32-5038-10
Numbers in [brackets] are for 50 Hz international systems.
3
User’s Information
Figure 1. COMPONENTS OF THE TRANE CLEANEFFECTS
TM
1) PRE-FILTER
- Traps large particles such as hair and lint
before they can enter the COLLECTION CELL section.
2) FIELD CHARGER
- Charges the contaminants.
Only to
be removed, cleaned or serviced by a qualified techni-
cian.
3) COLLECTION CELL (2)
- Removes and collects very
small impuri ties from the air.
4) CABINET
- Mounts between the furnace or air handler
and return air duct work and houses the COLLECTION
CELLS, FIELD CHARGER and PRE-FILTER.
3
2
4
5
1
3
6
5) POWER DOOR
- The solid state power supply components
that convert the 24 Volt AC to the high-voltage, direct cur-
rent required to power the FIELD CHARGER and COLLEC-
TION CELLS. Allows access to the COLLECTION CELLS,
FIELD CHARGER and PRE-FILTER.
6) 24 VOLT POWER CABLE
DISPLAY FEATURES
The air cleaner display (Fig. 2) has the following
functions:
LED and PRE-FILTER lights display the operating status
of the air cleaner, indicating when to clean the PRE-
FILTER or COLLECTION CELLS.
The LED display is also used in the SET-UP mode, see
page 9.
1 2 3
LED's
POWER
PRE-FILTER
RESET
PRE-FILTER
RESET
CLEAN
DIRTY
Fig. 1
Fig. 2
NOTE: International (50 Hz) Timings:
Due to differences in electrical systems outside
the United States, customers with 50 Hz electrical
systems will need to be aware of minor differences
in the timings shown in this guide. 50 Hz timings
will appear in [brackets] following the standard 60
hz timings.