background image

 

 

© Adam Equipment Company 2012

 

 

Adam Equipment 

 

 

SHS SERIES 

 

(P.N. 7.00.6.6.0202, Revision A1 March 2012) 

Summary of Contents for SHS 150

Page 1: ... Adam Equipment Company 2012 Adam Equipment SHS SERIES P N 7 00 6 6 0202 Revision A1 March 2012 ...

Page 2: ...IFICATIONS 3 2 3 SAFETY NOTICE 4 2 4 KEY AND PANEL DESCRIPTION 5 2 5 DISPLAY INDICATIONS WITH LED 5 3 0 OPERATION 6 3 1 SAFETY INSTRUCTIONS 6 3 2 BATTERY OPERATION 7 3 3 BASIC OPERATIONS 8 3 4 REMOTE CONTROL UNIT 9 3 5 USER PARAMETERS 9 4 0 CALIBRATION 10 5 0 PARTS LIST 11 WARRANTY INFORMATION 13 ...

Page 3: ... display enabling a good viewing angle 360 degree rotary safety hook and support ring design Overload safety up to 150 of model capacity Selectable weighing units include kg Lbs and Newtons Hold feature Internal lithium battery fitted as standard Alternative power from AA or NiMH batteries Auto power off after 30 minutes of non use 8 4Vdc 800ma battery charger Strong ABS plastic housing Infrared r...

Page 4: ...3 Adam Equipment Company 2012 2 2 TECHNICAL SPECIFICATIONS Model No Capacity Division SHS 50 50kg 0 01kg SHS 150 150kg 0 02kg SHS 300 300kg 0 05kg ...

Page 5: ...nisations cannot be held liable for any resulting damage or injury sustained as a result of the machines being used in excess of their stated capacities or ultimate overload limits Model No SHS 50 SHS 150 SHS 300 Max capacity 50kg 150kg 300kg Overload capacity 100kg 300kg 450kg NOTICE Do not use the scales if any parts are bent or loose or show signs of damage or wear Refer to the user manual ...

Page 6: ...e UNIT key to change the weighing unit being displayed Kg Lbs and Newtons are available HOLD Use this key to hold the display When pressed an LED will light at the top left side of the display and the reading on the display will lock and flash Press the HOLD key again to cancel the HOLD function 2 5 DISPLAY INDICATIONS WITH LED Kg lb N Weighing unit Indicator Low battery Indicator Hold Hold Indica...

Page 7: ...n for any damage or wear and tear on parts The split pins in particular at the hook and eyebolts as well as the inner wall of the hook and all joints should be checked regularly If any damage or wear has taken place stop using the scale and replace the parts Do all inspection and maintenance work when the scale is not in use Do not expose the scale to extreme temperatures The operating temperature...

Page 8: ...ower supply and wait until the LED on the charger shows green The battery is now fully charged Charging time for a completely discharged battery is approximately 16 hours A full battery pack is recommended to keep the scale continuously operational Only use the charger as supplied with the unit The switch inside the battery cover must be in position A to make use of the lithium battery If using AA...

Page 9: ...Hold When the reading may not be perfectly stable or you cannot view a reading easily you can press the HOLD key to lock it The reading will be locked and also flash at the point you press the HOLD button enabling you to view it when you can Once you have noted the reading press HOLD again to return to normal weighing mode Overload Warning Please do not add any item that exceeds the maximum capaci...

Page 10: ...ble parameters are available on the SHS to access these power up the scale and whilst the display is counting down press and then release the UNIT button The display should show Bee 0 which is the first of the parameters Press the HOLD button to change the setting and the ZERO button to move to the next setting Parameter setting table FUNCTION DESCRIPTION DEFAULT BEE Sets buzzer 0 Disable 1 Enable...

Page 11: ...stable This completes the zero calibration Following zero calibration the value of the mass being used to calibrate the scale should be entered Use the HOLD button to increment the right hand digit and the UNIT button to move this digit to the left Proceed by entering a number for the next digit if required until the value of your chosen calibration weight is displayed correctly Load this mass ont...

Page 12: ... PCB 9 7 00 1 0 0280 SHS LOAD CELL 50kg 10 7 00 1 0 0281 SHS LOAD CELL 150kg 10 7 00 1 0 0282 SHS LOAD CELL 300kg 10 7 00 5 6 0048 SHS KEYPAD PANEL 11 7 00 1 0 0283 SHS HOOK 12 7 00 5 6 0049 SHS DISPLAY PANEL 50kg 13 7 00 5 6 0050 SHS DISPLAY PANEL 150kg 13 7 00 5 6 0051 SHS DISPLAY PANEL 300kg 13 7 00 4 0 0094 SHS KEYBOARD PUSHBUTTON 7 00 4 0 0096 SHS 8 4 VDC 800ma UK CHARGER UNIT 7 00 4 0 0097 S...

Page 13: ...12 Adam Equipment Company 2012 ...

Page 14: ...l packaging and with correct documentation for a claim to be processed All claims are at the sole discretion of Adam Equipment This warranty does not cover equipment where defects or poor performance is due to misuse accidental damage exposure to radioactive or corrosive materials negligence faulty installation unauthorised modifications or attempted repair or failure to observe the requirements a...

Page 15: ...in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Shielded interconnect cables must be employed with this equipment to insure compliance with the pertinent RF emission limits governing this device Changes or modifications not expressly approved by Adam Equipment could void the user s authority to ope...

Page 16: ...Health and Fitness Scales Retail Scales for Price computing For a complete listing of all Adam products visit our website at www adamequipment com Copyright by Adam Equipment Co Ltd All rights reserved No part of this publication may be reprinted or translated in any form or by any means without the prior permission of Adam Equipment Adam Equipment reserves the right to make changes to the technol...