Manual- Weighblok Rev 1 4-2-03
5
975 Deerfield Parkway
800-503-9180
Buffalo Grove, IL 60089
847-419-1515
PARAMETER
DESCRIPTION
CODE/VALUE
F1
Graduations
Specifies number of the Weighingblocks graduations. Value should be consistent
with legal requirements and environmental limits on the useful system resolution.
500 1,000 1,500 2,000 2,500 3,000
4,000, 5,000 6,000 8,000 10,000
12,000 13,000 15,000 20,000 30,000
40,000 50,000
F2
Span Gain
Span Gain is related to A/D integration time. The larger the span gain, the higher the
internal resolution, but the slower the update speed.
25 50 75 100 150 200
F3
Zero Track Band
Selects the range within which the scale will automatically zero. Note that the scale
must be in standstill to automatically zero. Selections are in Display Divisions.
“
d
”
= graduation
0d 0.5d 1d 3d 5d
F4
Zero Range
Selects the range within which the scale may be zeroed. Note that the indicator must
be in standstill to zero the scale.
100%
1.9%
2%
F5
Motion Band
Sets the level at which motion is detected by comparing the present display update
with the previous one. If motion is not detected for two seconds or more, scale is in
standstill and can process a Print or Zero command. Maximum value varies
depending on local regulations.
0.25
1d
3d
5d
10d
F6
Digital Filter
Averages weight readings to produce higher accuracy. The higher the filter number,
the greater the accuracy but the slower the response time. Choose 4 or 8 unless a very
fast response is needed.
1
2
4
8
F7
Overload Limit
Selects the desired formula which determines the point at which the indicator shows
overload ("
oooo
"). All selections are based on the primary unit selected in F8.
"FS" = Full scale in primary units.
FS
FS + 2%
FS + 1d
FS + 9d
F8
Calib. Unit
Selects the primary base unit to be used in the calibration process. Also the default
unit for normal operation.
"1"
=
primary unit is lb.
"2" = primary unit is in kg.
1
2
F9
Display Div.
Determines the desired weight increments. Value should be consistent with legal
requirements.
1
2
5
F10
Decimal Pt.
Determines location of the decimal point.
0
0.0
0.00
0.000
0.0000
F11
Batching function.
Activating Batching function (not be used with
“
EC
”
-Scales
0 = OFF
1 = ON
F16
Zero Calibration
Places indicator into the zero calibration routine. Scrolling down with the ZERO key
one level begins the procedure.
Press ZERO key to begin sequence
F17
Span Calibration
Places indicator into the span calibration routine. Scrolling down with the ZERO key
one level begins the procedure.
Press ZERO key to begin sequence
F18
F19
F20
F21
Factory Reset
This sub-menu will reset all parameters in the
“
F
”
and
“
A
”
menu to the default
settings. USE WITH CAUTION!
Press the ZERO key twice to execute.
A1
A2
A3
A4
A5
Disable the lb/kg
Key
Allows the lb/kg key to be disabled and allows use of extended graduation.
"0" = Disable the lb/kg key
"1" = Enable the lb/kg key
”
2
”
Activate the extended graduation for VB2-100-EC
0
1
2