles CFETF1016 205 RJ 45 100 m 328 ft SC 1310 nm single mode 60 km 32 3 miles CFETF1017 205 RJ 45 100 m 328 ft SC 1550 nm single mode 80 km 49 7 miles CFETF1018 205 RJ 45 100 m 328 ft MT RJ 1300 nm multimode 2 km 1 2 miles CFETF1019 205 RJ 45 100 m 328 ft LC 1310 nm sing...

Page 2: ...prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in damage to the public telephone network Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verstösst geg...

Page 3: ... Software Software controls the function of the board The DIP switches do not function in software mode Hardware Mode Software Mode H H S S Link Pass Through up enabled Pause up enabled Auto Negotiation up enabled Far End Fault up enabled 1 2 3 4 Contact Us Technical Support Technical support is available 24 hours a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Transition Now Ch...

Page 4: ...ate and correct the failure by determining the answers to the following questions and then taking the indicated action 1 Is the PWR LED on the media converter illuminated NO Is the media converter installed properly in the chassis Is the power cord properly installed in the chassis and at the external power source Does the external power source provide power Contact Technical Support 1 800 260 131...

Page 5: ...hown RX TX RX TX RJ 45 Port Media Converter RJ 45 Port On other device workstation switch etc Point System Chassis Technical Specifications For use with Transition Networks Model CFETF10xx 205 or equivalent Standards IEEE 802 3 Data Rate 100 Mb s Dimensions 3 4 x 5 0 x 0 87 86 x 185 x 22 mm Weight 3 oz 91 g approximate Power Consumption 3 5 watts 200 mA 13 9 VDC MTBF 382 956 hours MIL217F2 V5 0 MI...

Page 6: ...twork the maximum cable lengths are determined by the round trip delay limitations of each Fast Ethernet collision domain A collision domain is the longest path between any two terminal devices e g a terminal switch or router The 512 Bit Rule determines the maximum length of cable permitted by calculating the round trip delay in bit times BTU of a particular collision domain If the result is less ...

Page 7: ...ia converter B disables the copper link media converter A disables the copper link 3 4 2 1 4 1 Media Converter A Media Converter B Near End Device Far End Device original fault on the copper link media converter B disables the copper link media converter A disables the fiber TX link 3 2 media converter B loses the fiber RX link Cable Specifications The physical characteristics must meet or exceed ...

Page 8: ...ite blue orange white white orange etc Do not use flat or silver satin wire Straight Through Cable Crossover Cable Twisted Pair 1 Twisted Pair 2 Twisted Pair 2 Twisted Pair 1 Operation Continued SUMP See the on line documentation that comes with Transition Networks FocalPoint software for applicable commands and usage Use SUMP at an attached terminal or at a remote location to monitor the followin...

Reviews: