background image

 

 

User Manual for your Classique 

 

600mm Stainless Steel Canopy Rangehood 

 
 

CLRH60LSS and CLRH60LW 

 

 

 
 

NOTE: This user manual contains important information including safety & 

installation points which will enable you to get the most out of your Classique 

appliance.  Please keep it in a safe place so that it is readily available for future 

reference. 

 
 

 

Summary of Contents for CLRH60LSS

Page 1: ...d CLRH60LSS and CLRH60LW NOTE This user manual contains important information including safety installation points which will enable you to get the most out of your Classique appliance Please keep it...

Page 2: ...grease filter 7 Maintenance Removing and cleaning the grease filter 8 Changing a light bulb 8 Fitting the carbon filter 9 Installation Electrical connection 10 Before beginning installation 11 Instal...

Page 3: ...ise be caused by inappropriate waste handling of this product The symbol on the product or on the documents accompanying the product indicates that this appliance may not be treated as household waste...

Page 4: ...gas appliance then the provision for ventilation must be in accordance with the Gas Installations standard AS NZS 5601 1 2 2013 the Gas Safety and Measurement Regulations 2010 and the Building Specif...

Page 5: ...e ducting for the extractor function has the same diameter as the outlet hole all the way through o Keep young children from using playing with or tampering with the rangehood o Your rangehood is for...

Page 6: ...rom a gas burner or heat from electric hob zones without a pan on them o Do not attempt to use the rangehood if it is damaged in any way Never attempt to use it without the grease filters fitted or if...

Page 7: ...hed stainless steel finish o 2 aluminium filters o 54dB noise level o Easy bracket installation o 150mm diameter ducting outlet o Extendable chimney flue Extraction capacity 550m hr Optional extras Re...

Page 8: ...idues from the manufacturing process To use your rangehood o A ON OFF button o B Speed selection buttons Low speed Medium speed High speed o C Light on off button o Before operating the hood make sure...

Page 9: ...ents and a new damp cloth o If you are using the appliance in recirculation mode then be sure to replace the carbon filters at the recommended interval see section on Fitting the carbon filter on page...

Page 10: ...to use your rangehood without the grease filter in place Changing a light bulb Part number SYKL10 LED LIGHT o IMPORTANT Always ensure the rangehood has been switched off before carrying out any work i...

Page 11: ...odours caused by cooking IMPORTANT Before attempting to fit or remove the carbon filters you must ensure the rangehood is switched off first 1 Press the handle of the metal grease filter towards the...

Page 12: ...power cable must be fitted upstream from the electrical connection using an omni polar switch with a contact distance of at least 3mm WARNING THIS APPLIANCE MUST BE EARTHED We recommend that the appl...

Page 13: ...ilters should be removed o Check inside the product and ensure that there is no transit packaging or any other materials such as packets of screws guarantees etc These should be removed and kept for f...

Page 14: ...talled o IMPORTANT If the recirculation vents are obstructed then the efficiency of the extraction will be affected and could damage the motor IMPORTANT YOUR RANGEHOOD SHOULD BE CONNECTED TO YOUR MAIN...

Page 15: ...ure the unit with two safety screws through the 6mm holes in the back casing Fitting the chimney 9 Take the two chimney sections C and D o Rest the bottom of chimney section C on the top of the hood Y...

Page 16: ...ney section D 11 Take the flat bracket E and place it between the two pencil marks that you made in step 9 o Keeping the bracket in contact with the wall use a pencil to mark on the wall the anchoring...

Page 17: ...mney section C Then secure the L shaped bracket to the wall using the same method as you have just used to secure the lower bracket 13 Lift chimney section D up to the ceiling and secure it to the L s...

Page 18: ...the other end of the ducting hose to the coupling in the top of the cooker hood Completing the installation If you are setting the appliance to recirculation mode then you should now fit the two carbo...

Page 19: ...ther to use it in extraction mode or recirculation mode What is the difference between extraction and recirculation modes In extraction mode the stale air will be taken via the grease filter and out o...

Page 20: ...outside wall this may not be possible The only alternative is to recirculate the air Do I need a charcoal filter All rangehoods have a grease filter but if you are using your rangehood in recirculatio...

Page 21: ...he rangehood is set up for recirculation mode check that the carbon filter does not need to be replaced o If the rangehood is set up for extraction mode check that the ducting hose and discharge outle...

Page 22: ...cessible for the Technician to perform any necessary repair If your appliance is installed in such a way that an engineer is concerned that damage will be caused to the appliance or your kitchen then...

Page 23: ......

Page 24: ...Imported by Applico Ltd Private Bag 92900 Onehunga Auckland 1061 New Zealand Website www classique co nz Phone 0800 M10 HLP or 0800 610 457...