![Trane Voyager Commercial Installation, Operation And Maintenance Manual Download Page 33](http://html1.mh-extra.com/html/trane/voyager-commercial/voyager-commercial_installation-operation-and-maintenance-manual_1149066033.webp)
RT-SVX34R-EN
33
N
NO
OT
TIIC
CE
E
C
Co
om
mp
po
on
ne
en
ntt F
Fa
aiillu
urre
e!!
R
Re
essiisstta
an
ncce
e iin
n e
ex
xcce
essss o
off 3
3 o
oh
hm
mss p
pe
err cco
on
nd
du
ucctto
orr
cco
ou
ulld
d rre
essu
ulltt iin
n cco
om
mp
po
on
ne
en
ntt ffa
aiillu
urre
e d
du
ue
e tto
o
iin
nssu
uffffiicciie
en
ntt A
AC
C v
vo
olltta
ag
ge
e ssu
up
pp
plly
y..
D
Do
o n
no
ott e
ex
xcce
ee
ed
d tth
hrre
ee
e ((3
3)) o
oh
hm
mss p
pe
err cco
on
nd
du
ucctto
orr ffo
orr
tth
he
e lle
en
ng
gtth
h o
off tth
he
e rru
un
n..
Before installing any connecting wiring, refer to
for conductor sizing guidelines and;
•
Use copper conductors unless otherwise specified.
•
Ensure that the AC control voltage wiring between
the controls and the unit's termination point does
not exceed three (3) ohms/conductor for the length
of the run.
•
Refer to dimensional information beginning with
for the electrical access locations
provided on the unit.
•
Do not run the AC low voltage wiring in the same
conduit with the high voltage power supply wiring.
Be sure to check all loads and conductors for grounds,
shorts, and miswiring. After correcting any
discrepancies, reset the circuit breakers by pressing the
black button located on the left side of the transformer.
Table 15.
AC conductors size
Distance from unit to
control
Recommended wire
size
000-460 feet
18 gauge
461-732 feet
16 gauge
733-1000 feet
14 gauge
Field Installed DC Control Wiring
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss V
Vo
olltta
ag
ge
e!!
F
Fa
aiillu
urre
e tto
o d
diisscco
on
nn
ne
ecctt p
po
ow
we
err b
be
effo
orre
e sse
errv
viicciin
ng
g cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
D
Diisscco
on
nn
ne
ecctt a
allll e
elle
eccttrriicc p
po
ow
we
err,, iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e
d
diisscco
on
nn
ne
eccttss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err
llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e tth
he
e p
po
ow
we
err
cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. V
Ve
erriiffy
y tth
ha
att n
no
o
p
po
ow
we
err iiss p
prre
esse
en
ntt w
wiitth
h a
a v
vo
ollttm
me
ette
err..
W
WA
AR
RN
NIIN
NG
G
P
Prro
op
pe
err F
Fiie
elld
d W
Wiirriin
ng
g a
an
nd
d G
Grro
ou
un
nd
diin
ng
g
R
Re
eq
qu
uiirre
ed
d!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w cco
od
de
e cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr
sse
erriio
ou
uss iin
njju
urry
y..
A
Allll ffiie
elld
d w
wiirriin
ng
g M
MU
US
ST
T b
be
e p
pe
errffo
orrm
me
ed
d b
by
y q
qu
ua
alliiffiie
ed
d
p
pe
errsso
on
nn
ne
ell.. IIm
mp
prro
op
pe
errlly
y iin
nsstta
alllle
ed
d a
an
nd
d g
grro
ou
un
nd
de
ed
d
ffiie
elld
d w
wiirriin
ng
g p
po
osse
ess F
FIIR
RE
E a
an
nd
d E
EL
LE
EC
CT
TR
RO
OC
CU
UT
TIIO
ON
N
h
ha
azza
arrd
dss.. T
To
o a
av
vo
oiid
d tth
he
esse
e h
ha
azza
arrd
dss,, y
yo
ou
u M
MU
US
ST
T ffo
ollllo
ow
w
rre
eq
qu
uiirre
em
me
en
nttss ffo
orr ffiie
elld
d w
wiirriin
ng
g iin
nsstta
alllla
attiio
on
n a
an
nd
d
g
grro
ou
un
nd
diin
ng
g a
ass d
de
essccrriib
be
ed
d iin
n N
NE
EC
C a
an
nd
d y
yo
ou
urr llo
occa
all//
sstta
atte
e//n
na
attiio
on
na
all e
elle
eccttrriicca
all cco
od
de
ess..
N
NO
OT
TIIC
CE
E
U
Usse
e C
Co
op
pp
pe
err C
Co
on
nd
du
ucctto
orrss O
On
nlly
y!!
F
Fa
aiillu
urre
e tto
o u
usse
e cco
op
pp
pe
err cco
on
nd
du
ucctto
orrss cco
ou
ulld
d rre
essu
ulltt iin
n
e
eq
qu
uiip
pm
me
en
ntt d
da
am
ma
ag
ge
e a
ass tth
he
e e
eq
qu
uiip
pm
me
en
ntt w
wa
ass n
no
ott
d
de
essiig
gn
ne
ed
d o
orr q
qu
ua
alliiffiie
ed
d tto
o a
acccce
ep
ptt o
otth
he
err tty
yp
pe
ess o
off
cco
on
nd
du
ucctto
orrss..
Before installing the connecting wiring between the
components utilizing a DC analog output/input signal
and the unit, refer to
for conductor
sizing guidelines and;
•
Use standard copper conductor thermostat wire
unless otherwise specified.
•
Ensure that the wiring between the controls and the
unit's termination point does not exceed two and a
half (2-1/2) ohms/conductor for the length of the
run.
N
No
otte
e:: Resistance in excess of 21/2 ohms per
conductor can cause deviations in the
accuracy of the controls.
•
Refer to dimensional drawings beginning with
for the electrical access locations
provided on the unit.
•
Do not run the electrical wires transporting DC
signals in or around conduit housing high voltage
wires.
Table 16.
DC conductors
Distance from unit to
control
Recommended wire
size
000-150 feet
22 gauge
151-240 feet
20 gauge
241-385 feet
18 gauge
386-610 feet
16 gauge
611-970 feet
14 gauge
Units equipped with the Trane Communication
Interface (TCI) option, which utilizes a serial
communication link;
Summary of Contents for Voyager Commercial
Page 153: ...RT SVX34R EN 153 N No ot te es s...
Page 154: ...154 RT SVX34R EN N No ot te es s...
Page 155: ...RT SVX34R EN 155 N No ot te es s...