Trane CleanEffects 32-5038-10 User'S Information Manual Download Page 6

Numbers in [brackets] are for 50 Hz international systems. 

32-5038-10

User’s Information

The air cleaner is factory set to notify the home owner to 
clean the PRE-FILTER every two months [10 weeks] of 
actual run time of the air cleaner.  This notification can 
be changed by the installer/home owner to 1 month or 
3 months [5 to 15 weeks] depending on the conditions 
in the home (pets, smokers, etc.).   Please see “SET-UP 
MODE” (Page 9) to change the factory settings.  

1.  Using a vacuum hose, vacuum in even strokes 

across the length of the PRE-FILTER.   After 
vacuuming the entire PRE-FILTER using 
even strokes going in one direction, repeat 
the process using even strokes going in the 
opposite direction as shown in Figure 7. 

NOTE:  Do NOT replace the plastic PRE-FILTER with 

a metal type PRE-FILTER. A metal PRE-FILTER will 

cause reduction in efficiency and potential failure of 

the electronics in the air cleaner.

COLLECTION CELLS
The clean/dirty LED light bar indicator will illuminate as 
the system cleans the air.  The LED lights will progress 
from green to yellow and then to red.  When the last red 
indicator is flashing, it is time to clean the COLLECTION 
CELLS (see Figure 6).  The air cleaner is factory set 
to notify the home owner to clean the COLLECTION 
CELLS  every six months [31 weeks] of actual run time 
of the air cleaner.  This notification can be changed 
by the installer/home owner to 2 months, 4 months, 6 
months, or 9 months [10, 20, 31 or 46 weeks] depending 
on the conditions in the home (pets, smokers, etc.).   
Please see “SET-UP MODE” (Page 9) to change the 
factory settings. 

Fig. 7

VACUUM CLEANING

Vacuuming is the preferred method to clean the PRE-
FILTER and COLLECTION CELLS.  It is recommended 
that the PRE-FILTER and the COLLECTION CELLS 
be vacuumed outside the home to ensure particles on 
the filters are not reintroduced into the air.  Persons 
highly sensitive to the collected particles should wear 
appropriate respiratory protection while cleaning. 

PRE-FILTER –
It is time to clean the PRE-FILTER when the red “PRE-
FILTER” light (shown in Figure 6) is illuminated. 

Fig. 6

PRE-FILTER

RESET

CLEAN

PRE-FILTER

Flashing red light indicates 
that it is time to clean the 
COLLECTION CELLS

Red light indicates that it is 
time to clean the PRE-
FILTER

Summary of Contents for CleanEffects 32-5038-10

Page 1: ...ost advanced innovative and effective whole house air filtration system on the market today It is designed to deliver what we call TRANE AirTM throughout your home It delivers air that is meticulously filtered and cleaned of up to 99 98 of allergens to provide maximum comfort You and your family can breathe easier than ever before Trane 2013 32 5038 10 ...

Page 2: ...24 volt system When installed as part of a Communicating System in which the indoor unit furnace or air handler outdoor unit air conditioner or heat pump and comfort control are equipped with our exclusive Communicating technology your system performs a continuous loop of system diagnostics and data output The Communicating System monitors itself and quickly identifies any operational faults autom...

Page 3: ...nvert the 24 Volt AC to the high voltage direct cur rent required to power the FIELD CHARGER and COLLEC TION CELLS Allows access to the COLLECTION CELLS FIELD CHARGER and PRE FILTER 6 24 VOLT POWER CABLE DISPLAY FEATURES The air cleaner display Fig 2 has the following functions LED and PRE FILTER lights display the operating status of the air cleaner indicating when to clean the PRE FILTER or COLL...

Page 4: ... air cleaner may make a slight sound as the air passes through it and is cleaned In some applications you may notice this sound coming from the return air vent s If desired this sound level can be reduced with minimal impact on air cleaning efficiency by reducing the power setting of the FIELD CHARGER in the SET UP mode see pages 9 10 CAUTION Before cleaning the coil or ducts in the air handler or...

Page 5: ...CELLS which allows the COLLECTION CELLS to work more efficiently 1 Turn the air conditioning system off at the Comfort Control thermostat WARNING High Voltage is present within the air cleaner for operation Before removing the Power Door turn the power off and wait at least 15 seconds to allow voltage to discharge Failure to follow instructions could result in death or serious personal injury 2 Tu...

Page 6: ...hts will progress from green to yellow and then to red When the last red indicator is flashing it is time to clean the COLLECTION CELLS see Figure 6 The air cleaner is factory set to notify the home owner to clean the COLLECTION CELLS every six months 31 weeks of actual run time of the air cleaner This notification can be changed by the installer home owner to 2 months 4 months 6 months or 9 month...

Page 7: ...r arrow on the PREFILTER is pointing in the same direction as the AIRFLOW indicator arrow on the air cleaner cabi net 2 Reinstall the COLLECTION CELLS into the air cleaner Ensure the handles on both of the COL LECTION CELLS are folded flat Handles Fold Flat 3 Replace the power door onto the air cleaner To install the door follow the instructions in Figures 11 14 below 1 Using a vacuum hose vacuum ...

Page 8: ...BEFORE INSTALLING Fig 16 Rotate latches to secure door Fig 15 Fig 13 Rotate door to closed position Ensure ends of door overlap cabinet See detail Cabinet Edge Plug Power Cord in here Power Button Amber Light Fig 14 The whole house air cleaner can be connected in one of two modes of operation either a 24 V mode or a communicating mode To know how the whole house air cleaner is set up reference Fig...

Page 9: ...he YELLOW LED lights are used to set the COLLEC TION CELLS cleaning interval for two four six or nine months 10 20 31 or 46 weeks The number of illumi nated YELLOW LED lights indicates the current setting as shown in Figure 19 The factory setting is 6 months 31 weeks of run time G1 G2 G3 Y1 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY Power Level Collection Cell Pre Filter Factory settings FIELD CHARGER Power Ma...

Page 10: ... R2 R3 Y2 CLEAN DIRTY G1 G2 G3 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY Y1 G1 G2 G3 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY Y1 Y1 G1 G2 G3 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY Y1 Two Months 10 Weeks Four Months 20 Weeks Six Months 31 Weeks Nine Months 46 Weeks Fig 21 G1 G2 G3 Y1 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY G1 G2 G3 Y1 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY G1 G2 G3 Y1 Y3 Y4 R1 R2 R3 Y2 CLEAN DIRTY Minimum Medium Maximum Fig 22 Fact...

Page 11: ...e POWER button for three seconds The LED s will remain on until the voltage has discharged and it is safe to remove the door This requires approximately 15 seconds Do not remove the door until all the lights are off 2 Clean both the PREFILTER and the COLLECTION CELLS to insure no large material is trapped in the filters and causing the fault See pages 4 9 for cleaning information NOTE If collectio...

Page 12: ...s a policy of continuous product and product data improvement it reserves the right to change design and specifications without notice Trane 6200 Troup Highway Tyler TX 75707 For more information contact your local dealer distributor ...

Reviews: