MUA-SVX005B-EN
7
General Safety Requirements
W
WA
AR
RN
NIIN
NG
G
H
Ha
azza
arrd
do
ou
uss S
Se
errv
viicce
e P
Prro
occe
ed
du
urre
ess!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w a
allll p
prre
ecca
au
uttiio
on
nss iin
n tth
hiiss m
ma
an
nu
ua
all a
an
nd
d o
on
n tth
he
e tta
ag
gss,, ssttiicckke
errss,, a
an
nd
d lla
ab
be
ellss cco
ou
ulld
d
rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
T
Te
ecch
hn
niicciia
an
nss,, iin
n o
orrd
de
err tto
o p
prro
otte
ecctt tth
he
em
msse
ellv
ve
ess ffrro
om
m p
po
otte
en
nttiia
all e
elle
eccttrriicca
all,, m
me
ecch
ha
an
niicca
all,, a
an
nd
d
cch
he
em
miicca
all h
ha
azza
arrd
dss,, M
MU
US
ST
T ffo
ollllo
ow
w p
prre
ecca
au
uttiio
on
nss iin
n tth
hiiss m
ma
an
nu
ua
all a
an
nd
d o
on
n tth
he
e tta
ag
gss,, ssttiicckke
errss,, a
an
nd
d
lla
ab
be
ellss,, a
ass w
we
ellll a
ass tth
he
e ffo
ollllo
ow
wiin
ng
g iin
nssttrru
uccttiio
on
nss:: U
Un
nlle
essss ssp
pe
ecciiffiie
ed
d o
otth
he
errw
wiisse
e,, d
diisscco
on
nn
ne
ecctt a
allll
e
elle
eccttrriicca
all p
po
ow
we
err iin
nccllu
ud
diin
ng
g rre
em
mo
otte
e d
diisscco
on
nn
ne
ecctt a
an
nd
d d
diisscch
ha
arrg
ge
e a
allll e
en
ne
errg
gy
y sstto
orriin
ng
g d
de
ev
viicce
ess
ssu
ucch
h a
ass cca
ap
pa
acciitto
orrss b
be
effo
orre
e sse
errv
viicciin
ng
g.. F
Fo
ollllo
ow
w p
prro
op
pe
err llo
occkko
ou
utt//tta
ag
go
ou
utt p
prro
occe
ed
du
urre
ess tto
o e
en
nssu
urre
e
tth
he
e p
po
ow
we
err cca
an
n n
no
ott b
be
e iin
na
ad
dv
ve
errtte
en
nttlly
y e
en
ne
errg
giizze
ed
d.. W
Wh
he
en
n n
ne
ecce
essssa
arry
y tto
o w
wo
orrkk w
wiitth
h lliiv
ve
e e
elle
eccttrriicca
all
cco
om
mp
po
on
ne
en
nttss,, h
ha
av
ve
e a
a q
qu
ua
alliiffiie
ed
d lliicce
en
nsse
ed
d e
elle
eccttrriicciia
an
n o
orr o
otth
he
err iin
nd
diiv
viid
du
ua
all w
wh
ho
o h
ha
ass b
be
ee
en
n
ttrra
aiin
ne
ed
d iin
n h
ha
an
nd
dlliin
ng
g lliiv
ve
e e
elle
eccttrriicca
all cco
om
mp
po
on
ne
en
nttss p
pe
errffo
orrm
m tth
he
esse
e tta
asskkss..
•
The use or storage of gasoline or other flammable vapors or liquids in open containers in the
vicinity of this appliance is hazardous.
•
If you smell gas:
–
Do not touch electrical switches.
–
Extinguish any open flames.
–
Immediately call your gas supplier.
•
Open all disconnect switches before installing the unit. If the power disconnect is out of sight,
lock it in the open position and tag it to prevent unexpected application of power. Failure to
do so may result in personal injury or death from electrical shock.
•
Failure to comply with the general requirements may result in extensive property damage,
severe personal injury or death.
•
Never service any component without first disconnecting all electrical and gas supplies to the
unit or severe personal injury or death may occur.
•
Do not alter the duct furnace in any way or damage to the unit, severe personal injury or
death will occur.
•
Do not attempt to convert the heater for use with a fuel other than the one intended. Such
conversion is dangerous, as it could create unsafe conditions that result in death, serious
injury or substantial property damage.
•
Do not depend upon a thermostat or other switch as the sole means of disconnecting power
when installing or servicing heater. Always disconnect power at main circuit breaker as
described above. Failure to do so could result in fatal electric shock.
1. Installation must be made in accordance with local codes, or in absence of local codes, with
ANSI Standard Z223.1-1996 (N.F.P.A. No 54) “National Fuel Gas Code”, or the latest edition
of. All ANSI and NFPA Standards referred to in these installation instructions are the ones
that were applicable at the time the design of this appliance was certified. The ANSI
Standards are available from the American Gas Association, 1515 Wilson Boulevard,
Arlington, Virginia 22209. The NFPA Standards are available from the National Fire Protection
Association, Batterymarch Park, Quincy, Massachusetts 02269. The heaters are designed for
use in airplane hangers when installed in accordance with ANSI/NFPA No. 409 and in public
garages when installed in accordance with the NFPA No. 88A and NFPA No. 88B.
2. If installed in Canada, the installation must conform with local building codes, or in the
absence of local building codes, with the current CGA-B149.1 or B149.2 “Installation Codes
for Gas Burning Appliances and Equipment”. These indoor duct furnaces have been designed
for and certified to comply with CGA 2.6.
3. No alterations are to be made on this equipment.
The duct furnace section of these make-up air units are certified by the American Gas Association
for use with natural and LP (propane) gases!
4. Make certain that the power sources conform to the requirements of the heater.
Summary of Contents for GGAA
Page 35: ...MUA SVX005B EN 35 Figure 12 Blower RPM Adjustment M Ma ai in nt te en na an nc ce e ...
Page 47: ...MUA SVX005B EN 47 Motor Electric Data Table 7 Full Load Current in Amperes ...
Page 50: ...50 MUA SVX005B EN Coil Cabinet Dimensional Data Figure 13 Coil Cabinet Dimensional Data ...
Page 57: ...MUA SVX005B EN 57 Gas Equipment Start Up ...
Page 58: ...58 MUA SVX005B EN N No ot te es s ...