TEMPERATURE ADJUSTMENT

This pool heater is equipped with a digital thermostat which allows the user to select the desired water 

temperature. The heater will then function automatically to maintain the desired temperature. The heater has 
3 modes of operation:

1.  STANDBY: in this mode, the heater will not function to heat the water.
2.  SPA: in this mode, the heater will automatically function to maintain the water temperature setting for  

 SPA 

mode.

3.  POOL: in this mode, the heater will automatically function to maintain the water temperature setting  

 

for POOL mode.

Use the MODE button to change modes. The indicator lights will illuminate to show which mode the 

heater is currently in. Each mode has its own temperature setting, allowing the user to have 2 individual 
pre-set temperature settings. To adjust the temperature while in SPA or POOL mode, use the UP and DOWN 
buttons. The numeric display will fl ash to indicate the temperature setting is being displayed / adjusted. When 
the numeric display is not fl ashing, the actual water temperature is being displayed. The temperature settings 
for both SPA and POOL modes are initially set at the factory to 65°F. The minimum allowed settings for SPA 
and POOL modes are both 65°F. The maximum allowed settings for SPA and POOL modes are adjustable up 
to 104°F using the temperature lockout feature (see next section).

After selecting SPA or POOL mode or adjusting the temperature setting, it is normal for the heater to 

delay up to 10 seconds before the heater starts operating. This delay is an internal self-test of the heater.  On 
occasion, the numeric display may show a diagnostic error code; refer to list of diagnostic error codes in 
Figure 4.  Pressing the MODE button to cycle to STANDBY and back to SPA or POOL will clear a diagnostic 
error code. When clearing a diagnostic error code this way, it is normal for the heater to delay up to 5 seconds 
before resuming normal operation, assuming the diagnostic error code does not re-appear.

Figure 3: User interface keypad

Numeric Display

Buttons

Indicator Lights

Summary of Contents for TR250

Page 1: ...re department Installation and service must be per formed by a qualified installer service agency or the gas supplier FOR YOUR SAFETY WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage injury or death Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance This prod...

Page 2: ...nsumer Operation Maintenance 8 Maintaining proper water chemistry 8 Lighting Operating instructions label 10 Temperature adjustment 11 Temperature Lock out 12 Fahrenheit versus Celsius 12 Winterization 12 Spring start up 12 Error codes 13 Warranty 15 CONTENTS ...

Page 3: ...o be used with spas Do NOT use with storable pools A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Though this product is designed for outdoor use it is strongly recommended ...

Page 4: ...hrough an unprotected suction outlet sump or suction outlet cover which is damaged broken cracked missing or unsecured can result in evisceration disembowelment Mechanical Entrapment There is potential for jewelry swimsuit hair decorations finger toe or knuck le to be caught in an opening of a suction outlet or suction outlet cover resulting in mechanical entrap ment WARNING To reduce the risk of ...

Page 5: ...ing pool and spa water circulation system all system and pump controls must be in off position and filter manual air relief valve must be in open position Before starting system pump all system valves must be set in a position to allow system water to return back to the pool Do not change filter control valve position while system pump is running Before starting system pump fully open filter manua...

Page 6: ...h the advice of a physician Always stir pool spa water before entering the pool spa to mix in any hot surface layer of water that might exceed healthful temperature limits and cause injury Do not tamper with controls because scalding can result if safety controls are not in proper working order 7 Persons with a medical history of heart disease circulatory problems diabetes or blood pressure proble...

Page 7: ...the original purchaser repair or at our option replace without charge any defective part We further warrant that if the heat exchanger or exchanger headers water containing section leak within one year from date of such installation for all users due to defects in materials and workmanship we will provide a replacement part Cost of freight installation fuel and service labor after one year is at u...

Page 8: ... pool water changes daily due to the addition of pool and sanitizing chemicals bather loads rain runoff and the amount of sun to name a few Improper chem istry balance and mineral content can cause scaling and deposits to form on pool walls in the filtration system in the heat exchanger tubes and additionally can promote corrosive action to all metals in the water path Chang ing spa water regularl...

Page 9: ...tion requirements shown in the installation manual on page 26 5 BYPASS Until water chemistry is properly balanced and if your piping has a bypass valve installed for the heater open the bypass so that corrosive and potentially damaging water will not flow through the heater and there fore the heat exchanger Close the bypass valve once the water is properly balanced Failure to close the bypass valv...

Page 10: ...10 Figure 2 Lighting Operating Instructions label ...

Page 11: ...mperature setting is being displayed adjusted When the numeric display is not flashing the actual water temperature is being displayed The temperature settings for both SPA and POOL modes are initially set at the factory to 65 F The minimum allowed settings for SPA and POOL modes are both 65 F The maximum allowed settings for SPA and POOL modes are adjustable up to 104 F using the temperature lock...

Page 12: ...played in Fahrenheit or Celsius TO change the display use the MODE button to place the heater in STANDBY Then press and hold the UP and MODE buttons until the display shows the F C selection Press the DOWN button to toggle between selections To accept the selection press the MODE button If the user does not act the selection will be automatically accepted after 60 seconds WINTERIZATION In moderate...

Page 13: ...d control will run blower for 5 s then automatically restart after 2 minutes PF Electrical supply wiring error This code will display if 120V polarity is reversed low voltage is detected or if the ground path is not sufficient Reset is immediate after error is corrected AO Blower vacuum switch open error If the blower prover switch does not close after the blower starts the control will stop the i...

Page 14: ...ormal operation resumes when temperatures stabilize If this condi tion is detected 3 times in a one hour period the heater will lock out until the electrical power is cycled off and back on Sb Keypad button stuck closed error If one of the keypad buttons is closed or pressed for more than 30 s the error code will be displayed but the control will continue to function The error code will be cleared...

Page 15: ...ent installation and maintenance and adhering to the requirements of the jurisdic tion where the product is installed There are no warranties which extend beyond the description on the face hereof We shall not in any event be held liable for any special indirect or consequential damages EXPENSE OF DELIVERY AND INSTALLATION Each pool heater or replacement part to be furnished under this warranty sh...

Page 16: ... to state LIMITATION ON LIABILITY All intended representations have been expressly set forth in this document This warranty may not be extended by oral or any other additional representations written sales information drawings or other mal function is strictly limited to repair or replacement of the defective heater or part as provided herein and the manufacturer is not responsible hereunder for i...

Reviews: