TEMPERATURE LOCK-OUT:

The digital thermostat in this pool heater allows the user to lock the maximum temperature setting allowed. 

This feature is useful for preventing unauthorized users from manually adjusting the temperature settings higher 
than desired. On a new heater, the maximum allowed temperature lock settings are initially set at the factory to 
90°F for POOL mode, and 104°F for SPA mode. To adjust these settings, use the following procedure:

1.  Use the MODE button to put the heater in STANDBY mode.
2.  Press and hold both the UP and DOWN buttons at the same time.
3.  After 3 seconds, the thermostat enters maximum temperature lock adjustment mode.
4.  The SPA indicator light illuminates and the numeric display shows the current SPA mode maximum 

 

temperature lock setting.  Both the SPA indicator light and the numeric display fl ashes rapidly when in  

 adjustment 

mode.

5.  Use the UP and DOWN buttons to set the desired maximum temperature lock setting. When fi nished,  

 

press the MODE button.

6.  The POOL indicator light illuminates and the numeric display shows the current POOL mode maximum  

 

temperature lock setting.  Both the POOL indicator light and the numeric display fl ashes rapidly when in  

 adjustment 

mode.

7.  Use the UP and DOWN buttons to set the desired maximum temperature lock. When fi nished, press the  

 MODE 

button.

8.  The heater will return to STANDBY mode.

FAHRENHEIT VERSUS CELSIUS:

The temperature can be displayed in Fahrenheit or Celsius. TO change the display, use the “MODE” button 

to place the heater in “STANDBY”. Then press and hold the “UP” and “MODE” buttons until the display shows 
the °F/°C selection. Press the “DOWN” button to toggle between selections. To accept the selection, press the 
“MODE” button. If the user does not act, the selection will be automatically accepted after 60 seconds.

WINTERIZATION:

In moderate climates, the heater can continue to operate during short-term cold spells. Do not use the 

heater to maintain the water temperature just above freezing or for freeze protection. Care must be taken to 
avoid freeze-up in the heater. When it is used during freezing weather, the pump must run continuously. The 
heater is not warranted against freeze-ups. In regions where freezing temperatures are encountered, all water 
must be drained from the heater when it is out of service, to prevent damage to the heater and piping. Drain-
ing the heat exchanger is recommended as part of the season’s shutdown procedures.

SPRING 

START-UP – CONSULT 

PROFESSIONAL:

1.  Inspect and clean the heater, being sure the heater is free of leaves and debris prior to startup.
2.  Be sure inlet and outlet piping are properly attached to the heater and the drain valve is closed.
3. Turn the fi ltration system pump “ON” and allow the system to run long enough to purge all the air 

from the lines.

4.  Turn the gas supply to the heater “ON”.
5.  Set the temperature control using the keypad to “POOL” or “SPA” and adjust the set point to the 

desired temperature setting.

6.  If operating diffi culties are encountered, contact a qualifi ed service company for assistance.

Summary of Contents for TR250

Page 1: ...re department Installation and service must be per formed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage injury or death Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance This prod...

Page 2: ...nsumer Operation Maintenance 8 Maintaining proper water chemistry 8 Lighting Operating instructions label 10 Temperature adjustment 11 Temperature Lock out 12 Fahrenheit versus Celsius 12 Winterization 12 Spring start up 12 Error codes 13 Warranty 15 CONTENTS ...

Page 3: ...o be used with spas Do NOT use with storable pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for outdoor use it is strongly recommended ...

Page 4: ...hrough an unprotected suction outlet sump or suction outlet cover which is damaged broken cracked missing or unsecured can result in evisceration disembowelment Mechanical Entrapment There is potential for jewelry swimsuit hair decorations finger toe or knuck le to be caught in an opening of a suction outlet or suction outlet cover resulting in mechanical entrap ment WARNING To reduce the risk of ...

Page 5: ...ing pool and spa water circulation system all system and pump controls must be in off position and filter manual air relief valve must be in open position Before starting system pump all system valves must be set in a position to allow system water to return back to the pool Do not change filter control valve position while system pump is running Before starting system pump fully open filter manua...

Page 6: ...h the advice of a physician Always stir pool spa water before entering the pool spa to mix in any hot surface layer of water that might exceed healthful temperature limits and cause injury Do not tamper with controls because scalding can result if safety controls are not in proper working order 7 Persons with a medical history of heart disease circulatory problems diabetes or blood pressure proble...

Page 7: ...the original purchaser repair or at our option replace without charge any defective part We further warrant that if the heat exchanger or exchanger headers water containing section leak within one year from date of such installation for all users due to defects in materials and workmanship we will provide a replacement part Cost of freight installation fuel and service labor after one year is at u...

Page 8: ... pool water changes daily due to the addition of pool and sanitizing chemicals bather loads rain runoff and the amount of sun to name a few Improper chem istry balance and mineral content can cause scaling and deposits to form on pool walls in the filtration system in the heat exchanger tubes and additionally can promote corrosive action to all metals in the water path Chang ing spa water regularl...

Page 9: ...tion requirements shown in the installation manual on page 26 5 BYPASS Until water chemistry is properly balanced and if your piping has a bypass valve installed for the heater open the bypass so that corrosive and potentially damaging water will not flow through the heater and there fore the heat exchanger Close the bypass valve once the water is properly balanced Failure to close the bypass valv...

Page 10: ...10 Figure 2 Lighting Operating Instructions label ...

Page 11: ...mperature setting is being displayed adjusted When the numeric display is not flashing the actual water temperature is being displayed The temperature settings for both SPA and POOL modes are initially set at the factory to 65 F The minimum allowed settings for SPA and POOL modes are both 65 F The maximum allowed settings for SPA and POOL modes are adjustable up to 104 F using the temperature lock...

Page 12: ...played in Fahrenheit or Celsius TO change the display use the MODE button to place the heater in STANDBY Then press and hold the UP and MODE buttons until the display shows the F C selection Press the DOWN button to toggle between selections To accept the selection press the MODE button If the user does not act the selection will be automatically accepted after 60 seconds WINTERIZATION In moderate...

Page 13: ...d control will run blower for 5 s then automatically restart after 2 minutes PF Electrical supply wiring error This code will display if 120V polarity is reversed low voltage is detected or if the ground path is not sufficient Reset is immediate after error is corrected AO Blower vacuum switch open error If the blower prover switch does not close after the blower starts the control will stop the i...

Page 14: ...ormal operation resumes when temperatures stabilize If this condi tion is detected 3 times in a one hour period the heater will lock out until the electrical power is cycled off and back on Sb Keypad button stuck closed error If one of the keypad buttons is closed or pressed for more than 30 s the error code will be displayed but the control will continue to function The error code will be cleared...

Page 15: ...ent installation and maintenance and adhering to the requirements of the jurisdic tion where the product is installed There are no warranties which extend beyond the description on the face hereof We shall not in any event be held liable for any special indirect or consequential damages EXPENSE OF DELIVERY AND INSTALLATION Each pool heater or replacement part to be furnished under this warranty sh...

Page 16: ... to state LIMITATION ON LIABILITY All intended representations have been expressly set forth in this document This warranty may not be extended by oral or any other additional representations written sales information drawings or other mal function is strictly limited to repair or replacement of the defective heater or part as provided herein and the manufacturer is not responsible hereunder for i...

Reviews: