CFETF10xx-205

8

24-hour Technical Support: 1-800-260-1312   International: 00-1-952-941-7600 

[email protected] -- Click the “Transition Now” link for a live Web chat.

9

Cable Specifications

Copper Cable  

Category 5:  

(minimum requirement)

Gauge

24 to 22 AWG

Attenuation 

22.0 dB /100m @ 100 MHz

Maximum Cable Distance

100 meters

• Straight-through  or  crossover twisted-pair cable may be used.
• Shielded twisted-pair or unshielded twisted-pair may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• Use only dedicated wire pairs for the active pins:

(e.g., blue/white & white/blue, orange/white & white/orange, etc.)

• Do not use flat or silver satin wire.

Str

ai

g

h

t

-Th

r

ou

g

h Cable

C

r

o

ss

ove

r

 Cable

Twi

st

e

d

 Pai

r

 #1

Twi

st

e

d

 Pai

r

 #2

Twi

st

e

d

 Pai

r

 #2

Twi

st

e

d

 Pai

r

 #1

Operation

-- Continued

SUMP

See the on-line documentation that comes with Transition Networks

FocalPoint™

software for applicable commands and usage.

Use SUMP at an attached terminal or at a remote location to monitor the
following media converter activities:

Media-converter power

Copper link and fiber link status

Twisted-pair cable length

Hardware switch settings

Fault condition

Also, use SUMP to enter network commands that:

Enable/disable full-/half-duplex 

Enable/disable Link Pass-Through (LPT) 

Enable/disable Far-End Fault (FEF) 

Enable/disable Pause 

Enable/disable AutoCross 

Power down the media converter 

Summary of Contents for CFETF1011-205

Page 1: ...5 RJ 45 100 m 328 ft SC 1310 nm single mode 20 km 12 4 miles CFETF1015 205 RJ 45 100 m 328 ft SC 1310 nm single mode 40 km 24 9 miles CFETF1016 205 RJ 45 100 m 328 ft SC 1310 nm single mode 60 km 32 3 miles CFETF1017 205 RJ 45 100 m 328 ft SC 1550 nm single mode 80 km 49 7 miles CFETF1018 205 RJ 45 100 m 328 ft MT RJ 1300 nm multimode 2 km 1 2 miles CFETF1019 205 RJ 45 100 m 328 ft LC 1310 nm sing...

Page 2: ...prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in damage to the public telephone network Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verstösst geg...

Page 3: ... Software Software controls the function of the board The DIP switches do not function in software mode Hardware Mode Software Mode H H S S Link Pass Through up enabled Pause up enabled Auto Negotiation up enabled Far End Fault up enabled 1 2 3 4 Contact Us Technical Support Technical support is available 24 hours a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Transition Now Ch...

Page 4: ...ate and correct the failure by determining the answers to the following questions and then taking the indicated action 1 Is the PWR LED on the media converter illuminated NO Is the media converter installed properly in the chassis Is the power cord properly installed in the chassis and at the external power source Does the external power source provide power Contact Technical Support 1 800 260 131...

Page 5: ...hown RX TX RX TX RJ 45 Port Media Converter RJ 45 Port On other device workstation switch etc Point System Chassis Technical Specifications For use with Transition Networks Model CFETF10xx 205 or equivalent Standards IEEE 802 3 Data Rate 100 Mb s Dimensions 3 4 x 5 0 x 0 87 86 x 185 x 22 mm Weight 3 oz 91 g approximate Power Consumption 3 5 watts 200 mA 13 9 VDC MTBF 382 956 hours MIL217F2 V5 0 MI...

Page 6: ...twork the maximum cable lengths are determined by the round trip delay limitations of each Fast Ethernet collision domain A collision domain is the longest path between any two terminal devices e g a terminal switch or router The 512 Bit Rule determines the maximum length of cable permitted by calculating the round trip delay in bit times BTU of a particular collision domain If the result is less ...

Page 7: ...ia converter B disables the copper link media converter A disables the copper link 3 4 2 1 4 1 Media Converter A Media Converter B Near End Device Far End Device original fault on the copper link media converter B disables the copper link media converter A disables the fiber TX link 3 2 media converter B loses the fiber RX link Cable Specifications The physical characteristics must meet or exceed ...

Page 8: ...ite blue orange white white orange etc Do not use flat or silver satin wire Straight Through Cable Crossover Cable Twisted Pair 1 Twisted Pair 2 Twisted Pair 2 Twisted Pair 1 Operation Continued SUMP See the on line documentation that comes with Transition Networks FocalPoint software for applicable commands and usage Use SUMP at an attached terminal or at a remote location to monitor the followin...

Reviews: