Model 0403

12

3

Ethernet™ Pocket Hub™

0403 Ethernet Pocket Hub Connectors and
Status LEDs

RJ-45 Connectors

Four (4) 10BaseT RJ-45 jack
connectors are located at one
end of the 0403 Pocket Hub.
The RJ-45  jacks support
connection to shielded or
unshielded 100 ohm twisted
pair 10BaseT cable. 

BNC and Power Supply Adapter Connectors

An external power supply
adapter connector and a
BNC connector are located
at the other end of the 0403
Pocket Hub. The power
supply adapter connector
supplies external power. The
BNC connector supports one
connection to 10Base2
(thinnet) cable.

Status LEDs

Power and Link/Transmit
status LEDs are located at
the side of the 0403 Pocket
Hub. The Power LED
indicates connection to
power. The Link/ Transmit
LEDs track the four 0403
Pocket Hub connections to
10 BaseT.

5. MAINTENANCE

WARNING: DO NOT, UNDER ANY CIRCUMSTANCES,
open and attempt to repair the 0403 Pocket Hub or power
supply adapter unit.  Failure to observe this warning could
result in personal injury or death from electrical shock.

NOTE: Failure to observe the above warning will immediately void
the warranty.

Fault Isolation

If two network devices fail to communicate through the 0403
Pocket Hub, consider the following:

Are the LEDs described in the previous section functioning
properly?

Do network devices have Link Integrity enabled?

Do network devices communicate when the 0403 Pocket
Hub is not installed between them? 

Is flat or “silver satin” wire used in site internal wiring?

Are internal wiring patch cords, punch down blocks, and
wall jacks properly pinned or configured?

Is the thinnet cable unbroken and properly connected?

Are network interface cards properly configured?

Technical Support Contact

For assistance in fault isolation and in maintaining the 0403 Pocket
Hub, contact: 

TN Technical Support

(800) 260-1312

or your local distributor.

RJ-45 Connectors

BNC Connector

Power Supply Adapter
Connector

Status LEDs

Summary of Contents for 403

Page 1: ...ing using or maintaining the TRANSITION Networks Model 0403 Ethernet Pocket Hub contact TRANSITION Networks Technical Support at 800 260 1312 or contact your local distributor 7356 C Pocket Hub Ethernet E TBT HB 0403 Model 0403 ...

Page 2: ...No Problem Found TN s total liability in connection with the products and their installation to all persons and from all causes in the aggregate whether in contract tort or strict liability shall not exceed the amount paid to TN for the product directly related to the alleged damage However in no event shall TN have any liability to a customer or any third party for products manufactures according...

Page 3: ...om Internet http www transition com THE ABOVE WARRANTY IS EXCLUSIVE AND EXTENDS ONLY TO PRODUCTS ASSEMBLED BY TRANSITION NETWORKS INC TO THE EXTENT PERMITTED BY LAW TN DOES NOT MAKE AND DISCLAIMS ALL OTHER WARRANTIES EXCEPT TITLE EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF DESCRIPTION MERCHANTIBILITY FITNESS FOR A PARTICULAR PURPOSE OR NON INFRINGEMENT AND ANY WARRANTY BASED ...

Page 4: ...mble regeneration automatic polarity detection and correction Ethernet Pocket Hub 4 3 2 1 Power 1 2 3 4 E TBT 0403 Link Transmit n e t w o r k s T R A N S I T I O N Mpls MN 55344 Cable Specifications Cable Characteristics The physical characteristics of the 10BaseT cable must meet or exceed IEEE 802 3 10BaseT specifications 10BaseT Cable Specifications Either shielded or unshielded twisted pair ca...

Page 5: ...ket Hub Ethernet Pocket Hub n e t w o r k s T R A N S I T I O N Mpls MN 55344 n e t w o r k s T R A N S I T I O N Mpls MN 55344 n e t w o r k s T R A N S I T I O N Mpls MN 55344 n e t w o r k s T R A N S I T I O N Mpls MN 55344 n e t w o r k s T R A N S I T I O N Mpls MN 55344 Model 0403 Ethernet Pocket Hub Specifications Dimensions 4 80 X 2 77 X 0 95 122mm x 70mm x 24mm Environment Temperature 0 ...

Page 6: ...attempt to repair the 0403 Pocket Hub or power supply adapter unit Failure to observe this warning could result in personal injury or death from electrical shock NOTE Failure to observe the above warning will immediately void the warranty Fault Isolation If two network devices fail to communicate through the 0403 Pocket Hub consider the following Are the LEDs described in the previous section func...

Page 7: ... The site for the 0403 Ethernet Repeater Hub must provide AC power outlet for each Hub Adequate ventilation Standard environmental conditions Isolation from electrical noise including radio transmitters and broadband amplifiers motors high power electrical lines or fluorescent light fixtures Additionally The twisted pair cables should not run in the same conduit with power line cables Phone lines ...

Page 8: ...Hubs the transmission path between any two Data Terminating Equipment DTE terminals can consist of no more than five segments To assign segment numbers to cable connections 1 Determine the two terminals in the network which are separated by the greatest number of segments 2 Assign a segment path between the terminals by labeling the cable connected to one of the terminals segment 1 and the segment...

Page 9: ...10BaseT Ethernet Pocket Hub n e t w o r k s T R A N S I T I O N Mpls MN 55344 Straight through 10BaseT Crossover 10BaseT 2 Ethernet Pocket Hub n e t w o r k s T R A N S I T I O N Mpls MN 55344 Ensuring Correct 10BaseT Configuration The 10BaseT cable and RJ 45 jacks for Hub to Terminal connections must be configured as straight through The 10BaseT cable and RJ 45 jacks for Hub to Hub connections mu...

Page 10: ...h cable orientation or to Pocket Hub RJ 45 jack connector using crossover cable orientation NOTE Examples are provided in the pages that follow 3 INSTALLATION NOTE 0403 Ethernet Pocket Hub Link Integrity cannot be disabled All devices connected to the Pocket Hub MUST have link functions enabled To install the 0403 Ethernet Pocket Hub Unpack the 0403 Pocket Hub Connect 10Base2 Cable to the 0403 Poc...

Reviews: