11
UNT-PRC002-GB
Sound power levels
Discharge
Measurement conditions:
Measurements taken in a room adjacent to the room containing the FWD, at the outlet of the rectangular duct (1.5 m
long) fixed to its discharge opening.
Fan
Power level in dB(A), per Hz frequency band
Overall power
Unit
speed
125
250
500
1000
2000
4000
8000
dB(A)
1
55
50
42
37
37
31
30
46
FWD 08
2
57
54
47
40
30
38
40
50
3
58
57
50
42
32
40
43
53
1
57
51
45
42
34
33
28
48
FWD 10
2
58
54
48
45
38
39
35
51
3
60
58
50
48
40
42
39
54
1
57
51
45
42
34
33
28
48
FWD 12
2
58
54
48
45
38
39
35
51
3
60
58
50
48
40
42
39
54
1
56
62
50
48
39
38
36
56
FWD 14
2
61
66
55
53
47
46
45
60
3
63
69
58
56
50
50
49
63
1
57
63
51
49
40
39
37
57
FWD 20
2
61
66
55
53
47
46
45
60
3
63
69
58
56
50
50
49
63
Intake
Measurement conditions:
Measurements taken at the horizontal air intake.
Fan
Power level in dB(A), per Hz frequency band
Overall power
Unit
speed
125
250
500
1000
2000
4000
8000
dB(A)
1
56
55
55
53
46
45
42
57
FWD 08
2
63
62
60
60
53
53
53
64
3
66
65
63
62
56
55
57
67
1
62
58
55
58
51
48
44
61
FWD 10
2
66
63
60
62
56
55
52
66
3
70
67
63
65
59
59
57
69
1
62
58
55
58
51
48
44
61
FWD 12
2
66
63
60
62
56
55
52
66
3
70
67
63
65
59
59
57
69
1
66
65
65
65
57
50
46
68
FWD 14
2
73
72
69
71
64
59
57
74
3
78
76
73
75
69
64
63
78
1
68
72
64
64
56
52
50
69
FWD 20
2
76
76
68
71
65
61
61
75
3
78
79
71
74
69
66
66
78
CG-SVX051A-GB
11
Table 1 - General data CMAF 080-100 Standard Short Efficiency
Unit size
080
090
100
Total cooling capacity (1)
kW
269
301
327
Total heating capacity (1)
kW
290
323
353
Total power Input (1)
kW
91
106
121
Unit Electrical Data (2) (3) (4)
Short Circuit Unit Capacity (9)
kA
15
15
15
Power Cable Cross Section (max)
mm²
1*240
1*240
1*240
Disconnect switch size
A
400
400
500
Digit 56=1 AC fan
Max. power input
kW
119
138
157
Max. Amps
A
205
237
270
Unit start up amps (w/o soft starter - Digit 54=A) (4)
A
419
495
527
Unit start up amps (with soft starter - Digit 54=B) (4)
A
315
367
399
Displacement power factor (dpf)
-
0.83
0.84
0.84
Digit 56=2 EC fan
Max. power input
kW
N/A
N/A
N/A
Max. Amps
A
N/A
N/A
N/A
Unit start up amps (w/o soft starter - Digit 54=A) (4)
A
N/A
N/A
N/A
Unit start up amps (with soft starter - Digit 54=B) (4)
A
N/A
N/A
N/A
Displacement power factor (dpf)
-
N/A
N/A
N/A
Digit 56=3 EC fan HESP
Max. power input
kW
N/A
N/A
N/A
Max. Amps
A
N/A
N/A
N/A
Unit start up amps (w/o soft starter - Digit 54=A) (4)
A
N/A
N/A
N/A
Unit start up amps (with soft starter - Digit 54=B) (4)
A
N/A
N/A
N/A
Displacement power factor (dpf)
-
N/A
N/A
N/A
Compressors
Manifold Tonnage (Ton) Circuit 1 and 2
25+25
25+30
30+30
Max Comp Power input Circuit 1 / Circuit 2
kW
56.9/56.9
66.7/66.7
76.5/76.5
Rated Amps Circuit 1 / Circuit 2 (4)
A
93/93
109/109
76.5/76.5
Start Amps Circuit 1 / Circuit 2 (Digit 54=A) (4)
A
307/307
367/367
125/125
Start Amps Circuit 1 / Circuit 2 (Digit 54=B) (4)
A
203/203
239/239
383/383
Locked Rotor Amps Circuit 1 / Circuit 2 (4)
A
260+260/
260+260
260+320/
260+320
320+320/
320+320
Motor speed
rpm
2900
2900
2900
Oil sump heater Circuit 1 / Circuit 2
W
180/180
180/180
180/180
Number or refrigerant circuits
-
2
2
2
Number of part load steps
-
4
8
4
Minimum capacity step
%
25
23
25
Dual Circuit Chilled Water Exchanger
Brazed Plate Heat Exchanger Materials (model)
-
Stainless Steel / Copper (DFX 650)
Plate number
-
106
138
138
Water Content
l
31
40.4
40.4
Nominal water connection size
in
4
4
4
(Grooved coupling) - With or without HYM
mm
114.3
114.3
114.3
Water Pressure Drop (1)
kPa
46.8
35.7
41.5
Dual Circuit Hot Water exchanger
Brazed Plate Heat Exchanger Materials (model)
-
Stainless Steel / Copper (DFX 650)
Plate number
-
138
166
166
Water Content
l
40.4
48.6
48.6
Nominal water connection size
in
4
4
4
(Grooved coupling) - With or without HYM
mm
114.3
114.3
114.3
Water Pressure Drop (1)
kPa
39.3
34.3
40.3
Condenser Module
Coils
Type
-
Aluminum / Copper Fin and Tube
Total Quantity
-
6
6
6
Face area per circuit
m²
7
7
7
Fans
Type
-
Propeller Fan: Fixed speed AC motor
Number of fans
-
6
6
6
Air flow (1), cooling mode
m3/h
114,617
114,169
113,776
Air flow (2), heating/heat pump mode
m3/h
113,907
114,062
114,188
Digit 56=1 AC fan
Max Power Input per Motor
kW
1.4
1.4
1.4
Max Amps per Motor
A
2.8
2.8
2.8
Motor RPM (Cooling mode)
rpm/min
870
870
870
Digit 56=2 EC fan
Max Power Input per Motor
kW
N/A
N/A
N/A
Max Amps per Motor
A
N/A
N/A
N/A
Motor RPM (Cooling mode)
rpm/min
N/A
N/A
N/A
Digit 56=3 EC fan HESP
Max Power Input per Motor
kW
N/A
N/A
N/A
Max Amps per Motor
A
N/A
N/A
N/A
Motor RPM (Cooling mode field setting)
rpm/min
N/A
N/A
N/A
General Data