MUA-SVX005B-EN
17
W
WA
AR
RN
NIIN
NG
G
F
Fiirre
e H
Ha
azza
arrd
d!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w iin
nssttrru
uccttiio
on
nss b
be
ello
ow
w cco
ou
ulld
d rre
essu
ulltt iin
n d
da
am
ma
ag
ge
e tto
o tth
he
e u
un
niitt g
ga
ass v
va
allv
ve
e a
an
nd
d
cca
au
usse
e a
a ffiirre
e h
ha
azza
arrd
d w
wh
hiicch
h cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y..
••
D
Do
o N
NO
OT
T cco
on
nn
ne
ecctt g
ga
ass p
piip
piin
ng
g tto
o tth
hiiss u
un
niitt u
un
nttiill a
a ssu
up
pp
plly
y lliin
ne
e p
prre
essssu
urre
e// lle
ea
akk tte
esstt h
ha
ass
b
be
ee
en
n cco
om
mp
plle
ette
ed
d..
••
D
Do
o N
NO
OT
T rre
elly
y o
on
n a
a g
ga
ass ssh
hu
utto
offff v
va
allv
ve
e tto
o iisso
olla
atte
e tth
he
e u
un
niitt w
wh
hiille
e cco
on
nd
du
uccttiin
ng
g g
ga
ass
p
prre
essssu
urre
e//lle
ea
akk tte
essttss.. T
Th
he
esse
e v
va
allv
ve
ess m
ma
ay
y n
no
ott b
be
e cco
om
mp
plle
ette
elly
y ssh
hu
utto
offff,, e
ex
xp
po
ossiin
ng
g tth
he
e u
un
niitt
g
ga
ass v
va
allv
ve
e tto
o e
ex
xcce
essssiiv
ve
e p
prre
essssu
urre
e..
••
D
Do
o n
no
ott o
ov
ve
err--ttiig
gh
htte
en
n tth
he
e iin
nlle
ett g
ga
ass p
piip
piin
ng
g a
att u
un
niitt g
ga
ass v
va
allv
ve
e..
W
WA
AR
RN
NIIN
NG
G
E
Ex
xp
pllo
ossiio
on
n H
Ha
azza
arrd
d!!
F
Fa
aiillu
urre
e tto
o ffo
ollllo
ow
w ssa
affe
e lle
ea
akk tte
esstt p
prro
occe
ed
du
urre
ess b
be
ello
ow
w cco
ou
ulld
d rre
essu
ulltt iin
n d
de
ea
atth
h o
orr sse
erriio
ou
uss iin
njju
urry
y o
orr
e
eq
qu
uiip
pm
me
en
ntt o
orr p
prro
op
pe
errtty
y--o
on
nlly
y--d
da
am
ma
ag
ge
e..
N
Ne
ev
ve
err u
usse
e a
an
n o
op
pe
en
n fflla
am
me
e tto
o d
de
ette
ecctt g
ga
ass lle
ea
akkss.. U
Usse
e a
a lle
ea
akk tte
esstt sso
ollu
uttiio
on
n ffo
orr lle
ea
akk tte
essttiin
ng
g..
The gas line should be supported so that no strain is placed on the unit. Pipe compounds which
are not soluble to liquid petroleum gases must be used on threaded joints.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas supply piping system by closing the individual
manual shutoff valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 psig (3.5 kPa).
For additional gas piping information, including pipe sizing and drip leg installation, refer to
Indoor Gas-Fired Duct Furnace Installation and Service Manual.
For additional piping information, refer to the National Fuel Gas Code Z233.1 (latest edition).
IIm
mp
po
orrtta
an
ntt:: If the gas duct furnace is to be fired with LP gas, consult local LP gas dealer for piping
size information.
IIm
mp
po
orrtta
an
ntt:: Unit installation for use with propane (bottled) gas must be made by a qualified LP
gas dealer or installer. He will insure proper joint compounds are used for making
pipe connections; that air is purged from lines; that a thorough test is made for leaks
before operating the unit; and that it is properly connected to propane gas supply
system.
Before any connection is made to an existing line supplying other gas appliances, contact the
local gas company to make certain that the existing line is of adequate size to handle the
combined load.
Check all connections for leaks with soap solution.
Modulating Gas Control (Optional)*
•
E
Elle
eccttrro
on
niicc
–
On units equipped with electronic modulating control, follow control manufacturer’s
installation instructions for sensing of outlet air temperature.
–
*
*A
Allsso
o rre
effe
err tto
o tth
he
e IIn
nd
do
oo
orr D
Du
ucctt F
Fu
urrn
na
acce
e IIn
nsstta
alllla
attiio
on
n M
Ma
an
nu
ua
all ssu
up
pp
plliie
ed
d w
wiitth
h y
yo
ou
urr u
un
niitt..
IIn
nsstta
alllla
attiio
on
n
Summary of Contents for GGAA
Page 35: ...MUA SVX005B EN 35 Figure 12 Blower RPM Adjustment M Ma ai in nt te en na an nc ce e ...
Page 47: ...MUA SVX005B EN 47 Motor Electric Data Table 7 Full Load Current in Amperes ...
Page 50: ...50 MUA SVX005B EN Coil Cabinet Dimensional Data Figure 13 Coil Cabinet Dimensional Data ...
Page 57: ...MUA SVX005B EN 57 Gas Equipment Start Up ...
Page 58: ...58 MUA SVX005B EN N No ot te es s ...