SSP-SVX001B-EN
25
Unit Power Supply
The installer must provide line voltage circuit(s) to the
unit main power terminals as shown by the unit wiring
diagrams. Adhesive backed diagrams are affixed inside
the control box cover panel. Wiring diagrams are also
available through e-Library or by contacting a local
sales office. Power supply must include a disconnect
switch in a location convenient to the unit. Ground the
unit according to local codes and provide flexible
conduit if codes require and/or if vibration transmission
may cause noise problems.
IIm
mp
po
orrtta
an
ntt:: All wiring must comply with applicable
local and national (NEC) codes. Type and
location of disconnect switches must
comply with all applicable codes.
W
WA
AR
RN
NIIN
NG
G
P
Prro
op
pe
err F
Fiie
elld
d W
Wiirriin
ng
g a
an
nd
d G
Grro
ou
un
nd
diin
ng
g
R
Re
eq
qu
uiirre
ed
d!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w cco
od
de
e cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr
sse
erriio
ou
uss iin
njju
urry
y..
A
Allll ffiie
elld
d w
wiirriin
ng
g M
MU
US
ST
T b
be
e p
pe
errffo
orrm
me
ed
d b
by
y q
qu
ua
alliiffiie
ed
d
p
pe
errsso
on
nn
ne
ell.. IIm
mp
prro
op
pe
errlly
y iin
nsstta
alllle
ed
d a
an
nd
d g
grro
ou
un
nd
de
ed
d
ffiie
elld
d w
wiirriin
ng
g p
po
osse
ess F
FIIR
RE
E a
an
nd
d E
EL
LE
EC
CT
TR
RO
OC
CU
UT
TIIO
ON
N
h
ha
azza
arrd
dss.. T
To
o a
av
vo
oiid
d tth
he
esse
e h
ha
azza
arrd
dss,, y
yo
ou
u M
MU
US
ST
T ffo
ollllo
ow
w
rre
eq
qu
uiirre
em
me
en
nttss ffo
orr ffiie
elld
d w
wiirriin
ng
g iin
nsstta
alllla
attiio
on
n a
an
nd
d
g
grro
ou
un
nd
diin
ng
g a
ass d
de
essccrriib
be
ed
d iin
n N
NE
EC
C a
an
nd
d y
yo
ou
urr llo
occa
all//
sstta
atte
e//n
na
attiio
on
na
all e
elle
eccttrriicca
all cco
od
de
ess..
N
NO
OT
TIIC
CE
E
U
Usse
e C
Co
op
pp
pe
err C
Co
on
nd
du
ucctto
orrss O
On
nlly
y!!
F
Fa
aiillu
urre
e tto
o u
usse
e cco
op
pp
pe
err cco
on
nd
du
ucctto
orrss cco
ou
ulld
d rre
essu
ulltt iin
n
e
eq
qu
uiip
pm
me
en
ntt d
da
am
ma
ag
ge
e a
ass tth
he
e e
eq
qu
uiip
pm
me
en
ntt w
wa
ass n
no
ott
d
de
essiig
gn
ne
ed
d o
orr q
qu
ua
alliiffiie
ed
d tto
o a
acccce
ep
ptt o
otth
he
err tty
yp
pe
ess o
off
cco
on
nd
du
ucctto
orrss..
Low Voltage Wiring
Mount the indoor thermostat, zone sensor, or
programmable zone sensor in accordance with the
corresponding thermostat installation instructions.
Install color-coded, weather-proof, multi-wire cable
according to the field wiring instructions (see
).
N
No
otte
e:: Refer to thermostat or zone sensor wire
installation guide for proper wire gauge.
Symbio
™
™
Controls
Wiring shown with dashed lines is to be furnished and
installed by the customer. All customer supplied wiring
must be copper only and must conform to NEC and
local electrical codes. Codes may require line of sight
between disconnect switch and unit.
Figure 14.
Symbio
™
™
jobsite connections
Zone Sensor
See Note 2
T’stat
See Note 2
Air Handler
Disconnect Switch
(By Others)
Disconnect Switch
(By Others)
See Note 1
Electric
Heat Accessory
Disconnect Switch
(By Others)
See Note 1
B
A
B
D
E
C
P
Po
ow
we
err W
Wiirre
ess
A. 3 wires, line voltage for 3 phase, (2 wires for single
phase) 1 grounding wire
B. 3 wires, line voltage for 3 phase, (2 wires for single
phase) 1 grounding wire
C
Co
on
nttrro
oll W
Wiirre
ess
C. Heat Pump thermostat: 6 to 9 wires depending on
T’stat options and stages of cooling and heating
D. Wiring between indoor and outdoor unit: 5 to 11
wires depending on unit control options*
E. Zone Sensor: 4 to 7 wires depending on zone sensor
model*
*Communication signal wires require twisted pairs.
Refer to unit schematics for identification of twisted
pairs.
N
No
otte
ess::
1. When electric heater accessory is used,
single point power entry or dual point power
entry is field optional. Single point power
entry option is through electric heater only.
2. ***Choose only one of the following;
Thermostat, Mechanical Zone Sensor,
Programmable Zone Sensor Panel or BAS
Zone Sensor.
IIm
mp
po
orrtta
an
ntt:: For the EDC switch to be functional and
thereby facilitate reliable unit operation,
make the EDC connections from the indoor
to the outdoor control boxes.